{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T05:57:13Z","timestamp":1790575033487,"version":"4.1.0"},"reference-count":27,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T00:00:00Z","timestamp":1790467200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T00:00:00Z","timestamp":1790467200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82471973"],"award-info":[{"award-number":["82471973"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005089","name":"Natural Science Foundation of Beijing Municipality","doi-asserted-by":"publisher","award":["7242110"],"award-info":[{"award-number":["7242110"]}],"id":[{"id":"10.13039\/501100005089","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance Imaging"],"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Conventional segmented phase contrast (PC) MRI is the clinical reference standard for cardiovascular hemodynamic quantification, but prolonged acquisition times, mandatory breath\u2010holding, and susceptibility to arrhythmia limit its utility in vulnerable populations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To validate the clinical performance of compressed sensing\u2013accelerated real\u2010time (CSRT) PC MRI with shared velocity encoding (SVE) for fast, free\u2010breathing cardiac flow assessment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study Type<\/jats:title>\n                    <jats:p>Prospective.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Population<\/jats:title>\n                    <jats:p>63 patients (46 male\/17 female, mean age 51.5\u2009\u00b1\u200915.1\u2009years) with diverse cardiac disease.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Field Strength\/Sequence<\/jats:title>\n                    <jats:p>3.0\u2009T; single\u2010shot RF\u2010spoiled gradient echo sequence with SVE (free\u2010breathing CSRT PC MRI) and velocity encoded segmented gradient echo sequence (breath\u2010hold routine segmented (RS) PC MRI).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Assessment<\/jats:title>\n                    <jats:p>Hemodynamic parameters\u2014peak velocity, peak flow rate, net flow rate, and peak mean velocity\u2014were measured at the sinotubular junction plane for both CSRT and RS datasets. Scan time of the two sequences was recorded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Tests<\/jats:title>\n                    <jats:p>\n                      Pearson\/Spearman correlation analysis, intraclass correlation coefficient (ICC), Bland\u2013Altman analysis, paired\n                      <jats:italic>t<\/jats:italic>\n                      \u2010test\/Wilcoxon test. A\n                      <jats:italic>p<\/jats:italic>\n                      value &lt;\u20090.05 was considered significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      RS acquisition time was 16.0\u2009\u00b1\u20092.3\u2009s; total imaging time including breath\u2010hold instructions was 26.0\u2009\u00b1\u20092.3\u2009s, whereas CSRT acquisition time was 10.0\u2009s, yielding a statistically significant difference in scan duration. All hemodynamic parameters demonstrated strong significant correlation between CSRT PC and RS PC MRI (\n                      <jats:italic>r<\/jats:italic>\n                      \u2009\u2265\u20090.89) and good\u2010to\u2010excellent inter\u2010method agreement (ICC\u2009\u2265\u20090.87). CSRT PC yielded significantly lower values for peak velocity (bias\u2009=\u2009\u221216.72\u2009\u00b1\u200911.48\u2009cm\/s [\u221213.31%\u2009\u00b1\u20099.68%]), peak flow rate (bias\u2009=\u2009\u221236.28\u2009\u00b1\u200935.06\u2009mL\/s [\u22129.18%\u2009\u00b1\u20098.98%]), and peak mean velocity (bias\u2009=\u2009\u22126.49\u2009\u00b1\u20097.06\u2009cm\/s [\u221211.02%\u2009\u00b1\u200913.14%]) relative to the RS, but net flow rate was not significantly different between methods (bias\u2009=\u20090.15%\u2009\u00b1\u20090.60\u2009L\/min [4.16%\u2009\u00b1\u200917.28%,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.058]).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Data Conclusions<\/jats:title>\n                    <jats:p>CSRT PC provided satisfactory agreement with conventional RS PC while shortening scan time and enabling free\u2010breathing acquisition.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Evidence Level<\/jats:title>\n                    <jats:p>1.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Technical Efficacy<\/jats:title>\n                    <jats:p>Stage 1.