{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T20:51:47Z","timestamp":1769633507369,"version":"3.49.0"},"reference-count":23,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2011,7,19]],"date-time":"2011-07-19T00:00:00Z","timestamp":1311033600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2011,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose:<\/jats:title><jats:p>To demonstrate the utility of a \u201creduced field\u2010of\u2010view\u201d (zoom imaging) technique to accelerate free\u2010breathing, ECG\u2010triggered, turbo\u2010spin\u2010echo black\u2010blood sequences, which have been previously described to detect subclinical aortic atherosclerosis.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods:<\/jats:title><jats:p>Fifteen healthy volunteers underwent MRI of the thoracic and abdominal aorta. Imaging with the conventional full field\u2010of\u2010view sequence was compared with zoom imaging. Total scan time, image quality (i.e., contrast\u2010to\u2010noise ratio and vessel wall sharpness) and vessel wall thickness were analyzed. A subgroup of 10 volunteers also underwent acceleration of imaging using sensitivity encoding (SENSE) for comparison.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results:<\/jats:title><jats:p>Zoom imaging significantly reduced imaging time from a mean of 41 \u00b1 9 min (conventional imaging) to 15 \u00b1 0.5 min (<jats:italic>P<\/jats:italic> &lt; 0.01). There was no difference in image quality between conventional and zoom imaging with respect to CNR (10.1 \u00b1 6 versus 10.1 \u00b1 6) or vessel wall sharpness (38 \u00b1 4% versus 39 \u00b1 4%). Furthermore, Bland Altman plots showed excellent agreement in vessel wall thickness measurements using the two methods. In comparison, SENSE not only reduced CNR but also resulted in underestimation of vessel wall thickness compared with the conventional sequence.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion:<\/jats:title><jats:p>Zoom imaging allows accurate and time\u2010efficient imaging of the abdominal and thoracic aorta for cardiovascular risk prediction. In this application, it is preferable to SENSE. J. Magn. Reson. Imaging 2011;. \u00a9 2011 Wiley\u2010Liss, Inc.<\/jats:p><\/jats:sec>","DOI":"10.1002\/jmri.22617","type":"journal-article","created":{"date-parts":[[2011,7,20]],"date-time":"2011-07-20T12:02:30Z","timestamp":1311163350000},"page":"279-285","source":"Crossref","is-referenced-by-count":14,"title":["Zoom imaging for rapid aortic vessel wall imaging and cardiovascular risk assessment"],"prefix":"10.1002","volume":"34","author":[{"given":"Tarique","family":"Hussain","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rachel E.","family":"Clough","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marina","family":"Cecelja","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcus","family":"Makowski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sarah","family":"Peel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip","family":"Chowienczyk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tobias","family":"Schaeffter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerald","family":"Greil","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rene","family":"Botnar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,7,19]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2458-8-148"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.109.192666"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2009.09.066"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.ATV.3.3.187"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(93)90729-K"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(96)00670-4"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.101.21.2503"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.ATV.0000012662.29622.00"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1161\/ATVBAHA.107.153544"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880080426"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.10253"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1109\/34.41386"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.99.24.3139"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.20969"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2004.03.008"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.10291"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1268"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000025629.85631.1E"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1177\/0003319710362976"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(90)90282-T"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(97)00701-7"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.105.600866"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1161\/HYPERTENSIONAHA.109.137653"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjmri.22617","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.22617","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T21:01:45Z","timestamp":1697490105000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.22617"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,7,19]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2011,8]]}},"alternative-id":["10.1002\/jmri.22617"],"URL":"https:\/\/doi.org\/10.1002\/jmri.22617","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,7,19]]}}}