{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T11:49:03Z","timestamp":1782474543198,"version":"3.54.5"},"reference-count":47,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T00:00:00Z","timestamp":1782432000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T00:00:00Z","timestamp":1782432000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Medical Radiation Sci"],"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>Accelerated partial breast irradiation (APBI) delivers a higher dose to a smaller breast volume with equivalent tumour control to whole breast irradiation and improved cosmesis. The MR\u2010Linac offers superior soft tissue visualisation and adaptive planning, but limited bore size may result in skin\u2010couch contact, potentially affecting skin dose. This retrospective pilot study evaluated the effect of MR\u2010Linac couch contact on skin dose. Three patients with left\u2010sided breast cancer positioned prone with unavoidable skin\u2010couch contact were included. MR images were acquired using a 1.5\u2009T MR simulator and contoured for target and organs\u2010at\u2010risk. Step\u2010and\u2010shoot IMRT plans (30Gy in 5 fractions) were optimised and recalculated with and without magnetic field presence. Dose to the whole skin rind (Skin_Rind) and couch\u2010contact region (Skin_Rind_Ant) were compared. All plans met target and OAR constraints. Mean Skin_Rind dose was consistently higher with magnetic field presence, while dose to Skin_Rind_Ant was consistently lower. These findings contrast with conventional linac data, suggesting magnetic field and interface effects may alter skin dose deposition.<\/jats:p>","DOI":"10.1002\/jmrs.70106","type":"journal-article","created":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T11:29:24Z","timestamp":1782473364000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Prone Breast Radiotherapy on the\n                    <scp>MR<\/scp>\n                    \u2010Linac: A Technical Note on Skin\u2010Couch Contact Dose Effects"],"prefix":"10.1002","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8321-815X","authenticated-orcid":false,"given":"Kerryn","family":"Brown","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology ONJ Centre, Austin Health  Heidelberg Victoria Australia"},{"name":"Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences Monash University  Clayton Victoria Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7378-8586","authenticated-orcid":false,"given":"Drew","family":"Smith","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology ONJ Centre, Austin Health  Heidelberg Victoria Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4598-2055","authenticated-orcid":false,"given":"Kristie","family":"Matthews","sequence":"additional","affiliation":[{"name":"School of Primary and Allied Health Care, Faculty of Medicine, Nursing and Health Sciences Monash University, Moorooduc Hwy  Frankston Victoria Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8061-7390","authenticated-orcid":false,"given":"Jessica","family":"Lye","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology ONJ Centre, Austin Health  Heidelberg Victoria Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-8340-8605","authenticated-orcid":false,"given":"Leah","family":"McDermott","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology ONJ Centre, Austin Health  Heidelberg Victoria Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3497-3746","authenticated-orcid":false,"given":"Michael","family":"Chao","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology ONJ Centre, Austin Health  Heidelberg Victoria Australia"},{"name":"Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences Monash University  Clayton Victoria Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8387-0965","authenticated-orcid":false,"given":"Farshad","family":"Foroudi","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology ONJ Centre, Austin Health  Heidelberg Victoria Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6249-3486","authenticated-orcid":false,"given":"Caroline","family":"Wright","sequence":"additional","affiliation":[{"name":"Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences Monash University  Clayton Victoria Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,6,26]]},"reference":[{"issue":"35","key":"e_1_2_12_2_1","doi-asserted-by":"crossref","first-page":"4175","DOI":"10.1200\/JCO.20.00650","article-title":"Accelerated