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/jmri.70553","type":"journal-article","created":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T05:44:36Z","timestamp":1790574276000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Compressed Sensing\u2013Accelerated Cartesian Real\u2010Time Phase Contrast\n                    <scp>MRI<\/scp>\n                    With Shared Velocity Encoding: A Clinical Performance Evaluation"],"prefix":"10.1002","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3122-992X","authenticated-orcid":false,"given":"Gang","family":"Yin","sequence":"first","affiliation":[{"name":"Imaging Center, Fuwai Hospital and National Center for Cardiovascular Diseases Peking Union Medical College and Chinese Academy of Medical Sciences  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-2039-1874","authenticated-orcid":false,"given":"Yan","family":"Liang","sequence":"additional","affiliation":[{"name":"Imaging Center, Fuwai Hospital and National Center for Cardiovascular Diseases Peking Union Medical College and Chinese Academy of Medical Sciences  Beijing China"},{"name":"Department of Medical Imaging Wuzhou Workers' Hospital  Wuzhou Guangxi China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mi","family":"Li","sequence":"additional","affiliation":[{"name":"Medical Imaging Center, Shandong Second Provincial General Hospital  Jinan Shandong China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinling","family":"Yang","sequence":"additional","affiliation":[{"name":"Imaging Center, Fuwai Hospital and National Center for Cardiovascular Diseases Peking Union Medical College and Chinese Academy of Medical Sciences  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Chen","sequence":"additional","affiliation":[{"name":"Imaging Center, Fuwai Hospital and National Center for Cardiovascular Diseases Peking Union Medical College and Chinese Academy of Medical Sciences  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1923-2859","authenticated-orcid":false,"given":"Kai","family":"Yang","sequence":"additional","affiliation":[{"name":"Imaging Center, Fuwai Hospital and National Center for Cardiovascular Diseases Peking Union Medical College and Chinese Academy of Medical Sciences  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8996-6623","authenticated-orcid":false,"given":"Chen","family":"Cui","sequence":"additional","affiliation":[{"name":"Imaging Center, Fuwai Hospital and National Center for Cardiovascular Diseases Peking Union Medical College and Chinese Academy of Medical Sciences  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiuyu","family":"Chen","sequence":"additional","affiliation":[{"name":"Imaging Center, Fuwai Hospital and National Center for Cardiovascular Diseases Peking Union Medical College and Chinese Academy of Medical Sciences  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"An","sequence":"additional","affiliation":[{"name":"Siemens Shenzhen Magnetic Resonance Ltd.  Shenzhen China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3925-4441","authenticated-orcid":false,"given":"Giese","family":"Daniel","sequence":"additional","affiliation":[{"name":"Research &amp; Clinical Translation, Magnetic Resonance Siemens Healthineers AG  Erlangen Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ning","family":"Jin","sequence":"additional","affiliation":[{"name":"Siemens Medical Solutions USA, Inc  Chicago Illinois USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1339-7476","authenticated-orcid":false,"given":"Shihua","family":"Zhao","sequence":"additional","affiliation":[{"name":"Imaging Center, Fuwai Hospital and National Center for Cardiovascular Diseases Peking Union Medical College and Chinese Academy of Medical Sciences  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8696-318X","authenticated-orcid":false,"given":"Minjie","family":"Lu","sequence":"additional","affiliation":[{"name":"Imaging Center, Fuwai Hospital and National Center for Cardiovascular Diseases Peking Union Medical College and Chinese Academy of Medical Sciences  Beijing China"},{"name":"Key Laboratory of Cardiovascular Imaging Chinese Academy of Medical Sciences  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,9,27]]},"reference":[{"issue":"36","key":"e_1_2_8_2_1","doi-asserted-by":"crossref","first-page":"3599","DOI":"10.1093\/eurheartj\/ehab368","article-title":"ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure","volume":"42","author":"McDonagh T. A.","year":"2021","journal-title":"European Heart Journal"},{"key":"e_1_2_8_3_1","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2022.826283","article-title":"Cardiac MR: