{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T20:58:18Z","timestamp":1784667498229,"version":"3.55.0"},"reference-count":37,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2020,6,26]],"date-time":"2020-06-26T00:00:00Z","timestamp":1593129600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2020,6,26]],"date-time":"2020-06-26T00:00:00Z","timestamp":1593129600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100002966","name":"Cumhuriyet \u00dcniversitesi","doi-asserted-by":"publisher","award":["DIS\u2010207"],"award-info":[{"award-number":["DIS\u2010207"]}],"id":[{"id":"10.13039\/501100002966","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["analyticalsciencejournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Microscopy Res &amp;amp; Technique"],"published-print":{"date-parts":[[2020,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Electronic apex locators (EALs), cone\u2010beam computed tomography (CBCT), and radiovisiography (RVG) claim to determine of working length (WL) in primary molar teeth. To evaluate the accuracy of WL determination by using three EALs, RVG, and CBCT imaging in extracted human primary molar teeth with\/without root resorption. Twenty extracted primary molar teeth with resorption and 20 extracted primary molar teeth without resorption were used. After measuring actual lengths (AL) (Group 1), the electronic WL measurements were performed by using three different EALs [COXO C Smart\u20101 Pro (Group 2), iPex (Group 3), and Apex ID (Group 4)]. Two different image sets were obtained as follows: CBCT imaging (Group 5) and RVG (Group 6). AL measurements performed with an endodontic measuring ruler and compared with the EAL, CBCT, and RVG image measurements. For all groups, there were no significant differences between the teeth with resorption and without. There were no significant differences in measuring methods from AL and between the methods used (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&gt;\u2009.05). When electronic and radiographic method were compared in different frequency ranges, there was no statistically significant difference (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&gt;\u2009.05). This study showed that EALs, CBCT, and RVG have high accuracy in primary molar teeth both with resorption and without root resorption and can be used for determining WL.\n                  <\/jats:p>","DOI":"10.1002\/jemt.23524","type":"journal-article","created":{"date-parts":[[2020,6,27]],"date-time":"2020-06-27T05:25:55Z","timestamp":1593235555000},"page":"1330-1335","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Evaluation of the accuracy of electronic apex locators, cone\u2010beam computed tomography, and radiovisiography in primary teeth: An in vitro study"],"prefix":"10.1002","volume":"83","author":[{"given":"Mevlut","family":"Kayabasi","sequence":"first","affiliation":[{"name":"Department of Pediatric Dentistry, Faculty of Dentistry Cumhuriyet University  Sivas Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7797-0932","authenticated-orcid":false,"given":"Fatih","family":"Oznurhan","sequence":"additional","affiliation":[{"name":"Department of Pediatric Dentistry, Faculty of Dentistry Cumhuriyet University  Sivas Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2020,6,26]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2010.01839.x"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.5005\/jp-journals-10005-1403"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s40368-013-0011-1"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2010.04.006"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1179\/1465313312Y.0000000041"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.1984.tb00404.x"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1590\/S0103-64402008000200005"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-31466-2"},{"issue":"9","key":"e_1_2_8_10_1","first-page":"1393","article-title":"Use of cone beam computed tomography in endodontics 2015 update","volume":"41","author":"Fayad M. I.","year":"2015","journal-title":"Journal of Endodontics"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2004.00835.x"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2007.05.009"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/ipd.12076"},{"key":"e_1_2_8_14_1","first-page":"252","article-title":"Measurements of the primary teeth","volume":"26","author":"Ireland R.","year":"1959","journal-title":"Journal of Dentistry for Children"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/ipd.12250"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2014.12.014"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr\/12615645"},{"issue":"6","key":"e_1_2_8_18_1","first-page":"414","article-title":"Electronic apex locator: A useful tool for root canal treatment in the primary dentition","volume":"63","author":"Katz A.","year":"1996","journal-title":"ASDC Journal of Dentistry for Children"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cden.2003.10.005"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2591.2002.00535.x"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/iej.12140"},{"key":"e_1_2_8_22_1","first-page":"1","article-title":"Principles of cone beam computed tomography. 3D imaging in endodontics","volume":"1","author":"Mallya S. M.","year":"2016","journal-title":"Springer"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2591.2001.00400.x"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(07)80022-7"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2591.2009.01667.x"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2013.12.036"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/ajpa.1330210212"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.4103\/0970-4388.86371"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2017.03.039"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1111\/ipd.12128"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0099-2399(98)80029-0"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2591.1998.00183.x"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2018.02.027"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.4103\/0970-4388.16883"},{"issue":"3","key":"e_1_2_8_35_1","first-page":"190","article-title":"Comparative evaluation of accuracy of three electronic apex locators in different simulated clinical conditions\u2010an invitro study","volume":"7","author":"Taneja S.","year":"2017","journal-title":"Annals of Medical and Health Sciences Research"},{"key":"e_1_2_8_36_1","volume-title":"Radiation risks from medical X\u2010ray examinations as a function of the age and sex of the patient","author":"Wall B.","year":"2011"},{"key":"e_1_2_8_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2005.10.044"},{"key":"e_1_2_8_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joen.2016.09.019"}],"container-title":["Microscopy Research and Technique"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjemt.23524","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jemt.23524","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jemt.23524","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jemt.23524","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T12:31:17Z","timestamp":1772973077000},"score":1,"resource":{"primary":{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/10.1002\/jemt.23524"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,26]]},"references-count":37,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2020,11]]}},"alternative-id":["10.1002\/jemt.23524"],"URL":"https:\/\/doi.org\/10.1002\/jemt.23524","archive":["Portico"],"relation":{},"ISSN":["1059-910X","1097-0029"],"issn-type":[{"value":"1059-910X","type":"print"},{"value":"1097-0029","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,26]]},"assertion":[{"value":"2019-04-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-05-20","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-06-26","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}