{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T19:25:07Z","timestamp":1791487507700,"version":"4.3.4"},"reference-count":31,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2027,1,5]],"date-time":"2027-01-05T00:00:00Z","timestamp":1799107200000},"content-version":"am","delay-in-days":365,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#am"},{"start":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T00:00:00Z","timestamp":1767571200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T00:00:00Z","timestamp":1767571200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["P30AG066515\u201006"],"award-info":[{"award-number":["P30AG066515\u201006"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["U01 AG024904"],"award-info":[{"award-number":["U01 AG024904"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000005","name":"U.S. Department of Defense","doi-asserted-by":"publisher","award":["W81XWH\u201012\u20102\u20100012"],"award-info":[{"award-number":["W81XWH\u201012\u20102\u20100012"]}],"id":[{"id":"10.13039\/100000005","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000049","name":"National Institute on Aging","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000049","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000070","name":"National Institute of Biomedical Imaging and Bioengineering","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000070","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006483","name":"AbbVie","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006483","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000957","name":"Alzheimer's Association","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000957","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100002565","name":"Alzheimer's Drug Discovery Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100002565","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100005614","name":"Biogen","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100005614","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004312","name":"Eli Lilly and Company","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004312","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100014400","name":"Fujirebio","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100014400","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006775","name":"GE Healthcare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006775","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100013327","name":"H. Lundbeck A\/S","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100013327","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008272","name":"Novartis Pharmaceuticals Corporation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008272","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100004319","name":"Pfizer","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004319","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100011725","name":"Servier","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100011725","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008373","name":"Takeda Pharmaceutical Company","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100008373","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance Imaging"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Multi\u2010center imaging studies create large\u2010scale data that are useful for identifying pathological patterns and robust training of deep learning models. However, variation due to site and scanner differences can confound analyses, emphasizing the need for harmonization.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To evaluate scanner\u2010related differences in T1w and T2\u2010FLAIR images in the Alzheimer's Disease Neuroimaging Initiative (ADNI) dataset and assess the performance of publicly available image\u2010level harmonization tools.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study Type<\/jats:title>\n                    <jats:p>Retrospective.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Population<\/jats:title>\n                    <jats:p>Scanner group analysis: 1143 ADNI3 subjects (233 GE, 173 Philips, 250 Siemens, with 487 Siemens subjects used as an independent reference group). Within\u2010subject comparison: paired multi\u2010vendor scan sessions from 8 subjects.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Field Strength\/Sequence<\/jats:title>\n                    <jats:p>3.0T, T1w, and T2\u2010FLAIR MRI sequences.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Assessment<\/jats:title>\n                    <jats:p>Gray\/white matter contrast ratio (G\/W ratio), white matter hyperintensity (WMH) volume, and image feature similarity metrics (Fr\u00e9chet Inception Distance [FID], Learned Perceptual Image Patch Similarity [LPIPS]) were compared across scanner vendors before and after harmonization with statistical (ComBat) and deep learning (HACA3) algorithms.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Tests<\/jats:title>\n                    <jats:p>\n                      One\u2010way ANOVA and post hoc Games\u2010Howell tests were conducted to assess differences between scanner groups across image pipelines (baseline, post\u2010harmonization). Repeated\u2010measures ANOVA and post hoc paired\n                      <jats:italic>t<\/jats:italic>\n                      \u2010tests with Bonferroni correction were used to evaluate similarity metric changes pre\u2010 and post\u2010harmonization for multi\u2010vendor subjects. We defined statistical significance as\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>At baseline, significant image differences in G\/W ratio and WMH volumes between vendors were identified. Both ComBat and HACA3 harmonization improved G\/W ratio consistency for T1w and T2\u2010FLAIR imaging across vendors, particularly for GE T2\u2010FLAIRs. HACA3 led to the best similarity between scanner datasets: mean FID T1w\/T2\u2010FLAIR: 10.45\/14.62 (Baseline); 7.45\/11.71 (ComBat); 5.60\/8.91 (HACA3). Only HACA3 harmonization resulted in non\u2010significant differences between vendors for WMH volume.