From Theory to Practice","volume":"9","author":"Ismail T. F.","year":"2022","journal-title":"Frontiers in Cardiovascular Medicine"},{"issue":"1","key":"e_1_2_8_4_1","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/s12968-020-00607-1","article-title":"Standardized Cardiovascular Magnetic Resonance Imaging (CMR) Protocols: 2020 Update","volume":"22","author":"Kramer C. M.","year":"2020","journal-title":"Journal of Cardiovascular Magnetic Resonance"},{"issue":"1","key":"e_1_2_8_5_1","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1161\/CIRCIMAGING.112.975623","article-title":"Prospective Comparison of Valve Regurgitation Quantitation by Cardiac Magnetic Resonance Imaging and Transthoracic Echocardiography","volume":"6","author":"Cawley P. J.","year":"2013","journal-title":"Circulation. Cardiovascular Imaging"},{"issue":"4","key":"e_1_2_8_6_1","doi-asserted-by":"crossref","first-page":"445","DOI":"10.3348\/kjr.2016.17.4.445","article-title":"Hemodynamic Measurement Using Four\u2010Dimensional Phase\u2010Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications","volume":"17","author":"Ha H.","year":"2016","journal-title":"Korean Journal of Radiology"},{"issue":"1063","key":"e_1_2_8_7_1","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20150995","article-title":"MR Phase\u2010Contrast Imaging in Pulmonary Hypertension","volume":"89","author":"Reiter U.","year":"2016","journal-title":"British Journal of Radiology"},{"issue":"1","key":"e_1_2_8_8_1","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1148\/rg.2020190039","article-title":"Phase\u2010Contrast MRI: Physics, Techniques, and Clinical Applications","volume":"40","author":"Wymer D. T.","year":"2020","journal-title":"Radiographics"},{"issue":"3","key":"e_1_2_8_9_1","doi-asserted-by":"crossref","first-page":"662","DOI":"10.2214\/AJR.07.3744","article-title":"Cardiovascular Applications of Phase\u2010Contrast MRI","volume":"192","author":"Srichai M. B.","year":"2009","journal-title":"AJR. American Journal of Roentgenology"},{"issue":"3","key":"e_1_2_8_10_1","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.mric.2023.04.005","article-title":"Clinical Applications of Four\u2010Dimensional Flow MRI","volume":"31","author":"Maroun A.","year":"2023","journal-title":"Magnetic Resonance Imaging Clinics of North America"},{"issue":"1","key":"e_1_2_8_11_1","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1186\/s12968-015-0172-7","article-title":"Cardiovascular magnetic resonance phase contrast imaging","volume":"17","author":"Nayak K. S.","year":"2015","journal-title":"Journal of Cardiovascular Magnetic Resonance"},{"issue":"5","key":"e_1_2_8_12_1","doi-asserted-by":"crossref","DOI":"10.1002\/nbm.4240","article-title":"Highly Accelerated, Real\u2010Time Phase\u2010Contrast MRI Using Radial k\u2010Space Sampling and GROG\u2010GRASP Reconstruction: A Feasibility Study in Pediatric Patients With Congenital Heart Disease","volume":"33","author":"Haji\u2010Valizadeh H.","year":"2020","journal-title":"NMR in Biomedicine"},{"key":"e_1_2_8_13_1","first-page":"3252","article-title":"4D Real\u2010Time Phase\u2010Contrast Flow MRI With Sparse Sampling","volume":"2017","author":"Aiqi S.","year":"2017","journal-title":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society"},{"issue":"2","key":"e_1_2_8_14_1","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1002\/mrm.28750","article-title":"Highly Accelerated Free\u2010Breathing Real\u2010Time Phase Contrast Cardiovascular MRI via Complex\u2010Difference Deep Learning","volume":"86","author":"Haji\u2010Valizadeh H.","year":"2021","journal-title":"Magnetic Resonance in Medicine"},{"issue":"3","key":"e_1_2_8_15_1","doi-asserted-by":"crossref","first-page":"1692","DOI":"10.1007\/s00330-023-10157-6","article-title":"Highly Accelerated Free\u2010Breathing Real\u2010Time 2D Flow Imaging Using Compressed Sensing and Shared Velocity Encoding","volume":"34","author":"Xiong F.","year":"2024","journal-title":"European Radiology"},{"issue":"5","key":"e_1_2_8_16_1","doi-asserted-by":"crossref","first-page":"1901","DOI":"10.1002\/mrm.25696","article-title":"Advances in Real\u2010Time Phase\u2010Contrast Flow MRI Using Asymmetric Radial Gradient Echoes","volume":"75","author":"Untenberger M.","year":"2016","journal-title":"Magnetic Resonance in Medicine"},{"issue":"1042","key":"e_1_2_8_17_1","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20140401","article-title":"Real\u2010Time Phase\u2010Contrast Flow MRI of the Ascending Aorta and Superior Vena Cava as a Function of Intrathoracic Pressure (Valsalva