{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,11,13]],"date-time":"2023-11-13T00:07:00Z","timestamp":1699834020084},"reference-count":14,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2005,12,1]],"date-time":"2005-12-01T00:00:00Z","timestamp":1133395200000},"content-version":"vor","delay-in-days":11233,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J of Clinical Ultrasound"],"published-print":{"date-parts":[[1975,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A new transmission ultrasound camera system has provided focused images in real time through the abdomen of adult volunteers at average incident sound intensity levels of less than 1 mW\/cm<jats:sup>2<\/jats:sup>. The camera uses a unique acousto\u2010mechanical lens\/deflection system and a linear array of piezoelectric transducers to detect the ultrasound image. Bony structures and costal cartilages were clearly seen. The colon was regularly seen and the kidney could be outlined in several subjects. The stomach and duodenal bulb were demonstrated and peristalsis was observed using a barium contrast material. The camera has the potential of extending the use of ultrasound in clinical medicine providing an ultrasound soft tissue imaging system analogous to an x\u2010ray fluoroscope. The need for further clinical evaluation and research to improve the images is emphasized.<\/jats:p>","DOI":"10.1002\/jcu.1870030105","type":"journal-article","created":{"date-parts":[[2007,2,27]],"date-time":"2007-02-27T23:08:42Z","timestamp":1172617722000},"page":"17-22","source":"Crossref","is-referenced-by-count":7,"title":["Real\u2010time imaging with a new ultrasonic camera: Part II, preliminary studies in normal adults"],"prefix":"10.1002","volume":"3","author":[{"given":"Leslie M.","family":"Zatz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin J.","family":"Lipton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth W.","family":"Marich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip S.","family":"Green","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joe R.","family":"Suarez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Albert","family":"Macovski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,12]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4757-0827-1_27"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1002\/jcu.1870030104"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1148\/109.2.417"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4757-0827-1_28"},{"key":"e_1_2_1_6_2","first-page":"181","article-title":"Medical imaging capability of liquid surface ultrasonic holography","volume":"35","author":"Curtin HR","year":"1972","journal-title":"Proceedings of the Society of Photo\u2010Optical Instrumentation Engineers"},{"key":"e_1_2_1_7_2","unstructured":"HolbrookeDR McCurryEM RichardV andShibataH:Through\u2010transmission ultrasonic imaging of intrauterine and fetal structures using acoustical holography. Presented at the 2nd World Congress of Ultrasonics in Medicine Rotterdam Netherlands June 6 1973."},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-197310000-00017"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4757-0827-1_23"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4757-0827-1_24"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1148\/102.1.191"},{"key":"e_1_2_1_12_2","first-page":"953","article-title":"Detection of tumors in soft tissues ultrasonic holography","volume":"128","author":"Weiss L","year":"1969","journal-title":"Surg Gynec Obstet"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4615-8210-6_10"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4757-0827-1_21"},{"key":"e_1_2_1_15_2","first-page":"230","article-title":"Ultrasonic transmission imaging using gaussian noise source (Abst.)","volume":"2","author":"Fry FJ","year":"1974","journal-title":"J Clin Ultrasound"}],"container-title":["Journal of Clinical Ultrasound"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjcu.1870030105","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jcu.1870030105","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,12]],"date-time":"2023-11-12T10:07:40Z","timestamp":1699783660000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jcu.1870030105"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1975,3]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1975,3]]}},"alternative-id":["10.1002\/jcu.1870030105"],"URL":"https:\/\/doi.org\/10.1002\/jcu.1870030105","archive":["Portico"],"relation":{},"ISSN":["0091-2751","1097-0096"],"issn-type":[{"value":"0091-2751","type":"print"},{"value":"1097-0096","type":"electronic"}],"subject":[],"published":{"date-parts":[[1975,3]]}}}