{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T13:58:53Z","timestamp":1766066333147},"reference-count":31,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2013,11,7]],"date-time":"2013-11-07T00:00:00Z","timestamp":1383782400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2014,10]]},"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>To perform a prospective quantitative analysis of median nerve T2 values and cross\u2010sectional area (CSA) in patients with carpal tunnel syndrome (CTS) as compared to asymptomatic volunteers.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods<\/jats:title><jats:p>Twelve CTS patients with positive nerve conduction results and 12 healthy volunteers (controls) were enrolled and underwent axial T2 mapping of the wrist joints. Median nerve T2 values and CSAs at the distal radioulnar joint, pisiform, and hook of hamate levels were compared between the groups.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The T2 values at the proximal and distal carpal tunnel were higher in the CTS patients than in the controls (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05). The T2 values at the distal radioulnar joint did not differ between the groups (<jats:italic>P<\/jats:italic>\u2009=\u20090.99). The CSAs of the median nerve at all levels of the carpal tunnel were significantly larger in the CTS patients than in the controls (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>In conclusion, our study demonstrated that median nerve T2 assessment is feasible and that T2 assessment may offer functional information about the median nerve in the carpal tunnel and has the potential to be a promising complementary method for evaluation of CTS patients. A future study with larger sample sizes is necessary to investigate the potential effect of median nerve T2 assessment to a reliable tool in the diagnosis of CTS.<jats:bold>J. Magn. Reson. Imaging 2014;40:789\u2013795<\/jats:bold> \u00a9 <jats:bold>2013 Wiley Periodicals, Inc.<\/jats:bold><\/jats:p><\/jats:sec>","DOI":"10.1002\/jmri.24448","type":"journal-article","created":{"date-parts":[[2013,11,7]],"date-time":"2013-11-07T16:11:07Z","timestamp":1383840667000},"page":"789-795","source":"Crossref","is-referenced-by-count":25,"title":["Median nerve T2 assessment in the wrist joints: Preliminary study in patients with carpal tunnel syndrome and healthy volunteers"],"prefix":"10.1002","volume":"40","author":[{"given":"Jang Gyu","family":"Cha","sequence":"first","affiliation":[{"name":"Department of Radiology Soonchunhyang University Bucheon Hospital Bucheon Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jong Kyu","family":"Han","sequence":"additional","affiliation":[{"name":"Department of Radiology Soonchunhyang University Cheonan Hospital Chungcheongnam\u2010do Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Soo Bin","family":"Im","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery Soonchunhyang University Bucheon Hospital Bucheon Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung Jin","family":"Kang","sequence":"additional","affiliation":[{"name":"Department of Radiology Soonchunhyang University Bucheon Hospital Bucheon Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2013,11,7]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1148\/rg.265055712"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1148\/rg.305095169"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-001-1256-3"},{"key":"e_1_2_5_5_1","first-page":"509","article-title":"Role of magnetic resonance imaging in entrapment and compressive neuropathy\u2010\u2010what, where, and how to see the peripheral nerves on the musculoskeletal magnetic resonance image: part 2","volume":"17","author":"Kim S","year":"2007","journal-title":"Upper extremity. Eur Radiol"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.nic.2004.02.002"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mric.2004.02.008"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006123-199707000-00016"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0720-048X(97)00038-7"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01411366"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.169.6.9393185"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.58.11.1583"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.09091223"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.12111403"},{"key":"e_1_2_5_15_1","first-page":"68","volume-title":"Manual of nerve conduction velocity and neurophysiology","author":"Delisa JA","year":"1994"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/art.23317"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/9780470316672.app1"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.11102357"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2002"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.10.6012"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2521081614"},{"key":"e_1_2_5_22_1","first-page":"361","article-title":"Clinical application of magnetic resonance neurography in peripheral nerve disorders","volume":"22","author":"Zhang H","year":"2006","journal-title":"Neurosci Bull"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.11111060"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0033-8389(05)70132-9"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2005.05.013"},{"key":"e_1_2_5_26_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2321030071"},{"key":"e_1_2_5_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/art.20723"},{"key":"e_1_2_5_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.crad.2004.03.020"},{"key":"e_1_2_5_29_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2501080397"},{"key":"e_1_2_5_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-008-0626-1"},{"key":"e_1_2_5_31_1","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1996.85.2.0299"},{"key":"e_1_2_5_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2007.05.004"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjmri.24448","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.24448","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T12:56:54Z","timestamp":1696337814000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.24448"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,11,7]]},"references-count":31,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2014,10]]}},"alternative-id":["10.1002\/jmri.24448"],"URL":"https:\/\/doi.org\/10.1002\/jmri.24448","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,11,7]]}}}