{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T04:31:42Z","timestamp":1770438702272,"version":"3.49.0"},"reference-count":27,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2014,9,19]],"date-time":"2014-09-19T00:00:00Z","timestamp":1411084800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2015,6]]},"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>To determine the subjective experience of subjects undergoing 7T magnetic resonance imaging (MRI) compared to a mock scanner with no magnetic field.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods and Materials<\/jats:title><jats:p>In all, 44 healthy subjects were exposed to both the <jats:italic>B<\/jats:italic><jats:sub>0<\/jats:sub> field of a 7T whole\u2010body MRI and a realistic mock scanner with no magnetic field. Subjects were blinded to the actual field strength and no scanning was performed. After exposure, subjects rated their experience of potential sensory perceptions.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The most frequently observed side effect was vertigo while entering the gantry, which was reported by 38.6% (<jats:italic>n<\/jats:italic>\u2009=\u200917). Other frequent side effects were the appearance of phosphenes (18.2%, <jats:italic>n<\/jats:italic>\u2009=\u20098), thermal heat sensation (15.9%), unsteady gait after exposure (13.6%, <jats:italic>n<\/jats:italic>\u2009=\u20096), and dizziness (13.6%). All side effects were reported significantly more often after 7T exposure. Nine subjects (20.5%) did not report any sensory perceptions at all, ie, neither in the 7T scanner nor in the mock scanner.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Light, acute, and transient sensory perceptions can occur in subjects undergoing ultrahighfield MRI, of which vertigo seems to be the most frequently reported. Possible psychological effects might contribute to the emergence of such sensory perceptions, as some subjects also reported them to appear in a realistic mock scanner with no magnetic field. <jats:bold>J. Magn. Reson. Imaging 2015;41:1675\u20131681.<\/jats:bold> \u00a9 <jats:bold>2014 Wiley Periodicals, Inc.<\/jats:bold><\/jats:p><\/jats:sec>","DOI":"10.1002\/jmri.24748","type":"journal-article","created":{"date-parts":[[2014,9,19]],"date-time":"2014-09-19T06:23:22Z","timestamp":1411107802000},"page":"1675-1681","source":"Crossref","is-referenced-by-count":21,"title":["Sensory perceptions of individuals exposed to the static field of a 7T MRI: A controlled blinded study"],"prefix":"10.1002","volume":"41","author":[{"given":"Bj\u00f6rn","family":"Friebe","sequence":"first","affiliation":[{"name":"Department of Radiology and Nuclear Medicine Otto\u2010von\u2010Guericke University Magdeburg  Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Astrid","family":"Wollrab","sequence":"additional","affiliation":[{"name":"Department of Biomedical Magnetic Resonance (BMMR), Division Experimental Physics, Faculty of Physics Otto\u2010von\u2010Guericke University Magdeburg  Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Markus","family":"Thormann","sequence":"additional","affiliation":[{"name":"Department of Radiology and Nuclear Medicine Otto\u2010von\u2010Guericke University Magdeburg  Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katharina","family":"Fischbach","sequence":"additional","affiliation":[{"name":"Department of Radiology and Nuclear Medicine Otto\u2010von\u2010Guericke University Magdeburg  Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jens","family":"Ricke","sequence":"additional","affiliation":[{"name":"Department of Radiology and Nuclear Medicine Otto\u2010von\u2010Guericke University Magdeburg  Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcus","family":"Grueschow","sequence":"additional","affiliation":[{"name":"Department of Economics University of Zurich  Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siegfried","family":"Kropf","sequence":"additional","affiliation":[{"name":"Institute for Biometrics and Biomedical Informatics, Otto\u2010von\u2010Guericke University Magdeburg  Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank","family":"Fischbach","sequence":"additional","affiliation":[{"name":"Department of Radiology and Nuclear Medicine Otto\u2010von\u2010Guericke University Magdeburg  Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver","family":"Speck","sequence":"additional","affiliation":[{"name":"Department of Biomedical Magnetic Resonance (BMMR), Division Experimental Physics, Faculty of Physics Otto\u2010von\u2010Guericke University Magdeburg  Germany"},{"name":"Leibniz Institute for Neurobiology Magdeburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2014,9,19]]},"reference":[{"key":"e_1_2_5_2_1","volume-title":"OECD Health Data","author":"OECD","year":"2013"},{"key":"e_1_2_5_3_1","first-page":"437","volume-title":"Ultra high field magnetic resonance imaging","author":"Novak V","year":"2006"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-012-2508-0"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0b013e3181b4c055"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.10604"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.20510"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0730-725X(99)00086-7"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.10367"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.21150"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.12112172"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1992.tb49617.x"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.596827"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.20485"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.10366"},{"key":"e_1_2_5_16_1","unstructured":"MattssonMO AA BridgesJNorppaH SchutzJ.European Parliament and the Council. Research needs and methodology to address the remaining knowledge gaps on the potential health effects of EMF.2013."},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.HP.0000343164.27920.4a"},{"key":"e_1_2_5_18_1","unstructured":"WHO. Environmental Health Criteria 232 static fields.2006."},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/1522-2586(200007)12:1<2::AID-JMRI2>3.0.CO;2-V"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10334-007-0095-x"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20680"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pbiomolbio.2004.08.012"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/bem.20316"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pbiomolbio.2004.08.002"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2011.08.001"},{"key":"e_1_2_5_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.21153"},{"key":"e_1_2_5_27_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016487209128458"},{"key":"e_1_2_5_28_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016488709134691"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjmri.24748","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.24748","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,4]],"date-time":"2023-10-04T23:41:15Z","timestamp":1696462875000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.24748"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,9,19]]},"references-count":27,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2015,6]]}},"alternative-id":["10.1002\/jmri.24748"],"URL":"https:\/\/doi.org\/10.1002\/jmri.24748","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,9,19]]}}}