{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,19]],"date-time":"2026-05-19T12:06:59Z","timestamp":1779192419339,"version":"3.51.4"},"reference-count":26,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2025,7,18]],"date-time":"2025-07-18T00:00:00Z","timestamp":1752796800000},"content-version":"vor","delay-in-days":17,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["esskajournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J. exp. orthop."],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Radial meniscal tears significantly impact knee biomechanics and can lead to joint degeneration if untreated. While various suture techniques exist, no consensus has been reached on the optimal method. The hypothesis was that the double\u2010loop suture can significantly reduce displacement between tear segments and achieve a higher ultimate failure load than conventional techniques. This study aims to biomechanically compare conventional repair techniques to a novel double\u2010loop suture to enhance tensile strength, reduce displacement and improve meniscal repair outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Forty fresh\u2010frozen porcine menisci with full\u2010thickness radial tears were repaired using four techniques: double vertical, double horizontal, cross\u2010tie and double\u2010loop sutures. Biomechanical testing included cyclic loading (200 cycles, 5\u201319\u2009N) and ultimate failure load evaluation. Key outcomes measured were displacement after cyclic loading, failure load, and failure modes. A one\u2010way analysis of variance (ANOVA) was conducted to identify significant differences among groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Among the evaluated techniques, the double\u2010loop suture demonstrated the highest ultimate failure load (111.1\u2009\u00b1\u200917.3\u2009N,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.01). Displacement after cyclic loading was minimal across techniques, except for the double vertical suture, which showed significantly higher displacement. Knot breakage was the primary failure mode in conventional sutures, whereas the double\u2010loop suture also exhibited tissue cutting.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The double\u2010loop suture provides superior biomechanical performance, offering greater tensile strength and stability than conventional methods. Its simplicity and arthroscopic applicability highlight its potential for advanced meniscal repair. The double\u2010loop suture could be applied in the arthroscopic setting, improving the outcomes for treating radial tears. Further clinical studies are needed to confirm long\u2010term efficacy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence<\/jats:title>\n                    <jats:p>Level IV, cadaveric study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/jeo2.70366","type":"journal-article","created":{"date-parts":[[2025,7,18]],"date-time":"2025-07-18T13:08:14Z","timestamp":1752844094000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Double\u2010loop suture repair of radial meniscal tears provides favourable biomechanical performance compared to conventional repair techniques: A biomechanical study"],"prefix":"10.1002","volume":"12","author":[{"given":"Antonio","family":"Petillo","sequence":"first","affiliation":[{"name":"Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.) University of Palermo Palermo Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alessandro","family":"Di Rosa","sequence":"additional","affiliation":[{"name":"Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.) University of Palermo Palermo Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carmelo","family":"Burgio","sequence":"additional","affiliation":[{"name":"Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.) University of Palermo Palermo Italy"},{"name":"Adult Reconstruction and Joint Replacement Service Hospital for Special Surgery New York New York USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sofia","family":"Di Leonardo","sequence":"additional","affiliation":[{"name":"Department of Engineering University of Palermo Palermo Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gaetano","family":"Burriesci","sequence":"additional","affiliation":[{"name":"Department of Engineering University of Palermo Palermo Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8306-1869","authenticated-orcid":false,"given":"Francesco","family":"Bosco","sequence":"additional","affiliation":[{"name":"Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.) University of Palermo Palermo Italy"},{"name":"Department of Orthopaedics and Traumatology G.F. Ingrassia Hospital Unit Palermo Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ludovico","family":"Lucenti","sequence":"additional","affiliation":[{"name":"Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.) University of Palermo Palermo Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lawrence","family":"Camarda","sequence":"additional","affiliation":[{"name":"Department of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.) University of Palermo Palermo Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,7,18]]},"reference":[{"key":"e_1_2_12_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.aott.2018.07.002"},{"issue":"5","key":"e_1_2_12_3_1","first-page":"366","article-title":"Meniscal root tears: a decade of research on their relevant anatomy, biomechanics, diagnosis, and treatment","volume":"10","author":"Banovetz MT","year":"2022","journal-title":"Arch Bone Joint Surg"},{"key":"e_1_2_12_4_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546515591994"},{"key":"e_1_2_12_5_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465211015425"},{"key":"e_1_2_12_6_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-020-06078-2"},{"key":"e_1_2_12_7_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-020-00296-w"},{"key":"e_1_2_12_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546510382847"},{"key":"e_1_2_12_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2012.06.015"},{"key":"e_1_2_12_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12178-023-09831-5"},{"key":"e_1_2_12_11_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-019-0206-4"},{"key":"e_1_2_12_12_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546511424395"},{"key":"e_1_2_12_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.asmr.2021.03.002"},{"key":"e_1_2_12_14_1","doi-asserted-by":"publisher","DOI":"10.1177\/2325967120935810"},{"key":"e_1_2_12_15_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546512453291"},{"key":"e_1_2_12_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-008-0569-z"},{"key":"e_1_2_12_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546516638082"},{"key":"e_1_2_12_18_1","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2474-14-324"},{"key":"e_1_2_12_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.22687"},{"key":"e_1_2_12_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.25743"},{"key":"e_1_2_12_21_1","doi-asserted-by":"publisher","DOI":"10.1177\/2325967118768086"},{"key":"e_1_2_12_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-016-0071-3"},{"key":"e_1_2_12_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jos.2017.09.023"},{"key":"e_1_2_12_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-010-1251-9"},{"key":"e_1_2_12_25_1","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2022.957435"},{"key":"e_1_2_12_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2021.11.025"},{"key":"e_1_2_12_27_1","doi-asserted-by":"publisher","DOI":"10.21037\/qims-23-1355"}],"container-title":["Journal of Experimental Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jeo2.70366","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jeo2.70366","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jeo2.70366","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,19]],"date-time":"2026-05-19T11:32:52Z","timestamp":1779190372000},"score":1,"resource":{"primary":{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/10.1002\/jeo2.70366"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["10.1002\/jeo2.70366"],"URL":"https:\/\/doi.org\/10.1002\/jeo2.70366","archive":["Portico"],"relation":{},"ISSN":["2197-1153","2197-1153"],"issn-type":[{"value":"2197-1153","type":"print"},{"value":"2197-1153","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7]]},"assertion":[{"value":"2025-02-12","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-06-08","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-18","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70366"}}