{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T18:41:29Z","timestamp":1790102489952,"version":"4.0.1"},"reference-count":74,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2015,2,24]],"date-time":"2015-02-24T00:00:00Z","timestamp":1424736000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2015,10]]},"abstract":"<jats:p>With improvements in surgical and medical management, patients with congenital heart disease (CHD) are often living well into adulthood. MRI provides critical data for diagnosis and monitoring of these patients, yielding information on cardiac anatomy, blood flow, and cardiac function. Though historically these exams have been complex and lengthy, four\u2010dimensional (4D) flow is emerging as a single fast technique for comprehensive assessment of CHD. The 4D flow consists of a volumetric time\u2010resolved acquisition that is gated to the cardiac cycle, providing a time\u2010varying vector field of blood flow as well as registered anatomic images. In this article, we provide an overview of MRI evaluation of congenital heart disease by means of example of three relatively common representative conditions: tetralogy of Fallot, aortic coarctation, and anomalous pulmonary venous drainage. Then 4D flow data acquisition, data correction, and postprocessing techniques are reviewed. We conclude with several examples that highlight the comprehensive nature of the evaluation of congenital heart disease with 4D flow. J. Magn. Reson. Imaging 2015;42:870\u2013886.<\/jats:p>","DOI":"10.1002\/jmri.24856","type":"journal-article","created":{"date-parts":[[2015,2,24]],"date-time":"2015-02-24T01:00:51Z","timestamp":1424739651000},"page":"870-886","source":"Crossref","is-referenced-by-count":122,"title":["Congenital heart disease assessment with 4D flow MRI"],"prefix":"10.1002","volume":"42","author":[{"given":"Shreyas S.","family":"Vasanawala","sequence":"first","affiliation":[{"name":"Department of Radiology Stanford University Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kate","family":"Hanneman","sequence":"additional","affiliation":[{"name":"Department of Radiology University of California, San Diego San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus T.","family":"Alley","sequence":"additional","affiliation":[{"name":"Department of Radiology Stanford University Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Albert","family":"Hsiao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2015,2,24]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(02)01886-7"},{"key":"e_1_2_9_3_1","first-page":"4","article-title":"The segmental approach to diagnosis in congenital heart disease","volume":"8","author":"Praagh R","year":"1972","journal-title":"Birth Defects"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.cir.0000442015.53336.12"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2009.08.014"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2010.03.110"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.4103\/0974-2069.43873"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1186\/1532-429X-13-9"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2003.10.045"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2005.03.058"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(02)02566-4"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.5603\/CJ.2011.0003"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2013.06.016"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.80.4.840"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(01)01572-8"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1136\/heart.88.2.113"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.57.5.462"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.05.0424"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.22083"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.10036"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.182.5.1821139"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2010.12.069"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.113.005004"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.108.190811"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0828-282X(10)70354-8"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00348-007-0383-2"},{"key":"e_1_2_9_27_1","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/S1064-9689(21)00253-1","article-title":"Flow quantification and analysis methods","volume":"3","author":"Pelc NJ","year":"1995","journal-title":"Magn Reson Imaging Clin North Am"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880010404"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910090117"},{"key":"e_1_2_9_30_1","first-page":"229","article-title":"Phase contrast cine magnetic resonance imaging","volume":"7","author":"Pelc NJ","year":"1991","journal-title":"Magn Reson Q"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2321030783"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880010404"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910150308"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910330119"},{"key":"e_1_2_9_35_1","first-page":"299","volume-title":"Magnetic resonance annual 1988","author":"Glover GH","year":"1988"},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910360521"},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.1002\/1522-2586(200008)12:2<321::AID-JMRI15>3.0.CO;2-2"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.10272"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-198507010-00039"},{"key":"e_1_2_9_40_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.173.1.2781017"},{"key":"e_1_2_9_41_1","doi-asserted-by":"publisher","DOI":"10.1081\/JCMR-100107467"},{"key":"e_1_2_9_42_1","doi-asserted-by":"publisher","DOI":"10.1081\/JCMR-200036119"},{"key":"e_1_2_9_43_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.20871"},{"key":"e_1_2_9_44_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24874"},{"key":"e_1_2_9_45_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22090"},{"key":"e_1_2_9_46_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21109"},{"key":"e_1_2_9_47_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21391"},{"key":"e_1_2_9_48_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.11.6969"},{"key":"e_1_2_9_49_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.10091218"},{"key":"e_1_2_9_50_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20730"},{"key":"e_1_2_9_51_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22875"},{"key":"e_1_2_9_52_1","first-page":"743","article-title":"PC VIPR: a high\u2010speed 3D phase\u2010contrast method for flow quantification and high\u2010resolution angiography","volume":"26","author":"Gu T","year":"2005","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_2_9_53_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.23297"},{"key":"e_1_2_9_54_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.22712"},{"key":"e_1_2_9_55_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.109.931857"},{"key":"e_1_2_9_56_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.23936"},{"key":"e_1_2_9_57_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.10582"},{"key":"e_1_2_9_58_1","unstructured":"GloverGH PelcNJ.Method for correcting image distortion due to gradient nonuniformity. US Patent Office; U.S. patent number 4591789 1986."},{"key":"e_1_2_9_59_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910390218"},{"key":"e_1_2_9_60_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910170119"},{"key":"e_1_2_9_61_1","unstructured":"GloverGH PelcNJ BradshawKM.Gradient and polarizing field compensation. US Patent Office; U.S. patent number 4950994 1990."},{"key":"e_1_2_9_62_1","doi-asserted-by":"crossref","unstructured":"GloverGH PelcNJ.Method for magnetic field gradient eddy current compensation. US Patent Office; U.S. patent number 4698591 1987.","DOI":"10.1016\/0730-725X(88)90464-X"},{"key":"e_1_2_9_63_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880030315"},{"key":"e_1_2_9_64_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-010-1932-z"},{"key":"e_1_2_9_65_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2492080146"},{"key":"e_1_2_9_66_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0b013e3181ae99b5"},{"key":"e_1_2_9_67_1","article-title":"Inlet and outlet valve flow and regurgitant volume may be directly and reliably quantified with accelerated, volumetric phase\u2010contrast MRI","author":"Hsiao A","year":"2014","journal-title":"J Magn Reson Imaging"},{"key":"e_1_2_9_68_1","doi-asserted-by":"publisher","DOI":"10.1186\/1532-429X-16-23"},{"key":"e_1_2_9_69_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.12120055"},{"key":"e_1_2_9_70_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.10092269"},{"key":"e_1_2_9_71_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-011-2108-4"},{"key":"e_1_2_9_72_1","doi-asserted-by":"publisher","DOI":"10.1186\/1532-429X-14-16"},{"key":"e_1_2_9_73_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.22861"},{"key":"e_1_2_9_74_1","doi-asserted-by":"publisher","DOI":"10.1186\/1532-429X-14-25"},{"key":"e_1_2_9_75_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2014.04.012"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjmri.24856","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.24856","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T08:26:46Z","timestamp":1696494406000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.24856"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2,24]]},"references-count":74,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2015,10]]}},"alternative-id":["10.1002\/jmri.24856"],"URL":"https:\/\/doi.org\/10.1002\/jmri.24856","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2,24]]}}}