{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,8]],"date-time":"2026-02-08T19:42:49Z","timestamp":1770579769313,"version":"3.49.0"},"reference-count":27,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2020,8,17]],"date-time":"2020-08-17T00:00:00Z","timestamp":1597622400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2021,5]]},"abstract":"<jats:sec><jats:label\/><jats:p>Historically, the presence of cardiac implantable electronic devices (CIEDs), including pacemakers and implantable cardioverter defibrillators (ICDs), was widely considered an absolute contraindication to magnetic resonance imaging (MRI). The recent development of CIEDs with MR Conditional labeling, as well as encouraging results from retrospective studies and a prospective trial on the safety of MRI performed in patients with CIEDs without MR Conditional labeling, have led to a reevaluation of this practice. The purpose of this report is to provide a concise summary of recent developments, including practical guidelines that an institution could adopt for radiologists who choose to image patients with CIEDs that do not have MR Conditional labeling. This report was written on behalf of and approved by the International Society for Magnetic Resonance in Medicine (ISMRM) Safety Committee.<\/jats:p><\/jats:sec><jats:sec><jats:title>Level of Evidence<\/jats:title><jats:p>3.<\/jats:p><\/jats:sec><jats:sec><jats:title>Technical Efficacy Stage<\/jats:title><jats:p>1.<\/jats:p><\/jats:sec>","DOI":"10.1002\/jmri.27320","type":"journal-article","created":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T11:43:58Z","timestamp":1598615038000},"page":"1311-1317","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Recommendations for Imaging Patients With Cardiac Implantable Electronic Devices (<scp>CIEDs<\/scp>)"],"prefix":"10.1002","volume":"53","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3954-2224","authenticated-orcid":false,"given":"Karl K.","family":"Vigen","sequence":"first","affiliation":[{"name":"Department of Radiology University of Wisconsin\u2010Madison  Madison Wisconsin USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Scott B.","family":"Reeder","sequence":"additional","affiliation":[{"name":"Departments of Radiology, Medical Physics, Biomedical Engineering, Medicine, and Emergency Medicine University of Wisconsin\u2010Madison  Madison Wisconsin USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maureen N.","family":"Hood","sequence":"additional","affiliation":[{"name":"Department of Radiology &amp; Radiological Sciences Uniformed Services University  Bethesda Maryland USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Steckner","sequence":"additional","affiliation":[{"name":"Canon Medical Research USA  Mayfield Village Ohio USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tim","family":"Leiner","sequence":"additional","affiliation":[{"name":"Department of Radiology Utrecht University Medical Center  Utrecht The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David A.","family":"Dombroski","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Rochester Medical Center  Rochester New York USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vikas","family":"Gulani","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Michigan  Ann Arbor Michigan USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"ISMRM Safety Committee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2020,8,17]]},"reference":[{"key":"e_1_2_7_2_1","unstructured":"US Food and Drug Administration. MDR Database Search. Available from:www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfmdr\/search.cfm."},{"key":"e_1_2_7_3_1","unstructured":"US Food and Drug Administration. Device Experience Network (DEN) Reports. Available from:www.fda.gov\/medical-devices\/medical-device-reporting-mdr-how-report-medical-device-problems\/mdr-data-files#den."},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb00202.x"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.11.8077"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000137121.28722.33"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2017.04.025"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2015.09.001"},{"key":"e_1_2_7_9_1","unstructured":"ASTM International. F2503\u201013: Standard practice for marking medical devices and other items for safety in the magnetic resonance environment 2013. Available from:https:\/\/www.astm.org\/Standards\/F2503.htm"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1186\/1532-429X-13-63"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2005.50027.x"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-155-7-201110040-00004"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1604267"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1603265"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2018.02.019"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.107.187256"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.carj.2014.08.001"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0043-102029"},{"key":"e_1_2_7_19_1","unstructured":"British Cardiovascular Society Clinical Imaging Board. Re: MRI for patients with pacemakers and implantable cardioverter\u2010defibrillators \u2013 MRI\u2010conditional and legacy devices 2018. Available from:http:\/\/www.bcs.com\/documents\/2018_letter_RCR_BCS_MRI_for_pacemaker_patients_corrected.pdf."},{"key":"e_1_2_7_20_1","unstructured":"Centers for Medicare & Medicaid Services. Decision memo for magnetic resonance imaging (MRI) 2018. Available from:https:\/\/www.cms.gov\/medicare-coverage-database\/details\/nca-decision-memo.aspx?NCAId=289"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.24011"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.22463"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25106"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2017.10.022"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12213"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euu377"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euq501"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.13130942"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.27320","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jmri.27320","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.27320","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T04:50:17Z","timestamp":1693543817000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.27320"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,17]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021,5]]}},"alternative-id":["10.1002\/jmri.27320"],"URL":"https:\/\/doi.org\/10.1002\/jmri.27320","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,17]]},"assertion":[{"value":"2020-05-26","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-07-22","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-08-17","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}