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Data Conclusion<\/jats:title>\n                    <jats:p>HACA3 deep learning harmonization outperformed a statistical method, ComBat, improving MR contrast consistency and feature similarity across vendors. However, difficulties in harmonizing T2\u2010FLAIRs highlight limitations in current multi\u2010contrast MR harmonization tools.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Evidence Level<\/jats:title>\n                    <jats:p>3.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technical Efficacy<\/jats:title>\n                    <jats:p>Stage 1.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/jmri.70221","type":"journal-article","created":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T11:03:07Z","timestamp":1767610987000},"page":"1257-1269","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Evaluation of Image\u2010Level Harmonization Methods for Multi\u2010Center\n                    <scp>MR<\/scp>\n                    Neuroimaging"],"prefix":"10.1002","volume":"63","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-1202-2613","authenticated-orcid":false,"given":"Brandon C.","family":"Ho","sequence":"first","affiliation":[{"name":"Department of Radiology Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5479-2707","authenticated-orcid":false,"given":"Donghoon","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Radiology Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ashwin","family":"Kumar","sequence":"additional","affiliation":[{"name":"Department of Radiology Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Skylar","family":"Weiss","sequence":"additional","affiliation":[{"name":"Department of Neurology and Neurological Sciences Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hillary","family":"Vossler","sequence":"additional","affiliation":[{"name":"Department of Neurology and Neurological Sciences Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Mormino","sequence":"additional","affiliation":[{"name":"Department of Neurology and Neurological Sciences Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5781-8848","authenticated-orcid":false,"given":"Greg","family":"Zaharchuk","sequence":"additional","affiliation":[{"name":"Department of Radiology Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"the Alzheimer's Disease Neuroimaging Initiative","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,1,5]]},"reference":[{"key":"e_1_2_11_2_1","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.0b013e3181cb3e25"},{"key":"e_1_2_11_3_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41586-018-0579-z"},{"key":"e_1_2_11_4_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12938-024-01280-6"},{"key":"e_1_2_11_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compmedimag.2023.102285"},{"key":"e_1_2_11_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2023.120125"},{"key":"e_1_2_11_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000001192"},{"key":"e_1_2_11_8_1","doi-asserted-by":"publisher","DOI":"10.1093\/biostatistics\/kxj037"},{"key":"e_1_2_11_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2017.08.047"},{"key":"e_1_2_11_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2017.11.024"},{"key":"e_1_2_11_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2019.05.041"},{"key":"e_1_2_11_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2021.118569"},{"key":"e_1_2_11_13_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2010.2046908"},{"key":"e_1_2_11_14_1","unstructured":"B. B.Avants N.Tustison andH.Johnson \u201cAdvanced Normalization Tools (ANTS).\u201d"},{"key":"e_1_2_11_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/hbm.24750"},{"key":"e_1_2_11_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/42.906424"},{"key":"e_1_2_11_17_1","unstructured":"M.Heusel H.Ramsauer T.Unterthiner B.Nessler andS.Hochreiter \u201cGANs Trained by a Two Time\u2010Scale Update Rule Converge to a Local Nash Equilibrium \u201d 2018."},{"key":"e_1_2_11_18_1","doi-asserted-by":"crossref","unstructured":"R.Zhang P.Isola A. A.Efros E.Shechtman andO.Wang \u201cThe Unreasonable Effectiveness of Deep Features as a Perceptual Metric \u201d 2018.","DOI":"10.1109\/CVPR.2018.00068"},{"key":"e_1_2_11_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.nicl.2024.103611"},{"key":"e_1_2_11_20_1","doi-asserted-by":"publisher","DOI":"10.4103\/1673-5374.241465"},{"key":"e_1_2_11_21_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13195-020-00669-4"},{"key":"e_1_2_11_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1076-6332(03)00671-8"},{"key":"e_1_2_11_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ynirp.2024.100195"},{"key":"e_1_2_11_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/alz.14358"},{"key":"e_1_2_11_25_1","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A8899"},{"key":"e_1_2_11_26_1","doi-asserted-by":"publisher","DOI":"10.1001\/jamaneurol.2013.1321"},{"key":"e_1_2_11_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0730-725X(03)00173-5"},{"key":"e_1_2_11_28_1","doi-asserted-by":"publisher","DOI":"10.3390\/bioengineering10040397"},{"key":"e_1_2_11_29_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-43715-5"},{"key":"e_1_2_11_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.28887"},{"key":"e_1_2_11_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2023.102926"},{"key":"e_1_2_11_32_1","unstructured":"B.Ho D.Kim A.Kumar andS.Weiss \u201cInter\u2010Scanner Variability and Evaluation of T2\u2010FLAIR Harmonization in Alzheimer's Neuroimaging \u201d2025 ISMRM Annu Meet 2025 (Abstract 3192)."}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.70221","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jmri.70221","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/am-pdf\/10.1002\/jmri.70221","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.70221","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T05:13:04Z","timestamp":1775797984000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.70221"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,5]]},"references-count":31,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["10.1002\/jmri.70221"],"URL":"https:\/\/doi.org\/10.1002\/jmri.70221","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,5]]},"assertion":[{"value":"2025-10-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-16","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-01-05","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}