{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T19:02:56Z","timestamp":1789844576648,"version":"4.0.1"},"reference-count":42,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T00:00:00Z","timestamp":1761868800000},"content-version":"vor","delay-in-days":30,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T00:00:00Z","timestamp":1759276800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["esskajournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J. exp. orthop."],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This finite element study aims to compare the biomechanical performance of three total knee arthroplasty (TKA) alignment strategies\u2014mechanical alignment, kinematic alignment and inverse kinematic alignment\u2014in knees with different degrees of varus deformity. We hypothesise that alignment choice has limited impact in rather neutral alignment but significant biomechanical effects in mild deformity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Two osteoarthritic patients scheduled for TKA, one with almost neutral alignment (1.5\u00b0) and one with mild (10.4\u00b0) varus deformity, were selected. For each patient, mechanical alignment, kinematic alignment and inverse kinematic alignment strategies were virtually applied using a posterior\u2010stabilised fixed\u2010bearing implant. Patient\u2010specific knee joint geometries, including bones and ligaments, were modelled from CT scans. Gait simulations were conducted following ISO standard. Outputs analysed and compared among alignments included contact areas and contact forces, von Mises stress on the tibial insert, tibial anterior\u2010posterior translation and tibial internal\u2010external rotation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>In the almost neutral knee, all three alignments showed comparable kinematics and kinetics. However, in the mildly deformed case, notable differences emerged. Kinematic alignment achieved more balanced medial\u2010lateral contact areas and forces, while inverse kinematic alignment displayed increased internal\u2010external rotation, indicating potential instability from suboptimal ligament balance. Mechanical alignment resulted in higher medial stress, while kinematic alignment redistributed stress more evenly. Inverse kinematic alignment exhibited intermediate behaviour, resembling mechanical alignment in force distribution under mild deformity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Alignment strategy plays a critical role in TKA biomechanics, especially in case of patients with mild varus deformity. While similar outcomes are achievable with almost no deformities, patient\u2010specific morphology heavily influences performance under more complex geometries. These findings support the adoption of a personalised alignment approach tailored to individual anatomical characteristics rather than rigid adherence to a single alignment philosophy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence<\/jats:title>\n                    <jats:p>N\/A.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/jeo2.70482","type":"journal-article","created":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T08:54:26Z","timestamp":1761900866000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Increased varus deformity requires greater personalisation of alignment: A finite element biomechanical study"],"prefix":"10.1002","volume":"12","author":[{"given":"Arcangelo","family":"Russo","sequence":"first","affiliation":[{"name":"Department of Medicine and Surgery Kore University of Enna Enna Italy"},{"name":"Orthopaedic and Traumatologic Unit, Umberto I Hospital Azienda Sanitaria Provinciale di Enna Enna Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-6923-6623","authenticated-orcid":false,"given":"Mattia","family":"Sisella","sequence":"additional","affiliation":[{"name":"BEAMS Department (Bio Electro and Mechanical Systems), \u00c9cole Polytechnique de Bruxelles Universit\u00e9 Libre de Bruxelles Bruxelles Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Carrara","sequence":"additional","affiliation":[{"name":"BEAMS Department (Bio Electro and Mechanical Systems), \u00c9cole Polytechnique de Bruxelles Universit\u00e9 Libre de Bruxelles Bruxelles Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicol","family":"Giacoppo","sequence":"additional","affiliation":[{"name":"BEAMS Department (Bio Electro and Mechanical Systems), \u00c9cole Polytechnique de Bruxelles Universit\u00e9 Libre de Bruxelles Bruxelles Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppe Gianluca","family":"Costa","sequence":"additional","affiliation":[{"name":"Department of Medicine and Surgery Kore University of Enna Enna Italy"},{"name":"Orthopaedic and Traumatologic Unit, Umberto I Hospital Azienda Sanitaria Provinciale di Enna Enna Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gianluca","family":"Zocco","sequence":"additional","affiliation":[{"name":"Department of Medicine and Surgery Kore University of Enna Enna Italy"},{"name":"Orthopaedic and Traumatologic Unit, Umberto I Hospital Azienda Sanitaria Provinciale di Enna Enna Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8992-8865","authenticated-orcid":false,"given":"Bernardo","family":"Innocenti","sequence":"additional","affiliation":[{"name":"BEAMS Department (Bio Electro and Mechanical Systems), \u00c9cole Polytechnique de Bruxelles Universit\u00e9 Libre de Bruxelles Bruxelles Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,10,31]]},"reference":[{"key":"e_1_2_11_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-011-1936-5"},{"key":"e_1_2_11_3_1","doi-asserted-by":"publisher","DOI":"10.1186\/s42836-022-00157-0"},{"key":"e_1_2_11_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-018-5207-9"},{"key":"e_1_2_11_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/ksa.12545"},{"key":"e_1_2_11_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2023.10.003"},{"key":"e_1_2_11_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-016-2571-0"},{"key":"e_1_2_11_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(18)32531-5"},{"key":"e_1_2_11_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-019-05509-z"},{"key":"e_1_2_11_10_1","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20080901-15"},{"key":"e_1_2_11_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-015-2743-5"},{"key":"e_1_2_11_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-019-05764-0"},{"key":"e_1_2_11_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2015.07.038"},{"key":"e_1_2_11_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2014.01.020"},{"key":"e_1_2_11_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jor.2020.10.006"},{"key":"e_1_2_11_16_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.4040966"},{"key":"e_1_2_11_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2016.07.006"},{"key":"e_1_2_11_18_1","doi-asserted-by":"publisher","DOI":"10.1186\/s42836-025-00319-w"},{"key":"e_1_2_11_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2015.02.019"},{"key":"e_1_2_11_20_1","volume-title":"Implants for surgery. Wear of total knee\u2010joint prostheses. loading and displacement parameters for wear\u2010testing machines with displacement control and corresponding environmental conditions for test","author":"ISO","year":"2009"},{"key":"e_1_2_11_21_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0039-1677846"},{"key":"e_1_2_11_22_1","doi-asserted-by":"publisher","DOI":"10.3390\/jpm12081285"},{"key":"e_1_2_11_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-017-4558-y"},{"key":"e_1_2_11_24_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-022-03097-2"},{"key":"e_1_2_11_25_1","doi-asserted-by":"publisher","DOI":"10.1051\/sicotj\/2021021"},{"key":"e_1_2_11_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-022-05571-2"},{"key":"e_1_2_11_27_1","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2023.1120908"},{"key":"e_1_2_11_28_1","doi-asserted-by":"publisher","DOI":"10.1302\/2046-3758.61.BJR-2016-0090.R1"},{"key":"e_1_2_11_29_1","doi-asserted-by":"publisher","DOI":"10.1302\/2058-5241.5.200010"},{"key":"e_1_2_11_30_1","doi-asserted-by":"publisher","DOI":"10.1097\/CORR.0000000000003356"},{"key":"e_1_2_11_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-023-05099-z"},{"key":"e_1_2_11_32_1","doi-asserted-by":"publisher","DOI":"10.11138\/mltj\/2017.7.4.546"},{"key":"e_1_2_11_33_1","unstructured":"PianigianiS InnocentiB.The use of finite element modeling to improve biomechanical research on knee prosthesis. In: New Developments in Knee Prosthesis Research.2015:113\u2013125."},{"key":"e_1_2_11_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.artd.2023.101127"},{"key":"e_1_2_11_35_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.20255"},{"key":"e_1_2_11_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2024.106353"},{"key":"e_1_2_11_37_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.25642"},{"key":"e_1_2_11_38_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0041-1740392"},{"key":"e_1_2_11_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2009.01.001"},{"key":"e_1_2_11_40_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-023-07464-2"},{"key":"e_1_2_11_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2022.103305"},{"key":"e_1_2_11_42_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-020-06165-4"},{"key":"e_1_2_11_43_1","article-title":"Application strategy of finite element analysis in artificial knee arthroplasty","volume":"11","author":"Zhang Z\u2010H","year":"2023","journal-title":"Front Bioeng Biotechnol"}],"container-title":["Journal of Experimental Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jeo2.70482","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jeo2.70482","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jeo2.70482","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T18:24:06Z","timestamp":1789842246000},"score":1,"resource":{"primary":{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/10.1002\/jeo2.70482"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":42,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,10]]}},"alternative-id":["10.1002\/jeo2.70482"],"URL":"https:\/\/doi.org\/10.1002\/jeo2.70482","archive":["Portico"],"relation":{},"ISSN":["2197-1153","2197-1153"],"issn-type":[{"value":"2197-1153","type":"print"},{"value":"2197-1153","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10]]},"assertion":[{"value":"2025-09-02","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-03","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-31","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70482"}}