{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,25]],"date-time":"2026-04-25T09:53:40Z","timestamp":1777110820801,"version":"3.51.4"},"reference-count":20,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2005,11,17]],"date-time":"2005-11-17T00:00:00Z","timestamp":1132185600000},"content-version":"vor","delay-in-days":3183,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[1997,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Echo\u2010planar techniques in MRI use a rapidly oscillating frequency\u2010encoding gradient with the potential to produce peripheral nerve stimulation. To evaluate the incidence, type, and location of stimulation in a commercial whole\u2010body scanner, we studied two groups: (a) 173 consecutive individuals scanned by echo\u2010planar imaging for other purposes and (b) seven subjects who were scanned with an extensive set of 36 echo\u2010planar sequences (with prompting after each scan to report any peripheral nerve stimulation) to test the effects of various parameters. Although only 5% of group A reported symptoms of peripheral nerve stimulation, all in group B experienced some type of stimulation, dependent primarily on direction of the oscillating gradient and location of the body within the gradient coil. Maximum stimulation typically occurred 30 to 40 cm from isocenter in the region of maximum dB\/dt. Generally, y gradients produced truncal stimulation, and x gradients produced stimulation in the head. When hands were clasped over the abdomen, a tingling in the hands occasionally was felt. Patients should be instructed to keep their hands apart.<\/jats:p>","DOI":"10.1002\/jmri.1880070226","type":"journal-article","created":{"date-parts":[[2007,3,15]],"date-time":"2007-03-15T14:07:33Z","timestamp":1173967653000},"page":"405-409","source":"Crossref","is-referenced-by-count":28,"title":["Peripheral nerve stimulation in a whole\u2010body echo\u2010planar imaging system"],"prefix":"10.1002","volume":"7","author":[{"given":"James C.","family":"Ehrhardt","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chin\u2010S","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vincent A.","family":"Magnotta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David J.","family":"Fisher","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William T. C.","family":"Yuh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,11,17]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02446217"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1992.tb49633.x"},{"key":"e_1_2_1_4_2","first-page":"314","volume-title":"NMR imaging in biomedicine","author":"Mansfield P","year":"1982"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1992.tb49630.x"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1992.tb49601.x"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-199111000-00001"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910140226"},{"key":"e_1_2_1_9_2","first-page":"1157","volume-title":"Proceedings of the 9th annual meeting of the Society of Magnetic Resonance in Medicine","author":"Bourland JD","year":"1990"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910330506"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910290606"},{"key":"e_1_2_1_12_2","first-page":"102","volume-title":"Proceedings of the 2nd annual meeting of the Society of Magnetic Resonance","author":"Schmitt F","year":"1994"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910320213"},{"key":"e_1_2_1_14_2","first-page":"239","volume-title":"Intraoperative monitoring techniques in neurosurgery","author":"Osenbach RK","year":"1994"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(85)92413-4"},{"key":"e_1_2_1_16_2","first-page":"1219","volume-title":"Proceedings of the 3rd annual meeting of the Society of Magnetic Resonance","author":"Erhard P","year":"1995"},{"key":"e_1_2_1_17_2","first-page":"101","volume-title":"Proceedings of the 2nd annual meeting of the Society of Magnetic Resonance","author":"Schaefer DJ","year":"1994"},{"key":"e_1_2_1_18_2","first-page":"1221","volume-title":"Proceedings of the 3rd annual meeting of the Society of Magnetic Resonance","author":"Eberhardt KEW","year":"1995"},{"key":"e_1_2_1_19_2","first-page":"1220","volume-title":"Proceedings of the 3rd annual meeting of the Society of Magnetic Resonance","author":"Schaefer DJ","year":"1995"},{"key":"e_1_2_1_20_2","first-page":"309","volume-title":"Proceedings of the 3rd annual meeting of the Society of Magnetic Resonance","author":"Wang W","year":"1995"},{"key":"e_1_2_1_21_2","first-page":"1768","volume-title":"Proceedings of the 4th annual meeting of the International Society for Magnetic Resonance in Medicine","author":"Carbunaru R","year":"1996"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjmri.1880070226","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.1880070226","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,28]],"date-time":"2023-10-28T10:13:51Z","timestamp":1698488031000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.1880070226"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1997,3]]},"references-count":20,"journal-issue":{"issue":"2","published-print":{"date-parts":[[1997,3]]}},"alternative-id":["10.1002\/jmri.1880070226"],"URL":"https:\/\/doi.org\/10.1002\/jmri.1880070226","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[1997,3]]}}}