Partial\u2010Breast Irradiation Compared With Whole\u2010Breast Irradiation for Early Breast Cancer: Long Term Results of the Randomized Phase III APBI\u2010IMRT\u2010Florence Trial","volume":"38","author":"Meattini I.","year":"2020","journal-title":"Journal of Clinical Oncology"},{"issue":"10215","key":"e_1_2_12_3_1","doi-asserted-by":"crossref","first-page":"2165","DOI":"10.1016\/S0140-6736(19)32515-2","article-title":"External Beam Accelerated Partial Breast Irradiation Versus Whole Breast Irradiation After Breast Conserving Surgery In Women With Ductal Carcinoma In\u00a0Situ and Node Negative Breast Cancer (RAPID): A Randomised Controlled Trial","volume":"394","author":"Whelan T. J.","year":"2019","journal-title":"Lancet"},{"issue":"10099","key":"e_1_2_12_4_1","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1016\/S0140-6736(17)31145-5","article-title":"Partial Breast Radiotherapy After Breast Conservation Surgery for Patients With Early Breast Cancer (UK IMPORT LOW Trial): 5\u2010Year Results From a Multicentre, Randomised, Controlled, Phase 3, Non\u2010Inferiority Trial","volume":"390","author":"Coles C. E.","year":"2017","journal-title":"Lancet"},{"issue":"4","key":"e_1_2_12_5_1","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1016\/j.ejca.2014.12.013","article-title":"Accelerated Partial Breast Irradiation Using Intensity Modulated Radiotherapy Versus Whole Breast Irradiation: 5\u2010Year Survival Analysis of a Phase 3 Randomised Controlled Trial","volume":"51","author":"Livi L.","year":"2015","journal-title":"European Journal of Cancer"},{"issue":"10015","key":"e_1_2_12_6_1","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/S0140-6736(15)00471-7","article-title":"5\u2010Year Results of Accelerated Partial Breast Irradiation Using Sole Interstitial Multicatheter Brachytherapy Versus Whole\u2010Breast Irradiation With Boost After Breast\u2010Conserving Surgery for Low\u2010Risk Invasive and In\u2010Situ Carcinoma of the Female Breast: A Randomised, Phase 3, Non\u2010Inferiority Trial","volume":"387","author":"Strnad V.","year":"2016","journal-title":"Lancet"},{"issue":"10","key":"e_1_2_12_7_1","doi-asserted-by":"crossref","first-page":"3275","DOI":"10.1245\/s10434-012-2546-5","article-title":"Cost Comparison of Radiation Treatment Options After Lumpectomy for Breast Cancer","volume":"19","author":"Greenup R. A.","year":"2012","journal-title":"Annals of Surgical Oncology"},{"issue":"8","key":"e_1_2_12_8_1","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1016\/j.clon.2015.04.034","article-title":"Examining Determinants of Radiotherapy Access: Do Cost and Radiotherapy Inconvenience Affect Uptake of Breast\u2010Conserving Treatment for Early Breast Cancer?","volume":"27","author":"Lam J.","year":"2015","journal-title":"Clinical Oncology (Royal College of Radiologists)"},{"issue":"23","key":"e_1_2_12_9_1","doi-asserted-by":"crossref","first-page":"L41","DOI":"10.1088\/1361-6560\/aa9517","article-title":"First Patients Treated With a 1.5 T MRI\u2010Linac Clinical Proof of Concept of a High\u2010Precision, High\u2010Field MRI\u2010Guided Radiotherapy Treatment","volume":"62","author":"Raaymakers B. W.","year":"2017","journal-title":"Physics in Medicine and Biology"},{"issue":"2","key":"e_1_2_12_10_1","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/j.radonc.2017.09.009","article-title":"Treating Locally Advanced Lung Cancer With a 1.5T MR\u2010Linac \u2010 Effects of the Magnetic Field and Irradiation Geometry on Conventionally Fractionated and Isotoxic Dose\u2010Escalated Radiotherapy","volume":"125","author":"Bainbridge H. E.","year":"2017","journal-title":"Radiotherapy and Oncology"},{"key":"e_1_2_12_11_1","doi-asserted-by":"crossref","first-page":"7233","DOI":"10.1088\/1361-6560\/aa82ae","article-title":"Towards Fast Online Intrafraction Replanning for Free\u2010Breathing Stereotactic Body Radiation Therapy With the MR\u2010Linac","volume":"62","author":"Kontaxis C.","year":"2017","journal-title":"Physics in Medicine and Biology"},{"key":"e_1_2_12_12_1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.ctro.2018.09.001","article-title":"Single Dose Partial Breast Irradiation Using an MRI Linear Accelerator in the Supine and Prone Treatment Position","volume":"14","author":"Charaghvandi K. R.","year":"2019","journal-title":"Clinical