{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:54:33Z","timestamp":1787068473034,"version":"build-2736575974"},"reference-count":46,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2017,5,4]],"date-time":"2017-05-04T00:00:00Z","timestamp":1493856000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2017,9]]},"abstract":"<jats:sec>\n                    <jats:label\/>\n                    <jats:p>Magnetic resonance imaging (MRI)\u2010guided interventions, including biopsies and wire localizations, are fundamental to any breast imaging practice due to the high sensitivity but limited specificity of breast MRI. The basic steps of MRI\u2010guided biopsies are similar regardless of the vendor or platform, and technical considerations include approach planning, patient preparation and positioning, lesion targeting, and directional sampling using a vacuum\u2010assisted biopsy technique. Unique challenges related to MRI\u2010guided biopsies include vanishing lesions due to contrast washout, obscuration of the biopsy site due to susceptibility artifacts, and limited access to posteromedial lesions. A careful approach to planning, patient positioning, and lesion targeting will maximize the chances for a successful biopsy. Due to overlapping imaging features between benign and malignant lesions, radiologic\u2010pathologic concordance is difficult and essential for further patient management.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>Level of Evidence<\/jats:bold>\n                      : 5\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>Technical Efficacy:<\/jats:bold>\n                      Stage 3\n                    <\/jats:p>\n                    <jats:p>J. MAGN. RESON. IMAGING 2017;46:631\u2013645<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/jmri.25738","type":"journal-article","created":{"date-parts":[[2017,5,4]],"date-time":"2017-05-04T02:18:48Z","timestamp":1493864328000},"page":"631-645","source":"Crossref","is-referenced-by-count":32,"title":["MRI\u2010guided breast interventions"],"prefix":"10.1002","volume":"46","author":[{"given":"Anika L.","family":"McGrath","sequence":"first","affiliation":[{"name":"Department of Radiology University of Washington School of Medicine Seattle Washington USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elissa R.","family":"Price","sequence":"additional","affiliation":[{"name":"Department of Radiology and Biomedical Imaging University of California San Francisco California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter R.","family":"Eby","sequence":"additional","affiliation":[{"name":"Department of Radiology Virginia Mason Medical Center Seattle Washington USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Habib","family":"Rahbar","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Washington School of Medicine Seattle Washington USA"},{"name":"Breast Imaging Seattle Cancer Care Alliance Seattle Washington USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,5,4]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2461061298"},{"key":"e_1_2_10_3_1","unstructured":"American College of Radiology (ACR).Breast Magnetic Imaging (MRI) Accreditation Program Requirements. May 9 2016. Accessed October 4 2016. Available from:http:\/\/www.acraccreditation.org\/\u223c\/media\/ACRAccreditation\/Documents\/Breast\u2010MRI\/Requirements.pdf?la=en"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacr.2009.09.022"},{"key":"e_1_2_10_5_1","unstructured":"American College of Radiology (ACR).ACR Practice Parameter for the Performance of Magnetic Resonance Imaging\u2010Guided Breast Interventional Procedures. Revised2016. Accessed October 4 2016. Available from:http:\/\/www.acr.org\/\u223c\/media\/FFD2D1CA57ED479DBB6DD0DA0D9E3A87.pdf"},{"key":"e_1_2_10_6_1","volume-title":"ACR BI\u2010RADS\u00ae Atlas, Breast Imaging Reporting and Data System","author":"Morris EA","year":"2013"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1201\/b19675-15"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.292.22.2735"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.3987"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.14140474"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.09.2707"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.tvir.2013.12.007"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.09.2480"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.3537"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.09.2366"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mric.2013.03.002"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2013.11.004"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.3736"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.13.10600"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/cncr.21720"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.2531"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.08.2226"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.11.7455"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinimag.2016.06.005"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.crad.2014.02.003"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.185.1.01850183"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.06.0809"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.09.4081"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.11.7610"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-010-1949-6"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-013-2989-5"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.2172"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-002-1713-7"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2013.01.005"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.12.10228"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2013.52.5386"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2014.10.004"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000057"},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.16.17205"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.2463\/mrms.6.21"},{"key":"e_1_2_10_41_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.15.15873"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-010-1890-8"},{"key":"e_1_2_10_43_1","first-page":"1","article-title":"MRI\u2010guided breast vacuum biopsy: localization of the lesion without contrast agent application using diffusion\u2010weighted imaging","volume":"28","author":"Berger N","year":"2016","journal-title":"Magn Reson Imaging"},{"key":"e_1_2_10_44_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2014.03.006"},{"key":"e_1_2_10_45_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.16.16808"},{"key":"e_1_2_10_46_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.2827"},{"key":"e_1_2_10_47_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-016-4267-9"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjmri.25738","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.25738","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,4]],"date-time":"2023-10-04T21:27:28Z","timestamp":1696454848000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.25738"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5,4]]},"references-count":46,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,9]]}},"alternative-id":["10.1002\/jmri.25738"],"URL":"https:\/\/doi.org\/10.1002\/jmri.25738","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,5,4]]}}}