{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T16:51:21Z","timestamp":1792083081258,"version":"4.4.0"},"reference-count":32,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T00:00:00Z","timestamp":1786320000000},"content-version":"vor","delay-in-days":40,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["esskajournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J. exp. orthop."],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Synthetic grafts for anterior cruciate ligament (ACL) reconstruction aim to address limitations of biological grafts, such as donor\u2010site morbidity and delayed recovery. JewelACL is a synthetic scaffold developed to enhance biological integration and mechanical durability. This multicenter study evaluated long\u2010term patient\u2010reported outcomes, adverse events, re\u2010rupture rates and return\u2010to\u2010sport outcomes following ACL reconstruction using JewelACL, with a minimum follow\u2010up of 9 years.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A retrospective cohort of 58 patients who underwent ACL reconstruction between 2010 and 2014, using either JewelACL alone (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200944) or JewelACL combined with hamstring autograft (hybrid technique;\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200914), was assessed. Patient\u2010reported outcome measures (PROMs), including the International Knee Documentation Committee (IKDC), Lysholm and Tegner scores, as well as complication and re\u2010rupture rates, were analysed. Long\u2010term follow\u2010up was based on telephone\u2010administered PROMs; no standardised clinical laxity testing or imaging (magnetic resonance imaging or x\u2010ray) was performed.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      At a mean follow\u2010up of 10.8\u2009\u00b1\u20090.9 years, the re\u2010rupture rate was (5.2%) 3 cases out of 58. Median Lysholm and IKDC scores were 100 (interquartile range [IQR] 91\u2013100) and 95 (IQR 89\u201399), respectively, indicating excellent long\u2010term knee function. The mean Tegner score at follow\u2010up was 5.2\u2009\u00b1\u20091.7, representing a modest decline from the pre\u2010injury level of 6.5, consistent with age\u2010related reductions in activity. No patient\u2010reported infections or hospital admissions related to the operated knee were reported. IKDC scores were significantly higher in the JewelACL\u2010only group than in the hybrid group (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.02), while Lysholm and Tegner scores did not differ significantly.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      ACL reconstruction using JewelACL was associated with excellent long\u2010term PROMs, low re\u2010rupture rates and high return\u2010to\u2010sport rates. Although these findings are encouraging, interpretation is limited by the retrospective design, substantial loss to follow\u2010up and the absence of imaging or objective clinical assessments. There was no statistically significant difference in return\u2010to\u2010sport rates between the JewelACL group (85%) and the hybrid group (86%) (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20091.00).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence<\/jats:title>\n                    <jats:p>Level IV.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/jeo2.70838","type":"journal-article","created":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T12:01:30Z","timestamp":1786363290000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Patient\u2010reported outcomes after anterior cruciate ligament reconstruction with the JewelACL synthetic ligament: Multicenter study of at least 9 years follow\u2010up"],"prefix":"10.1002","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-4865-3149","authenticated-orcid":false,"given":"Klaudiusz","family":"Kosowski","sequence":"first","affiliation":[{"name":"Med Polonia Private Hospital Poznan Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ewa","family":"Br\u0119borowicz","sequence":"additional","affiliation":[{"name":"Traumatology, Orthopaedics and Hand Surgery Department Institute Poznan University of Medical Sciences Poznan Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marek","family":"Olek","sequence":"additional","affiliation":[{"name":"Med Polonia Private Hospital Poznan Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maciej","family":"Wi\u015bniewski","sequence":"additional","affiliation":[{"name":"Traumatology and Orthopaedics Department District State Hospital K\u0119pno K\u0119pno Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,8,10]]},"reference":[{"key":"e_1_2_12_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2011.04.030"},{"key":"e_1_2_12_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.10.010"},{"key":"e_1_2_12_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2018.01.047"},{"key":"e_1_2_12_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-018-2304-x"},{"key":"e_1_2_12_6_1","first-page":"57","article-title":"LARSTM in ACL reconstruction: evaluation of 60 cases with 5\u2010year minimum follow\u2010up","volume":"102","author":"Bugelli G","year":"2018","journal-title":"Musculoskelet Surg"},{"key":"e_1_2_12_7_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-017-0671-3"},{"key":"e_1_2_12_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546517721692"},{"key":"e_1_2_12_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2024.03.050"},{"key":"e_1_2_12_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-019-05680-3"},{"key":"e_1_2_12_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2013.04.014"},{"key":"e_1_2_12_12_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjsports-2012-091786"},{"key":"e_1_2_12_13_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12144567"},{"key":"e_1_2_12_14_1","doi-asserted-by":"publisher","DOI":"10.1177\/2325967119879079"},{"key":"e_1_2_12_15_1","doi-asserted-by":"publisher","DOI":"10.1177\/03635465030310011501"},{"key":"e_1_2_12_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.01.045"},{"key":"e_1_2_12_17_1","doi-asserted-by":"publisher","DOI":"10.5792\/ksrr.17.065"},{"key":"e_1_2_12_18_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjsports-2019-100765"},{"key":"e_1_2_12_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01577404"},{"key":"e_1_2_12_20_1","doi-asserted-by":"publisher","DOI":"10.2302\/kjm.50.161"},{"key":"e_1_2_12_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/jeo2.70326"},{"key":"e_1_2_12_22_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm14010032"},{"key":"e_1_2_12_23_1","first-page":"6","article-title":"Clinical evaluation report: JewelACL synthetic ligament","volume":"1","author":"Neoligaments Ltd","year":"2021","journal-title":"CRE027"},{"key":"e_1_2_12_24_1","doi-asserted-by":"publisher","DOI":"10.4081\/or.2017.6833"},{"key":"e_1_2_12_25_1","doi-asserted-by":"publisher","DOI":"10.1136\/jisakos-2020-000567"},{"key":"e_1_2_12_26_1","doi-asserted-by":"publisher","DOI":"10.1097\/JSM.0000000000000730"},{"key":"e_1_2_12_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/os.12662"},{"key":"e_1_2_12_28_1","doi-asserted-by":"publisher","DOI":"10.5704\/MOJ.2007.023"},{"key":"e_1_2_12_29_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-018-5280-0"},{"key":"e_1_2_12_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-019-05478-3"},{"key":"e_1_2_12_31_1","doi-asserted-by":"publisher","DOI":"10.1089\/ten.teb.2016.0181"},{"key":"e_1_2_12_32_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12178-019-09588-w"},{"key":"e_1_2_12_33_1","unstructured":"Xiros Ltd. IFU library.https:\/\/xiros.co.uk\/"}],"container-title":["Journal of Experimental Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jeo2.70838","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jeo2.70838","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jeo2.70838","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T16:03:28Z","timestamp":1792080208000},"score":1,"resource":{"primary":{"URL":"https:\/\/esskajournals.onlinelibrary.wiley.com\/doi\/10.1002\/jeo2.70838"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":32,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["10.1002\/jeo2.70838"],"URL":"https:\/\/doi.org\/10.1002\/jeo2.70838","archive":["Portico"],"relation":{},"ISSN":["2197-1153","2197-1153"],"issn-type":[{"value":"2197-1153","type":"print"},{"value":"2197-1153","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"2026-03-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-06","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-10","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70838"}}