and Translational Radiation Oncology"},{"issue":"2","key":"e_1_2_12_13_1","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/j.ijrobp.2004.04.036","article-title":"Prone Accelerated Partial Breast Irradiation After Breast Conserving Surgery: Preliminary Clinical Results and Dose\u2010Volume Histogram Analysis","volume":"60","author":"Formenti S. C.","year":"2004","journal-title":"International Journal of Radiation Oncology, Biology, Physics"},{"issue":"3","key":"e_1_2_12_14_1","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1016\/j.ijrobp.2007.06.056","article-title":"Intra\u2010 and Interfractional Variations for Prone Breast Irradiation: An Indication for Image Guided Radiotherapy","volume":"69","author":"Morrow N. V.","year":"2007","journal-title":"International Journal of Radiation Oncology, Biology, Physics"},{"key":"e_1_2_12_15_1","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.ejmp.2020.11.031","article-title":"Skin Dose in Radiation Treatment of the Left Breast: Analysis in the Context of Prone Versus Supine Treatment Technique","volume":"81","author":"Singh Saini A.","year":"2021","journal-title":"Physica Medica"},{"issue":"1","key":"e_1_2_12_16_1","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1186\/s12885-016-2794-z","article-title":"Prospective Study of Postoperative Whole Breast Radiotherapy for Japanese Large\u2010Breasted Women: A Clinical and Dosimetric Comparisons Between Supine and Prone Positions and a Dose Measurement Using a Breast Phantom","volume":"16","author":"Takahashi K.","year":"2016","journal-title":"BMC Cancer"},{"issue":"4","key":"e_1_2_12_17_1","doi-asserted-by":"crossref","first-page":"1210","DOI":"10.1016\/j.ijrobp.2016.03.003","article-title":"The 2\u2010Year Cosmetic Outcome of a Randomized Trial Comparing Prone and Supine Whole\u2010Breast Irradiation in Large\u2010Breasted Women","volume":"95","author":"Veldeman L.","year":"2016","journal-title":"International Journal of Radiation Oncology, Biology, Physics"},{"issue":"7","key":"e_1_2_12_18_1","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1001\/jamaoncol.2022.1479","article-title":"Effect of Supine vs Prone Breast Radiotherapy on Acute Toxic Effects of the Skin Among Women With Large Breast Size: A Randomized Clinical Trial","volume":"8","author":"Vesprini D.","year":"2022","journal-title":"JAMA Oncology"},{"issue":"2","key":"e_1_2_12_19_1","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.radonc.2013.08.040","article-title":"Hypofractionated Whole Breast Irradiation for Patients With Large Breasts: A Randomized Trial Comparing Prone and Supine Positions","volume":"108","author":"Mulliez T.","year":"2013","journal-title":"Radiotherapy and Oncology"},{"issue":"3","key":"e_1_2_12_20_1","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.radonc.2006.08.014","article-title":"Prone Breast Irradiation for Pendulous Breasts","volume":"82","author":"Buijsen J.","year":"2007","journal-title":"Radiotherapy and Oncology"},{"key":"e_1_2_12_21_1","doi-asserted-by":"crossref","DOI":"10.1186\/1748-717X-8-232","article-title":"Prone Versus Supine Position for Adjuvant Breast Radiotherapy: A Prospective Study in Patients With Pendulous Breasts","volume":"8","author":"Krengli M.","year":"2013","journal-title":"Radiation Oncology"},{"issue":"3","key":"e_1_2_12_22_1","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/j.adro.2020.02.004","article-title":"Characterization of Respiration Induced Motion in Prone Versus Supine Patient Positioning for Thoracic Radiation Therapy","volume":"5","author":"Guy C. L.","year":"2020","journal-title":"Advances in Radiation Oncology"},{"key":"e_1_2_12_23_1","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.phro.2022.06.015","article-title":"Intrafraction Motion During Radiotherapy of Breast Tumor, Breast Tumor Bed, and Individual Axillary Lymph Nodes on Cine Magnetic Resonance Imaging","volume":"23","author":"Groot Koerkamp M. L.","year":"2022","journal-title":"Physics and Imaging in Radiation Oncology"},{"key":"e_1_2_12_24_1","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.3389\/fonc.2020.01107","article-title":"Optimizing MR\u2010Guided Radiotherapy for Breast Cancer Patients","volume":"10","author":"Groot Koerkamp M. L.","year":"2020","journal-title":"Frontiers in Oncology"},{"key":"e_1_2_12_25_1","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/S0167-8140(97)00118-7","article-title":"The