{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,3,14]],"date-time":"2024-03-14T00:05:13Z","timestamp":1710374713218},"reference-count":16,"publisher":"Oxford University Press (OUP)","issue":"6","license":[{"start":{"date-parts":[[1991,6,1]],"date-time":"1991-06-01T00:00:00Z","timestamp":675734400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1991,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>An automated image comparison procedure was developed to optimize the precision of bone mineral density measurements by dual-photon absorptiometry. Changed acquisition conditions cause differences between two images to be compared. Alignment of one image with respect to the other is performed by a transformation that involves a rotation, a horizontal or vertical shift, and a correction for the soft tissue level. The best possible transformation is found in a stepwise search, guided by initial estimations of its parameters. After optimum transformation of one image, the region of interest of the other image is applied to both of them. Duplicate measurements of 9 patients and 15 normal subjects were performed; automated analysis yielded improved precision with respect to manual analysis. The coefficient of variation (CV) was also computed. The CV for automated analysis was 2.00% for patients and 1.04% for normal subjects compared to 3.55 and 1.93%, respectively, for manual analysis. For phantoms, the precision was 2.67% for manual analysis and 0.49% for automated analysis.<\/jats:p>","DOI":"10.1002\/jbmr.5650060608","type":"journal-article","created":{"date-parts":[[2010,2,3]],"date-time":"2010-02-03T17:44:29Z","timestamp":1265219069000},"page":"575-581","source":"Crossref","is-referenced-by-count":3,"title":["Automated comparison of dual-photon absorptiometric studies of the lumbar spine"],"prefix":"10.1093","volume":"6","author":[{"given":"Luis F.","family":"Verheij","sequence":"first","affiliation":[{"name":"Division of Nuclear Medicine, Department of Diagnostic Radiology, University Hospital Leiden, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacobus A. K.","family":"Blokland","sequence":"additional","affiliation":[{"name":"Division of Nuclear Medicine, Department of Diagnostic Radiology, University Hospital Leiden, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Socrates E.","family":"Papapoulos","sequence":"additional","affiliation":[{"name":"Clinical Investigation Unit, Department of Endocrinology, University Hospital Leiden, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olav L. M.","family":"Bijvoet","sequence":"additional","affiliation":[{"name":"Clinical Investigation Unit, Department of Endocrinology, University Hospital Leiden, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ernest K. J.","family":"Pauwels","sequence":"additional","affiliation":[{"name":"Division of Nuclear Medicine, Department of Diagnostic Radiology, University Hospital Leiden, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[1991,6,1]]},"reference":[{"key":"2024012712562417800_bib1","first-page":"1","article-title":"Clinical indications for bone mass measurements. A report from the scientific advisory board of the National Osteoporosis Foundation","volume":"4","author":"Johnston","year":"1989","journal-title":"J Bone Miner Res"},{"key":"2024012712562417800_bib2","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/0169-6009(88)90003-7","article-title":"Accelerated vertebral bone loss in relation to the menopause: A cross-sectional study on lumbar bone density in 286 women of 46 to 55 years of age","volume":"5","author":"Elders","year":"1988","journal-title":"Bone Miner"},{"key":"2024012712562417800_bib3","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1172\/JCI112462","article-title":"Rates of bone loss in the appendicular and axial skeletons of women: Evidence of substantial vertebral bone loss before menopause","volume":"77","author":"Riggs","year":"1986","journal-title":"J Clin Invest"},{"key":"2024012712562417800_bib4","first-page":"1774","article-title":"Limited precision of dual photon absorptiometry by variations in the soft tissue background","volume":"31","author":"Valkema","year":"1990","journal-title":"J Nucl Med"},{"key":"2024012712562417800_bib5","first-page":"1362","article-title":"Precision of dual photon absorptiometry measurements","volume":"27","author":"LeBlanc","year":"1986","journal-title":"J Nucl Med"},{"key":"2024012712562417800_bib6","first-page":"1","volume-title":"Information Processing in Medical Imaging","author":"Venot","year":"1984"},{"key":"2024012712562417800_bib7","first-page":"1337","article-title":"Automated comparison of scintigraphic images","volume":"27","author":"Venot","year":"1986","journal-title":"J Nucl Med"},{"key":"2024012712562417800_bib8","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1109\/42.14512","article-title":"An automated system for the registration and comparison of photographic images in medicine","volume":"7","author":"Venot","year":"1988","journal-title":"IEEE Trans Med Imaging"},{"key":"2024012712562417800_bib9","first-page":"62","volume-title":"BMC-LAB 22a Users Handbook","author":"Anonymous","year":"1983"},{"key":"2024012712562417800_bib10","doi-asserted-by":"crossref","DOI":"10.1109\/42.79478","article-title":"Automatic region of interest determination in dual photon absorptiometry of the lumbar spine","volume":"10","author":"Verheij","year":"1991","journal-title":"IEEE Trans Med Imaging"},{"key":"2024012712562417800_bib11","first-page":"1156","article-title":"Dual-energy x-ray absorptiometry: A precise method of measuring bone mineral density in the lumbar spine","volume":"31","author":"Hansen","year":"1990","journal-title":"J Nucl Med"},{"key":"2024012712562417800_bib12","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1007\/BF00253791","article-title":"Precision of dual photon absorptiometry measurements: Comparison of three different methods of selection of the region of interest","volume":"15","author":"Valkema","year":"1989","journal-title":"Eur J Nucl Med"},{"key":"2024012712562417800_bib13","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1016\/S0025-6196(12)65502-5","article-title":"Comparison of dual-energy x-ray absorptiometry and dual photon absorptiometry for bone mineral measurements of the spine","volume":"63","author":"Wahner","year":"1988","journal-title":"Mayo Clin Proc"},{"key":"2024012712562417800_bib14","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1148\/radiology.170.1.2909085","article-title":"Quantitative dual-energy radiographic absorptiometry of the lumbar spine: In vivo comparison with dual photon absorptiometry","volume":"170","author":"Borders","year":"1989","journal-title":"Radiology"},{"key":"2024012712562417800_bib15","first-page":"734","volume-title":"Manual of Remote Sensing","author":"Billingsley","year":"1983","edition":"2nd ed."},{"key":"2024012712562417800_bib16","first-page":"113","volume-title":"Digital Image Processing","author":"Pratt","year":"1978"}],"container-title":["Journal of Bone and Mineral Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjbmr.5650060608","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/jbmr\/article-pdf\/6\/6\/575\/56432460\/5650060608.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jbmr\/article-pdf\/6\/6\/575\/56432460\/5650060608.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,13]],"date-time":"2024-03-13T14:52:34Z","timestamp":1710341554000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jbmr\/article\/6\/6\/575-581\/7502421"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1991,6,1]]},"references-count":16,"journal-issue":{"issue":"6","published-online":{"date-parts":[[1991,6,1]]},"published-print":{"date-parts":[[1991,6,1]]}},"URL":"https:\/\/doi.org\/10.1002\/jbmr.5650060608","relation":{},"ISSN":["0884-0431","1523-4681"],"issn-type":[{"value":"0884-0431","type":"print"},{"value":"1523-4681","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[1991,6,1]]},"published":{"date-parts":[[1991,6,1]]}}}