Manoeuvre)","volume":"87","author":"Kowallick J. T.","year":"2014","journal-title":"British Journal of Radiology"},{"issue":"1056","key":"e_1_2_8_18_1","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20150487","article-title":"Compressed Sensing MRI: A Review of the Clinical Literature","volume":"88","author":"Jaspan O. N.","year":"2015","journal-title":"British Journal of Radiology"},{"issue":"2","key":"e_1_2_8_19_1","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1002\/jmri.29702","article-title":"Evaluation of Real\u2010Time Cardiovascular Flow MRI Using Compressed Sensing in a Phantom and in Patients With Valvular Disease or Arrhythmia","volume":"62","author":"Lala T.","year":"2025","journal-title":"Journal of Magnetic Resonance Imaging"},{"issue":"2","key":"e_1_2_8_20_1","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research","volume":"15","author":"Koo T. K.","year":"2016","journal-title":"Journal of Chiropractic Medicine"},{"issue":"1","key":"e_1_2_8_21_1","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s12968-017-0330-1","article-title":"Real\u2010Time Phase\u2010Contrast Flow Cardiovascular Magnetic Resonance With Low\u2010Rank Modeling and Parallel Imaging","volume":"19","author":"Sun A.","year":"2017","journal-title":"Journal of Cardiovascular Magnetic Resonance"},{"key":"e_1_2_8_22_1","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1186\/s42490-019-0006-z","article-title":"Compressed Sensing MRI: A Review From Signal Processing Perspective","volume":"1","author":"Ye J. C.","year":"2019","journal-title":"BMC Biomedical Engineering"},{"issue":"6","key":"e_1_2_8_23_1","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1097\/00002142-200012000-00002","article-title":"Ultrafast Pulse Sequence Techniques for Cardiac Magnetic Resonance Imaging","volume":"11","author":"Reeder S. B.","year":"2000","journal-title":"Topics in Magnetic Resonance Imaging"},{"issue":"3","key":"e_1_2_8_24_1","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1002\/mrm.23273","article-title":"Shared Velocity Encoding: A Method to Improve the Temporal Resolution of Phase\u2010Contrast Velocity Measurements","volume":"68","author":"Lin H. Y.","year":"2012","journal-title":"Magnetic Resonance in Medicine"},{"issue":"4","key":"e_1_2_8_25_1","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1007\/s00330-015-3897-7","article-title":"Real\u2010Time Phase Contrast Magnetic Resonance Imaging for Assessment of Haemodynamics: From Phantom to Patients","volume":"26","author":"Traber J.","year":"2016","journal-title":"European Radiology"},{"issue":"5","key":"e_1_2_8_26_1","first-page":"e35","article-title":"ACC\/AHA Guideline for the Management of Patients With Valvular Heart Disease: Executive Summary: A Report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"143","author":"Otto C. M.","year":"2020","journal-title":"Circulation"},{"issue":"5","key":"e_1_2_8_27_1","doi-asserted-by":"crossref","first-page":"564","DOI":"10.21037\/qims.2016.10.06","article-title":"The Effect of Reducing Spatial Resolution by In\u2010Plane Partial Volume Averaging on Peak Velocity Measurements in Phase Contrast Magnetic Resonance Angiography","volume":"6","author":"Rodrigues J.","year":"2016","journal-title":"Quantitative Imaging in Medicine and Surgery"},{"key":"e_1_2_8_28_1","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.clinimag.2022.11.015","article-title":"Real\u2010Time Phase Contrast MRI Versus Conventional Phase Contrast MRI at Different Spatial Resolutions and Velocity Encodings","volume":"94","author":"Liu P.","year":"2023","journal-title":"Clinical Imaging"}],"container-title":["Journal of Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.70553","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jmri.70553","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmri.70553","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T05:44:40Z","timestamp":1790574280000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmri.70553"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,27]]},"references-count":27,"alternative-id":["10.1002\/jmri.70553"],"URL":"https:\/\/doi.org\/10.1002\/jmri.70553","archive":["Portico"],"relation":{},"ISSN":["1053-1807","1522-2586"],"issn-type":[{"value":"1053-1807","type":"print"},{"value":"1522-2586","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,27]]},"assertion":[{"value":"2026-05-19","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-08","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-27","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"jmri.70553"}}