{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T17:05:34Z","timestamp":1789491934171,"version":"build-2803163510"},"reference-count":23,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2024,7,24]],"date-time":"2024-07-24T00:00:00Z","timestamp":1721779200000},"content-version":"vor","delay-in-days":23,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2024,7,1]],"date-time":"2024-07-01T00:00:00Z","timestamp":1719792000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["esskajournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J. exp. orthop."],"published-print":{"date-parts":[[2024,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The purpose of this study was to compare the biomechanical properties of a latest generation all\u2010suture anchor repair device (ASARD) for meniscal repair with that of a latest generation PEEK\u2010cage anchor repair device (PCARD) in an experimental setting using cadaveric menisci.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Twenty\u2010six menisci were obtained from the knees of fresh body donors. Artificially created meniscal lesions were treated randomly, using a single stitch with either an ASARD or a PCARD. Cyclic biomechanical testing, utilising a universal material testing machine and following an established protocol, was carried out and load\u2010to\u2010failure (LTF), displacement, stiffness, and mode\u2010of\u2010failure (MOF) reported.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Mean LTF was found to be 61% higher in the ASARD group at 107.10\u2009N (standard deviation [SD], 42.34), compared to 65.86\u2009N (SD, 27.42) in the PCARD group with statistical significance (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.022). The ASARD exhibited a trend towards higher stiffness (10.35\u2009N; SD, 3.92 versus 7.78\u2009N; SD; 3.59) and higher displacement at cycles one, 100, and 499 (1.64, 3.27, and 4.17\u2009mm versus 0.93, 2.19, and 2.83\u2009mm) compared to the PCARD. Cheese wiring was the most common mode\u2010of\u2010failure in both groups (76.9%).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This study demonstrates that an ASARD shows a higher mean LTF than a PCARD when compared in an experimental biomechanical setting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of evidence<\/jats:title>\n                    <jats:p>Level III<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/jeo2.12110","type":"journal-article","created":{"date-parts":[[2024,7,25]],"date-time":"2024-07-25T01:41:58Z","timestamp":1721871718000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Superior load\u2010to\u2010failure in an all\u2010suture anchor system for all\u2010inside meniscal repair compared to a PEEK\u2010cage anchor system in an experimental cadaveric test setting"],"prefix":"10.1002","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9848-778X","authenticated-orcid":false,"given":"Lorenz","family":"Pichler","sequence":"first","affiliation":[{"name":"Department of Orthopaedics and Trauma Surgery Medical University of Vienna Vienna Austria"},{"name":"Center for Musculoskeletal Surgery Charit\u00e9 \u2013 University Medicine Berlin Berlin Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gyula","family":"Kiss","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Trauma Surgery Medical University of Vienna Vienna Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7007-5425","authenticated-orcid":false,"given":"Thomas","family":"Sator","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Trauma Surgery Medical University of Vienna Vienna Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Schuller","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Trauma Surgery Medical University of Vienna Vienna Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4139-7940","authenticated-orcid":false,"given":"Sam A.","family":"Kandathil","sequence":"additional","affiliation":[{"name":"Center for Anatomy and Cell Biology, Division of Anatomy Medical University of Vienna Vienna Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8097-5403","authenticated-orcid":false,"given":"Marcus","family":"Hofbauer","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Trauma Surgery Medical University of Vienna Vienna Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2801-3113","authenticated-orcid":false,"given":"Thomas","family":"Koch","sequence":"additional","affiliation":[{"name":"Research Group for Structural Polymers Technical University Vienna Vienna Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5194-9118","authenticated-orcid":false,"given":"Lena","family":"Hirtler","sequence":"additional","affiliation":[{"name":"Center for Anatomy and Cell Biology, Division of Anatomy Medical University of Vienna Vienna Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8698-8341","authenticated-orcid":false,"given":"Thomas","family":"Tiefenboeck","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Trauma Surgery Medical University of Vienna Vienna Austria"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,7,24]]},"reference":[{"key":"e_1_2_12_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546513495641"},{"key":"e_1_2_12_3_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465221107086"},{"key":"e_1_2_12_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.25021"},{"key":"e_1_2_12_5_1","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2001.19975"},{"key":"e_1_2_12_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200207000-00029236-245"},{"key":"e_1_2_12_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2008.06.021"},{"key":"e_1_2_12_8_1","unstructured":"Arthrex Orthopedic Research and Development. Biomechanical testing of meniscal repairs using the FiberStitch\u2122 Smith & Nephew FAST\u2010FIX\u2122 360 and Zimmer Biomet JuggerStitch\u2122 Implants.2020.https:\/\/www.arthrex.com\/resources\/LA1-000126-en-US\/biomechanical-testing-of-meniscal-repairs-using-the-fiberstitch-smith-and-nephew-fast-fix-360-and-zimmer-biomet-juggerstitch-implants?referringteam=knee"},{"key":"e_1_2_12_9_1","doi-asserted-by":"publisher","DOI":"10.1177\/2325967115579052"},{"key":"e_1_2_12_10_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546518755754"},{"key":"e_1_2_12_11_1","doi-asserted-by":"publisher","DOI":"10.3758\/BRM.41.4.1149"},{"key":"e_1_2_12_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(98)80210-8"},{"key":"e_1_2_12_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-012-1995-5"},{"key":"e_1_2_12_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-020-05847-3"},{"key":"e_1_2_12_15_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465211017514"},{"key":"e_1_2_12_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/0749-8063(91)90093-D"},{"key":"e_1_2_12_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/23259671211015674"},{"key":"e_1_2_12_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joca.2017.08.020"},{"key":"e_1_2_12_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.06.026"},{"key":"e_1_2_12_20_1","doi-asserted-by":"publisher","DOI":"10.1177\/036354652311583853635465231158385"},{"key":"e_1_2_12_21_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjsports-2020-102813"},{"key":"e_1_2_12_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2020.06.010"},{"key":"e_1_2_12_23_1","doi-asserted-by":"publisher","DOI":"10.1177\/1941738109334219"},{"key":"e_1_2_12_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/joa.12292"}],"container-title":["Journal of Experimental Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jeo2.12110","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jeo2.12110","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jeo2.12110","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T16:30:43Z","timestamp":1789489843000},"score":1,"resource":{"primary":{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/10.1002\/jeo2.12110"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7]]},"references-count":23,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,7]]}},"alternative-id":["10.1002\/jeo2.12110"],"URL":"https:\/\/doi.org\/10.1002\/jeo2.12110","archive":["Portico"],"relation":{},"ISSN":["2197-1153","2197-1153"],"issn-type":[{"value":"2197-1153","type":"print"},{"value":"2197-1153","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7]]},"assertion":[{"value":"2024-02-19","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-06-11","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-07-24","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e12110"}}