{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T14:46:29Z","timestamp":1786977989178,"version":"build-2736575974"},"reference-count":29,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2022,12,26]],"date-time":"2022-12-26T00:00:00Z","timestamp":1672012800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2023,9]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Conventional MR pulse sequences result in poor signal from low T2 cortical bone because the minimum achievable echo time is limited. A sequence resulting in improved bone contrast is desirable.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate the image quality and diagnostic performance of grayscale inversion zero echo time imaging (GI\u2010ZTE) and grayscale inversion T1\u2010weighted imaging (GI\u2010T1WI) compared with computed tomography (CT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study Type<\/jats:title>\n                    <jats:p>Prospective.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Subjects<\/jats:title>\n                    <jats:p>A total of 50 patients with musculoskeletal tumors or tumor\u2010like diseases of the lower extremities having MRI and CT studies.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Field Strength\/Sequence<\/jats:title>\n                    <jats:p>GI\u2010T1WI and GI\u2010ZTE sequences at 1.5\u00a0T.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Assessment<\/jats:title>\n                    <jats:p>Assessed cortical and medullary bone morphology abnormalities using CT as the reference standard. Three radiologists scored the images quality and recorded nine metrics to assess the diagnostic performance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Tests<\/jats:title>\n                    <jats:p>\n                      Differences in image quality were calculated using the Wilcoxon signed\u2010rank test. The intraclass correlation coefficient (ICC) was used to analyze the agreement of quantitative lesion parameters between CT and MR sequences, as well as the interobserver reliability. A\n                      <jats:italic>P<\/jats:italic>\n                      value &lt;0.05 was considered statistically significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Image quality score was significantly higher for CT images than GI\u2010TIWI images. Except for radiologist 3 [4(0) vs 4 (1)], there was no significant difference in scores between CT and GI\u2010ZTE [radiologist 1: 4 (0) vs 4 (0),\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0=\u00a00.133; radiologist 2: 4 (0) vs 4 (0),\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0=\u00a00.085]. There was good\u2013excellent agreement between both MR sequences and CT for size, lesion number, location, sclerotic rim, expanded shell, destruction pattern, and matrix mineralization for all radiologists (ICC: 0.636\u20131.000). The consistency of periosteal reaction and penetration of the cortex was fair to good (0.481\u20130.729) between GI\u2010T1WI and CT and good to excellent between GI\u2010ZTE and CT (0.682\u20130.852).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Data Conclusions<\/jats:title>\n                    <jats:p>GI\u2010ZTE images had superior intermodality agreement with CT images and allowed visualization of more cortical bone detail than GI\u2010T1WI images.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Evidence Level<\/jats:title>\n                    <jats:p>1.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technical Efficacy<\/jats:title>\n                    <jats:p>Stage 2.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/jmri.28583","type":"journal-article","created":{"date-parts":[[2022,12,26]],"date-time":"2022-12-26T06:44:24Z","timestamp":1672037064000},"page":"752-760","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Zero Echo Time vs.\n                    <scp>T1<\/scp>\n                    \u2010Weighted\n                    <scp>MRI<\/scp>\n                    for Assessment of Cortical and Medullary Bone Morphology Abnormalities Using\n                    <scp>CT<\/scp>\n                    as the Reference Standard"],"prefix":"10.1002","volume":"58","author":[{"given":"Jun","family":"Xu","sequence":"first","affiliation":[{"name":"Department of Radiology The Affiliated Hospital of Qingdao University  Qingdao Shandong China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yawen","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Radiology The Affiliated Hospital of Qingdao University  Qingdao Shandong China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruizhi","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Radiology The Affiliated Hospital of Qingdao University  Qingdao Shandong China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiqing","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Radiology The Affiliated Hospital of Qingdao University  Qingdao Shandong China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0228-6941","authenticated-orcid":false,"given":"Haisong","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Radiology The Affiliated Hospital of Qingdao University  Qingdao Shandong China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2022,12,26]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mric.2018.06.010"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-018-5450-y"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.22648"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.2906"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bone.2013.01.027"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-003-1902-z"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.rcl.2021.11.003"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11420-014-9403-y"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2463061038"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0033-1343098"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.f2360"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22799"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24816"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2017.2750208"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1148\/rg.220029"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2006.05.014"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-021-05125-5"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000002462"},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2017170906"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.114.149997"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.102B11.BJJ-2020-0383.R1"},{"key":"e_1_2_5_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2021.109915"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-021-08513-5"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-021-03868-8"},{"key":"e_1_2_5_26_1","doi-asserted-by":"publisher","DOI":"10.20982\/tqmp.08.1.p023"},{"key":"e_1_2_5_27_1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546519878170"},{"key":"e_1_2_5_28_1","doi-asserted-by":"publisher","DOI":"10.3389\/fpsyg.2021.637547"},{"key":"e_1_2_5_29_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-018-5889-x"},{"key":"e_1_2_5_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/1522-2586(200012)12:6<814::AID-JMRI4>3.0.CO;2-L"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.28583","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jmri.28583","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.28583","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,18]],"date-time":"2023-08-18T02:57:48Z","timestamp":1692327468000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.28583"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,26]]},"references-count":29,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2023,9]]}},"alternative-id":["10.1002\/jmri.28583"],"URL":"https:\/\/doi.org\/10.1002\/jmri.28583","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,26]]},"assertion":[{"value":"2022-10-30","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-12-15","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-12-26","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}