{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T03:40:53Z","timestamp":1738294853342,"version":"3.35.0"},"reference-count":16,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2008,7,18]],"date-time":"2008-07-18T00:00:00Z","timestamp":1216339200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J of Clinical Ultrasound"],"published-print":{"date-parts":[[2008,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose.<\/jats:title><jats:p>To explore the feasability of imaging lung masses with a novel endobronchial linear\u2010array transducer.<\/jats:p><\/jats:sec><jats:sec><jats:title>Method.<\/jats:title><jats:p>We used a linear\u2010array transducer of 7 F (2.3 mm in diameter) operating at a center frequency of 10 MHz for endobronchial imaging. We used the probe in 20 subjects with suspected lung cancer to identify and measure the tumor; to asses the tumor's sonographic characteristics, bronchial wall invasion, and presence of lymph nodes; to guide a transbronchial needle aspiration (TBNA); and to evaluate potential side effects.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results.<\/jats:title><jats:p>In all patients, the tumor was identified and the relationship with the bronchial wall correctly evaluated through the depiction of a 3\u2010layer wall pattern. Bronchial wall invasion was suspected in 5 patients, small adjacent lymph nodes were detected in 3 patients, and a small pleural effusion was observed close to the lung lesion in 2 patients. The linear\u2010array probe allowed the guidance of successful TBNA with no complications.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion.<\/jats:title><jats:p>This feasibility study shows that the prototype probe can be used to depict pulmonary lesions and to guide biopsy nodes. Larger series are needed to validate its usefulness in clinical work\u2010ups and patients management. \u00a9 2008 Wiley Periodicals, Inc. J Clin Ultrasound, 2008<\/jats:p><\/jats:sec>","DOI":"10.1002\/jcu.20512","type":"journal-article","created":{"date-parts":[[2008,7,18]],"date-time":"2008-07-18T21:00:26Z","timestamp":1216414826000},"page":"457-461","source":"Crossref","is-referenced-by-count":1,"title":["Feasability of human endobronchial imaging with a linear\u2010array ultrasound catheter"],"prefix":"10.1002","volume":"36","author":[{"given":"Fran\u00e7ois","family":"Tranquart","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peggy","family":"Palanchon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Odile","family":"Clad\u00e9","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aurore","family":"Bleuzen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominique","family":"Dinet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pascal","family":"Magro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrice","family":"Diot","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,7,18]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-001-1185-1"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0929-8266(99)00043-9"},{"key":"e_1_2_1_4_2","doi-asserted-by":"crossref","unstructured":"LacazeE MichauS MauchampP.20\u2010MHz ultrasound array for medical imaging: from design to image evaluation. Proceedings of the 2001 IEEE Ultrasonics Symposium2001;2:1139.","DOI":"10.1109\/ULTSYM.2001.991919"},{"volume-title":"Echographie en pratique gyn\u00e9cologique","year":"2007","author":"Ardaens Y","key":"e_1_2_1_5_2"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1136\/thx.47.7.565"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(00)00372-9"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1159\/000070066"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.mcp.0000166492.69788.e3"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1159\/000091528"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0169-5002(01)00353-1"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.121.5.1498"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.lungcan.2005.07.013"},{"key":"e_1_2_1_14_2","doi-asserted-by":"crossref","unstructured":"Clad\u00e9O TranquartF PalanchonP et al.Development and clinical evaluation of a 10MHz ultrasound linear array catheter for endobronchial imaging. Proceedings of the 2005 IEEE Ultrasonics Symposium2005;1\u20134:653.","DOI":"10.1109\/ULTSYM.2005.1602937"},{"key":"e_1_2_1_15_2","doi-asserted-by":"crossref","unstructured":"Clad\u00e9O FelixN LacazeE.Linear and curved array with advanced electroacoustic and acoustic properties. Proceedings of the 2002 IEEE Ultrasonics Symposium2002;2:1127.","DOI":"10.1109\/ULTSYM.2002.1192492"},{"key":"e_1_2_1_16_2","doi-asserted-by":"crossref","unstructured":"FelixN RatsimandresyL DufaitR.High bandwidth high density arrays for advanced ultrasound imaging. Proceedings of the 2001 IEEE Ultrasonics Symposium2001;2:1123.","DOI":"10.1109\/ULTSYM.2001.991916"},{"key":"e_1_2_1_17_2","unstructured":"American Institute of Ultrasound in Medicine. Guidelines for cleaning and preparing endocavitary ultrasound transducers between patients. June2005. Available at:www.aium.org\/publications\/statements\/_statementselected.asp?statement=27."}],"container-title":["Journal of Clinical Ultrasound"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjcu.20512","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jcu.20512","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T02:50:02Z","timestamp":1738291802000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jcu.20512"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,7,18]]},"references-count":16,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2008,10]]}},"alternative-id":["10.1002\/jcu.20512"],"URL":"https:\/\/doi.org\/10.1002\/jcu.20512","archive":["Portico"],"relation":{},"ISSN":["0091-2751","1097-0096"],"issn-type":[{"type":"print","value":"0091-2751"},{"type":"electronic","value":"1097-0096"}],"subject":[],"published":{"date-parts":[[2008,7,18]]}}}