{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T23:29:31Z","timestamp":1778542171784,"version":"3.51.4"},"reference-count":40,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2001,11,20]],"date-time":"2001-11-20T00:00:00Z","timestamp":1006214400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2001,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The purpose of this investigation was to evaluate the diagnostic capabilities of magnetic resonance imaging (MRI) performed using a dedicated\u2010extremity MR system in detecting lesions of the rotator cuff and glenoid labrum. This retrospective study compared the MR results obtained in 47 patients that underwent MRI using a 0.2\u2010Tesla extremity MR system (E\u2010scan) to the surgical findings. MR images of the shoulder were obtained as follows: shoulder coil, T1\u2010weighted, coronal\u2010oblique and axial images; short Tau inversion recovery (STIR), coronal\u2010oblique images; and T2\u2010weighted, coronal\u2010oblique, sagittal\u2010oblique, and axial images. The MR examinations were interpreted by three highly experienced, musculoskeletal radiologists. Open surgical (<jats:italic>N<\/jats:italic> = 26) or arthroscopic (<jats:italic>N<\/jats:italic> = 21) procedures were performed within a mean time of 33 days after MRI. The surgical findings revealed rotator cuff tears in 28 patients and labral lesions in 9 patients. For the rotator cuff tears, the sensitivity, specificity, positive predictive value, and negative predictive value were 89%, 100%, 100%, and 90%, respectively. For the labral lesions, the sensitivity, specificity, positive predictive value, and negative predictive value were 89%, 95%, 80%, and 97%, respectively. The findings indicated that there was good agreement comparing the MR results obtained using the low\u2010field extremity MR system to the surgical findings for determination of lesions of the rotator cuff and glenoid labrum. Notably, the statistical values determined for the use of this MR system were comparable to those reported in the peer\u2010reviewed literature for the use of whole\u2010body, mid\u2010 and high\u2010field\u2010strength MR systems. J. Magn. Reson. Imaging 2001;14:763\u2013770. \u00a9 2001 Wiley\u2010Liss, Inc.<\/jats:p>","DOI":"10.1002\/jmri.10014","type":"journal-article","created":{"date-parts":[[2002,8,25]],"date-time":"2002-08-25T16:20:51Z","timestamp":1030292451000},"page":"763-770","source":"Crossref","is-referenced-by-count":53,"title":["Evaluation of the rotator cuff and glenoid labrum using a 0.2\u2010Tesla extremity magnetic resonance (MR) system: MR results compared to surgical findings"],"prefix":"10.1002","volume":"14","author":[{"given":"Frank G.","family":"Shellock","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jack M.","family":"Bert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hollis M.","family":"Fritts","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cooper R.","family":"Gundry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruth","family":"Easton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"III","given":"John V.","family":"Crues","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2001,11,20]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.172.1.2740508"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.177.3.2243995"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.158.2.1729796"},{"key":"e_1_2_6_5_2","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/S1064-9689(21)00287-7","article-title":"Magnetic resonance imaging of impingement and rotator cuff tears","volume":"1","author":"Stoller DW","year":"1993","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.164.6.7754891"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002142-199400620-00004"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880070411"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.174.4.1741107"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.159.4.1529844"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.179.2.2014303"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.163.6.7992740"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.215.3.r00jn26841"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0887-2171(05)80003-4"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1053\/crad.1999.0374"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00182495"},{"key":"e_1_2_6_17_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0033-8389(22)00576-0","article-title":"Dedicated extremity MR imaging: an emerging technology","volume":"35","author":"Peterfy CG","year":"1997","journal-title":"Radiol Clin N Am"},{"key":"e_1_2_6_18_2","first-page":"382","article-title":"Accuracy of imaging the menisci on an in\u2010office, dedicated, magnetic resonance imaging extremity system","volume":"25","author":"Franklin PD","year":"1998","journal-title":"Am J Sports Med"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.206.3.9494494"},{"key":"e_1_2_6_20_2","first-page":"P07H","article-title":"Determination of chondral lesions using a 0.2 Tesla extremity MR system: diagnostic findings compared to arthroscopy","volume":"214","author":"Shellock FG","year":"2000","journal-title":"Radiology"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005768-199906000-00005"},{"key":"e_1_2_6_22_2","first-page":"44","article-title":"Kinematic MRI evaluation of the effect of bracing on patellar positions: qualitative assessment using an extremity MR system","volume":"35","author":"Shellock FG","year":"2000","journal-title":"J Athletic Training"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1007\/s003300050851"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s001170050475"},{"key":"e_1_2_6_25_2","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/S1064-9689(21)00587-0","article-title":"Dedicated extremity MR imaging of the knee: how low can we go?","volume":"8","author":"Hollister MC","year":"2000","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.208.2.9680568"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.172.1.9888762"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199173010-00004"},{"key":"e_1_2_6_29_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.195.2.7724773"},{"key":"e_1_2_6_30_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.194.3.7862988"},{"key":"e_1_2_6_31_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.204.1.9205245"},{"key":"e_1_2_6_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(97)90005-0"},{"key":"e_1_2_6_33_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880060149"},{"key":"e_1_2_6_34_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004424-199807000-00007"},{"key":"e_1_2_6_35_2","first-page":"146","article-title":"MR patterns of rotator cuff and labral lesions: comparison between low\u2010field and high\u2010field images","volume":"92","author":"Shih TT","year":"1994","journal-title":"J Formos Med Assoc"},{"key":"e_1_2_6_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0720-048X(98)00134-X"},{"key":"e_1_2_6_37_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.180.3.1871287"},{"key":"e_1_2_6_38_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004424-199502000-00009"},{"key":"e_1_2_6_39_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-2586(200001)11:1<56::AID-JMRI8>3.0.CO;2-D"},{"key":"e_1_2_6_40_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-1011005"},{"key":"e_1_2_6_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(00)90080-X"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjmri.10014","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.10014","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T19:56:26Z","timestamp":1696881386000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.10014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,11,20]]},"references-count":40,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2001,12]]}},"alternative-id":["10.1002\/jmri.10014"],"URL":"https:\/\/doi.org\/10.1002\/jmri.10014","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,11,20]]}}}