{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,17]],"date-time":"2025-10-17T00:29:05Z","timestamp":1760660945671,"version":"build-2065373602"},"reference-count":17,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2025,3,19]],"date-time":"2025-03-19T00:00:00Z","timestamp":1742342400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["analyticalsciencejournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Microscopy Res &amp;amp; Technique"],"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p>At the end of 2019, in the city of Wuhan, China, a new highly infectious coronavirus affecting the respiratory tract was announced. It was named SARS\u2010Cov2, causing deaths in the population. In the face of this global health emergency, many medical and protective supplies were quickly depleted, and some others of dubious quality emerged, including face masks for medical and population use. Given this uncertainty, this working group developed a complementary methodology to the wind tunnel, a technique usually used to measure the efficiency of particle passage in certified masks. A gravity\u2010feed airbrush gun operating at a pressure of 60 PSI was used for this purpose. Saline water at a concentration of 20% NaCl was used as the impact liquid on the face mask, and the deposition time was 1\u2009s, emulating the time of sneezing or coughing. The particles that passed through the face masks were deposited in sample holders for scanning electron microscopy (SEM), where a 0.8\u2009\u00d7\u20090.8\u2009cm slide was placed on their surface and the particles covered with an Au film deposited by sputtering. The sizes of the NaCl particles that were allowed to pass through the face masks were evaluated using field\u2010emission SEM (FSEM). It was found that at 0.5\u2009cm between the surface of the face mask and the deposit surface, the distance between the mask and airbrush nozzle was 2.5\u2009cm, and 1\u2009s deposits, the particles allowed to pass through the K95 and KN95 masks were 85% and 88%, respectively, in the range from 0.2 to 1 to 0\u2009\u03bcm, in both cases, the number of particles deposited per unit area was low, 0.1 particles\/\u03bcm<jats:sup>2<\/jats:sup>. Based on this methodology, some face masks used daily by the population were evaluated, finding that commercial two\u2010layer polypropylene masks allow NaCl particles larger than 5\u2009\u03bcm to pass through, while in the commercial three\u2010layer face mask the NaCl particle size was 2\u2009\u03bcm in order.<\/jats:p>","DOI":"10.1002\/jemt.24857","type":"journal-article","created":{"date-parts":[[2025,3,20]],"date-time":"2025-03-20T02:30:28Z","timestamp":1742437828000},"page":"2250-2258","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The Development of an Alternative Methodology to Measure the Particle Size Allowed Passing Through Face Masks Using a Scanning Electron Microscopy"],"prefix":"10.1002","volume":"88","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5710-4914","authenticated-orcid":false,"given":"J.","family":"Arenas\u2010Alatorre","sequence":"first","affiliation":[{"name":"Instituto de F\u00edsica UNAM, Circuito de la Investigaci\u00f3n Cient\u00edfica S\/N, Ciudad Universitaria, Delegaci\u00f3n Coyoac\u00e1n  Mexico City Mexico"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. Tehuacanero","family":"Cuapa","sequence":"additional","affiliation":[{"name":"Instituto de F\u00edsica UNAM, Circuito de la Investigaci\u00f3n Cient\u00edfica S\/N, Ciudad Universitaria, Delegaci\u00f3n Coyoac\u00e1n  Mexico City Mexico"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Maga\u00f1a\u2010Zavala","sequence":"additional","affiliation":[{"name":"Instituto de F\u00edsica UNAM, Circuito de la Investigaci\u00f3n Cient\u00edfica S\/N, Ciudad Universitaria, Delegaci\u00f3n Coyoac\u00e1n  Mexico City Mexico"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cecilia","family":"Noguez","sequence":"additional","affiliation":[{"name":"Instituto de F\u00edsica UNAM, Circuito de la Investigaci\u00f3n Cient\u00edfica S\/N, Ciudad Universitaria, Delegaci\u00f3n Coyoac\u00e1n  Mexico City Mexico"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,3,19]]},"reference":[{"key":"e_1_2_9_2_1","unstructured":"3M Science Aplied to Life.2021.\u201cComparison of FFP2 KN95 and N95 Filtering Facepiece Respirator Classes.\u201dTechnical Bulletin.https:\/\/multimedia.3m.com\/mws\/media\/1791500O\/comparison\u2010ffp2\u2010kn95\u2010n95\u2010filtering\u2010facepiece\u2010respirator\u2010classes\u2010tb.pdf."},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1080\/02786826.2024.2310542"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140\u20106736(20)30374\u20103"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijnurstu.2020.103629"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaerosci.2008.11.002"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.4491\/eer.2023.003"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.37745\/ijepr.13\/vol11n23239"},{"key":"e_1_2_9_9_1","doi-asserted-by":"crossref","unstructured":"Provenzano D. R. Y.James K.Mitic et\u00a0al.2020.\u201cAlternative Qualitative Fit Testing Method for N95 Equivalent Respirators in the Setting of Resource Scarcity at the George Washington University.\u201dmedRxiv Preprint. 1\u20138.https:\/\/doi.org\/10.1101\/2020.04.06.20055368.t.","DOI":"10.1101\/2020.04.06.20055368"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1080\/15459624.2010.515556"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1080\/15459624.2016.1225157"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S2213\u20102600(20)30245\u20109"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140\u20106736(20)31185\u20105"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.4209\/aaqr.220343"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1128\/aem.00045\u201022"},{"key":"e_1_2_9_16_1","doi-asserted-by":"crossref","unstructured":"Yim W. D.Cheng S.Patel R.Kui S.Meng Ying andJ. V.Jokerst.2020.\u201cAssessment of N95 and K95 Respirator Decontamination: Fiber Integrity Filtration Efficiency and Dipole Charge Density.\u201dmedRxiv Preprint.1\u201316.https:\/\/doi.org\/10.1101\/2020.07.07.20148551.","DOI":"10.1101\/2020.07.07.20148551"},{"volume-title":"Coronavirus Prevention Handboook: 101 Science\u2010Based Tips That Could Sabe Your Life","year":"2020","author":"Zhow Wang M. D.","key":"e_1_2_9_17_1"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa2001017"}],"container-title":["Microscopy Research and Technique"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jemt.24857","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T16:24:29Z","timestamp":1760631869000},"score":1,"resource":{"primary":{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/10.1002\/jemt.24857"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,19]]},"references-count":17,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025,8]]}},"alternative-id":["10.1002\/jemt.24857"],"URL":"https:\/\/doi.org\/10.1002\/jemt.24857","archive":["Portico"],"relation":{},"ISSN":["1059-910X","1097-0029"],"issn-type":[{"type":"print","value":"1059-910X"},{"type":"electronic","value":"1097-0029"}],"subject":[],"published":{"date-parts":[[2025,3,19]]},"assertion":[{"value":"2024-10-12","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-11","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-19","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}