Effect of Carbon Fibre Inserts on the Build\u2010Up and Attenuation of High Energy Photon Beams","volume":"45","author":"De Ost B.","year":"1997","journal-title":"Radiotherapy and Oncology"},{"key":"e_1_2_12_26_1","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1120\/jacmp.v12i4.3554","article-title":"Increased Beam Attenuation and Surface Dose by Different Couch Inserts of Treatment Tables Used in Megavoltage Radiotherapy","volume":"12","author":"Sepp\u00e4l\u00e4 J. K. H.","year":"2011","journal-title":"Journal of Applied Clinical Medical Physics"},{"key":"e_1_2_12_27_1","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/S0958-3947(01)00071-1","article-title":"The Effect of Carbon Fiber Couch Inserts on Surface Dose With Beam Size Variation","volume":"26","author":"Higgins D. M.","year":"2001","journal-title":"Medical Dosimetry"},{"issue":"2","key":"e_1_2_12_28_1","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1120\/jacmp.v11i2.3241","article-title":"Carbon Fibre Couches and Skin Sparing","volume":"11","author":"Court L.","year":"2010","journal-title":"Journal of Applied Clinical Medical Physics"},{"issue":"2","key":"e_1_2_12_29_1","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1118\/1.1852792","article-title":"The Effect of Gantry Angle on Megavoltage Photon Beam Attenuation by a Carbon Fiber Couch Insert","volume":"32","author":"McCormack S.","year":"2005","journal-title":"Medical Physics"},{"issue":"3","key":"e_1_2_12_30_1","article-title":"Skin Dose During Radiotherapy: A Summary and General Estimation Technique","volume":"13","author":"Kry S. F.","year":"2012","journal-title":"Journal of Applied Clinical Medical Physics"},{"issue":"6","key":"e_1_2_12_31_1","doi-asserted-by":"crossref","first-page":"3623","DOI":"10.1002\/mp.16397","article-title":"Magnetic Field Induced Dose Effects in Radiation Therapy Using MR\u2010Linacs","volume":"50","author":"Huang C. Y.","year":"2023","journal-title":"Medical Physics"},{"issue":"6","key":"e_1_2_12_32_1","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1002\/acm2.12182","article-title":"Magnetic Field Dose Effects on Different Radiation Beam Geometries for Hypofractionated Partial Breast Irradiation","volume":"18","author":"Kim A.","year":"2017","journal-title":"Journal of Applied Clinical Medical Physics"},{"issue":"17","key":"e_1_2_12_33_1","doi-asserted-by":"crossref","first-page":"5917","DOI":"10.1088\/0031-9155\/58\/17\/5917","article-title":"MR\u2010Guided Breast Radiotherapy: Feasibility and Magnetic\u2010Field Impact on Skin Dose","volume":"58","author":"Heijst T. C.","year":"2013","journal-title":"Physics in Medicine and Biology"},{"issue":"23","key":"e_1_2_12_34_1","doi-asserted-by":"crossref","first-page":"7045","DOI":"10.1088\/0031-9155\/52\/23\/018","article-title":"Dose Optimization for the MRI\u2010Accelerator: IMRT in the Presence of a Magnetic Field","volume":"52","author":"Raaijmakers A. J.","year":"2007","journal-title":"Physics in Medicine and Biology"},{"issue":"3","key":"e_1_2_12_35_1","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/j.meddos.2020.11.006","article-title":"Dosimetric Impact and Modeling of Prone Breast Positioning Device and Couch Structures","volume":"46","author":"Lau A.","year":"2021","journal-title":"Medical Dosimetry"},{"key":"e_1_2_12_36_1","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.radonc.2019.11.025","article-title":"Partial Breast Irradiation With the 1.5 T MR\u2010Linac: First Patient Treatment and Analysis of Electron Return and Stream Effects","volume":"145","author":"Nachbar M.","year":"2020","journal-title":"Radiotherapy and Oncology"},{"issue":"7","key":"e_1_2_12_37_1","doi-asserted-by":"crossref","first-page":"1363","DOI":"10.1088\/0031-9155\/50\/7\/002","article-title":"Integrating a MRI Scanner With a 6 MV Radiotherapy Accelerator: Dose Increase at Tissue Air Interfaces in a Lateral Magnetic Field due to Returning Electrons","volume":"50","author":"Raaijmakers A. J.","year":"2005","journal-title":"Physics in Medicine and Biology"},{"issue":"1","key":"e_1_2_12_38_1","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1007\/s00066-017-1212-z","article-title":"Air Electron Stream Interactions During Magnetic Resonance IGRT:Skin Irradiation Outside the Treatment Field During Accelerated Partial Breast Irradiation","volume":"194","author":"Park