{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T19:08:52Z","timestamp":1790708932362,"version":"4.1.0"},"reference-count":40,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2018,4,11]],"date-time":"2018-04-11T00:00:00Z","timestamp":1523404800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2018,10]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>In patients with mitral or tricuspid valve regurgitation, evaluation of regurgitant severity is essential for determining the need for surgery. While transthoracic echocardiography is widely accessible, it has limited reproducibility for grading inlet valve regurgitation. Multiplanar cardiac MRI is the quantitative standard but requires specialized local expertise, and is thus not widely available. Volumetric 4D flow MRI has potential for quantitatively grading the severity of inlet valve regurgitation in adult patients.<\/jats:p><\/jats:sec><jats:sec><jats:title>Purpose<\/jats:title><jats:p>To evaluate the accuracy and reproducibility of volumetric 4D flow MRI for quantification of inlet valvular regurgitation compared to conventional multiplanar MRI, which may simplify and improve accessibility of cardiac MRI.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study Type<\/jats:title><jats:p>This retrospective, HIPAA\u2010compliant imaging\u2010based comparison study was conducted at a single institution.<\/jats:p><\/jats:sec><jats:sec><jats:title>Subjects<\/jats:title><jats:p>Twenty\u2010one patients who underwent concurrent multiplanar and 4D flow cardiac MRI between April 2015 and January 2017.<\/jats:p><\/jats:sec><jats:sec><jats:title>Field Strength\/Sequences<\/jats:title><jats:p>3T; steady\u2010state free\u2010precession (SSFP), 2D phase contrast (2D\u2010PC), and postcontrast 4D flow.<\/jats:p><\/jats:sec><jats:sec><jats:title>Assessment<\/jats:title><jats:p>We evaluated the intertechnique (4D flow vs. 2D\u2010PC), intermethod (<jats:italic>direct<\/jats:italic> vs. <jats:italic>indirect<\/jats:italic> measurement), interobserver and intraobserver reproducibility of measurements of regurgitant flow volume (RFV), fraction (RF), and volume (RVol).<\/jats:p><\/jats:sec><jats:sec><jats:title>Statistical Tests<\/jats:title><jats:p>Statistical analysis included Pearson correlation, Bland\u2013Altman statistics, and intraclass correlation coefficients.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>There was high concordance between 4D flow and multiplanar MRI, whether using direct or indirect methods of quantifying regurgitation (<jats:italic>r<\/jats:italic>\u2009=\u20090.813\u20130.985). Direct interrogation of the regurgitant jet with 4D flow showed high intraobserver consistency (<jats:italic>r<\/jats:italic>\u2009=\u20090.976\u20130.999) and interobserver consistency (<jats:italic>r<\/jats:italic>\u2009=\u20090.861\u20130.992), and correlated well with traditional indirect measurements obtained as the difference between stroke volume and forward outlet valve flow.<\/jats:p><\/jats:sec><jats:sec><jats:title>Data Conclusion<\/jats:title><jats:p>4D flow MRI provides highly reproducible measurements of mitral and tricuspid regurgitant volume, and may be used in place of conventional multiplanar MRI.<\/jats:p><jats:p><jats:bold>Level of Evidence<\/jats:bold>: 4<\/jats:p><jats:p><jats:bold>Technical Efficacy<\/jats:bold>: Stage 2<\/jats:p><jats:p>J. Magn. Reson. Imaging 2018;48:1147\u20131158.<\/jats:p><\/jats:sec>","DOI":"10.1002\/jmri.26040","type":"journal-article","created":{"date-parts":[[2018,4,11]],"date-time":"2018-04-11T11:49:20Z","timestamp":1523447360000},"page":"1147-1158","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":100,"title":["4D flow MRI quantification of mitral and tricuspid regurgitation: Reproducibility and consistency relative to conventional MRI"],"prefix":"10.1002","volume":"48","author":[{"given":"Jennifer F.","family":"Feneis","sequence":"first","affiliation":[{"name":"Department of Radiology UC San Diego La Jolla California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Espoir","family":"Kyubwa","sequence":"additional","affiliation":[{"name":"Department of Radiology UC San Diego La Jolla California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kimberly","family":"Atianzar","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Disease Swedish Heart and Vascular Institute Seattle WA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph Y.","family":"Cheng","sequence":"additional","affiliation":[{"name":"Department of Radiology Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus T.","family":"Alley","sequence":"additional","affiliation":[{"name":"Department of Radiology Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shreyas S.","family":"Vasanawala","sequence":"additional","affiliation":[{"name":"Department of Radiology Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony N.","family":"Demaria","sequence":"additional","affiliation":[{"name":"Division of Cardiology UC San Diego La Jolla California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9412-1369","authenticated-orcid":false,"given":"Albert","family":"Hsiao","sequence":"additional","affiliation":[{"name":"Department of Radiology UC San Diego La Jolla California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,4,11]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(09)60692-9"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8191.2011.01274.x"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199611073351902"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.108.802314"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0000000000000503"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2014.02.537"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1530\/ERP-16-0019"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2003.09.036"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(16)00740-6"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2017.01.007"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(94)00434-R"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2009.09.029"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCIMAGING.112.975623"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2016.12.017"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2014.12.047"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1136\/heartjnl-2015-309054"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12968-015-0170-9"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1080\/10976640701545073"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910260115"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.23632"},{"key":"e_1_2_6_22_1","first-page":"229","article-title":"Phase contrast cine magnetic resonance imaging","volume":"7","author":"Pelc NJ","year":"1991","journal-title":"Magn Reson Q"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20145"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.10091218"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.21200"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.10611"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.12120055"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.11.6969"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1177\/0218492317694248"},{"key":"e_1_2_6_30_1","first-page":"1","article-title":"Congenital heart disease assessment with 4D flow MRI","author":"Vasanawala SS","year":"2015","journal-title":"J Magn Reson Imaging"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-010-1932-z"},{"key":"e_1_2_6_32_1","first-page":"1355","article-title":"Comprehensive motion\u2010compensated highly accelerated 4D flow MRI with ferumoxytol enhancement for pediatric congenital heart disease","author":"Cheng JY","year":"2015","journal-title":"J Magn Reson Imaging"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.24785"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24440"},{"key":"e_1_2_6_35_1","first-page":"990","article-title":"ESPIRiT\u2014an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA","volume":"1001","author":"Uecker M","year":"2013","journal-title":"Magn Reson Med"},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.1037\/1082-989X.1.1.30"},{"key":"e_1_2_6_37_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.115.017888"},{"key":"e_1_2_6_38_1","doi-asserted-by":"publisher","DOI":"10.1080\/10976640600604856"},{"key":"e_1_2_6_39_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.596645"},{"key":"e_1_2_6_40_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.167.2.3357951"},{"key":"e_1_2_6_41_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-010-1932-z"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjmri.26040","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.26040","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,16]],"date-time":"2023-09-16T21:53:21Z","timestamp":1694901201000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.26040"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4,11]]},"references-count":40,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2018,10]]}},"alternative-id":["10.1002\/jmri.26040"],"URL":"https:\/\/doi.org\/10.1002\/jmri.26040","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,4,11]]},"assertion":[{"value":"2018-01-04","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-03-20","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-04-11","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}