J. M.","year":"2018","journal-title":"Strahlentherapie Und Onkologie"},{"issue":"11","key":"e_1_2_12_39_1","doi-asserted-by":"crossref","first-page":"115029","DOI":"10.1088\/1361-6560\/ab0aa0","article-title":"Monte Carlo Simulations of Out\u2010Of\u2010Field Surface Doses due to the Electron Streaming Effect in Orthogonal Magnetic Fields","volume":"64","author":"Malkov V. N.","year":"2019","journal-title":"Physics in Medicine and Biology"},{"issue":"9","key":"e_1_2_12_40_1","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/aaba8f","article-title":"Spiraling Contaminant Electrons Increase Doses to Surfaces Outside the Photon Beam of an MRI\u2010Linac With a Perpendicular Magnetic Field","volume":"63","author":"Hackett S. L.","year":"2018","journal-title":"Physics in Medicine and Biology"},{"issue":"6","key":"e_1_2_12_41_1","doi-asserted-by":"crossref","first-page":"61501","DOI":"10.1118\/1.4876299","article-title":"Dosimetric Effects Caused by Couch Tops and Immobilization Devices: Report of AAPM Task Group 176","volume":"41","author":"Olch A. J.","year":"2014","journal-title":"Medical Physics"},{"key":"e_1_2_12_42_1","doi-asserted-by":"crossref","DOI":"10.1186\/1748-717X-5-62","article-title":"Treatment Planning Using MRI Data: An Analysis of the Dose Calculation Accuracy for Different Treatment Regions","volume":"5","author":"Jonsson J. H.","year":"2010","journal-title":"Radiation Oncology"},{"issue":"6","key":"e_1_2_12_43_1","doi-asserted-by":"crossref","first-page":"3516","DOI":"10.1118\/1.4925141","article-title":"Use of Tennis Racket and Air Gap Between the Body and Carbon Fiber Couch for Skin Sparing in Radiation Therapy of Prone Breast","volume":"42","author":"Lief E.","year":"2015","journal-title":"Medical Physics"},{"key":"e_1_2_12_44_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.radphyschem.2022.110036","article-title":"Monte Carlo Study of Small\u2010Field Dosimetry for an ELEKTA Unity MR\u2010Linac System","volume":"194","author":"Yano M.","year":"2022","journal-title":"Radiation Physics and Chemistry"},{"issue":"1","key":"e_1_2_12_45_1","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1002\/acm2.12507","article-title":"The Commissioning and Validation of Monaco Treatment Planning System on an Elekta VersaHD Linear Accelerator","volume":"20","author":"Snyder J. E.","year":"2019","journal-title":"Journal of Applied Clinical Medical Physics"},{"issue":"2","key":"e_1_2_12_46_1","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1007\/s13246-019-00749-2","article-title":"Verification of the Elekta Monaco TPS Monte Carlo in Modelling Radiation Transmission Through Metals in a Water Equivalent Phantom","volume":"42","author":"Byrnes K.","year":"2019","journal-title":"Australasian Physical & Engineering Sciences in Medicine"},{"key":"e_1_2_12_47_1","first-page":"54","article-title":"Beam modeling of Elekta Agility MLC for Monte Carlo and Collapsed Cone Convolution computational algorithms in Monaco treatment planning system","volume":"6","author":"Virag V. P.","year":"2022","journal-title":"RAD Conference Proceedings"},{"issue":"2","key":"e_1_2_12_48_1","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1007\/s11547-019-01090-0","article-title":"On the Accuracy of Bulk Synthetic CT for MR\u2010Guided Online Adaptive Radiotherapy","volume":"125","author":"Cusumano D.","year":"2020","journal-title":"La Radiologia Medica"}],"container-title":["Journal of Medical Radiation Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmrs.70106","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jmrs.70106","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmrs.70106","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T11:29:30Z","timestamp":1782473370000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmrs.70106"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,26]]},"references-count":47,"alternative-id":["10.1002\/jmrs.70106"],"URL":"https:\/\/doi.org\/10.1002\/jmrs.70106","archive":["Portico"],"relation":{},"ISSN":["2051-3895","2051-3909"],"issn-type":[{"value":"2051-3895","type":"print"},{"value":"2051-3909","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,26]]},"assertion":[{"value":"2025-09-23","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-17","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-26","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"jmrs.70106"}}