{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T23:39:17Z","timestamp":1792453157187,"version":"4.5.0"},"reference-count":19,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T00:00:00Z","timestamp":1792368000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T00:00:00Z","timestamp":1792368000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["analyticalsciencejournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Mass Spectrom"],"published-print":{"date-parts":[[2026,11]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>A sensitive, selective and rapid liquid chromatography\u2013tandem mass spectrometry (LC\u2013MS\/MS) method was developed and validated for the simultaneous quantification of trace impurities, namely, 2\u2010isoniazid, 3\u2010isoniazid and isonicotinamide, in isoniazid active pharmaceutical ingredient (API) at parts\u2010per\u2010million (ppm) levels. Chromatographic separation was achieved within 6\u2009min using a Zorbax SB Aq column maintained at 40\u00b0C. The mobile phase consisted of 10\u2009mM ammonium formate buffer (pH\u20094.0, adjusted with formic acid) and 0.1% (v\/v) formic acid in acetonitrile (48:52, v\/v), delivered at a flow rate of 1.0\u2009mL\/min. The optimized conditions provided efficient separation, reproducible peak responses and stable ionization for all analytes. The method was validated in accordance with ICH Q2 guidelines with respect to specificity, accuracy, precision, linearity, range, detection limit and quantitation limit. The limits of detection and quantification were established at 0.8\u2009and 2.5\u2009ppm, respectively, demonstrating the high sensitivity of the method for trace impurity determination. The validated method was successfully applied to the analysis of isoniazid bulk drug samples and enabled consistent and accurate quantification of the impurities. The developed LC\u2013MS\/MS method is rapid, robust and suitable for routine quality control testing and regulatory impurity monitoring of isoniazid API.<\/jats:p>","DOI":"10.1002\/jms.70124","type":"journal-article","created":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T22:41:31Z","timestamp":1792449691000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["High\u2010Sensitivity LC\u2013MS\/MS Method for Simultaneous Determination of Structurally Related Impurities 2\u2010Isoniazid, 3\u2010Isoniazid and Isonicotinamide in Isoniazid Active Pharmaceutical Ingredient"],"prefix":"10.1002","volume":"61","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-2137-8623","authenticated-orcid":false,"given":"Rajesh\u00a0Kumar","family":"Boggavarapu","sequence":"first","affiliation":[{"name":"Department of Pharmaceutical Sciences Vignan's Foundation for Science, Technology and Research  Guntur Andhra Pradesh India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5156-6800","authenticated-orcid":false,"given":"Venkateswara\u00a0Rao","family":"Yamarthi","sequence":"additional","affiliation":[{"name":"Department of Pharmaceutical Sciences Vignan's Foundation for Science, Technology and Research  Guntur Andhra Pradesh India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2948-4948","authenticated-orcid":false,"given":"Jithendra","family":"Chimakurthy","sequence":"additional","affiliation":[{"name":"Department of Pharmaceutical Sciences Vignan's Foundation for Science, Technology and Research  Guntur Andhra Pradesh India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,10,19]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1021\/ja073160k"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.3390\/molecules27238607"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.apsb.2016.07.014"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.3389\/fphar.2024.1441147"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpha.2013.09.003"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.trac.2017.09.012"},{"key":"e_1_2_8_8_1","doi-asserted-by":"crossref","DOI":"10.1201\/9781420014549","volume-title":"Liquid Chromatography\u2010Mass Spectrometry","author":"Niessen W. M. A.","year":"2006"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/mas.21585"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpba.2007.03.001"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpba.2016.09.013"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jchromb.2006.09.014"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/1099\u20100801(200010)14:6<422::AID\u2010BMC25>3.0.CO;2\u2010I"},{"key":"e_1_2_8_14_1","doi-asserted-by":"crossref","DOI":"10.1002\/3527604685","volume-title":"Method Validation in Pharmaceutical Analysis: A Guide to Best Practice","author":"Ermer J.","year":"2005"},{"key":"e_1_2_8_15_1","doi-asserted-by":"crossref","unstructured":"ICH \u201cValidation of Analytical Procedures: Text and Methodology Q2(R1) \u201d (2005) https:\/\/doi.org\/10.1002\/jps.2600510933.","DOI":"10.1002\/jps.2600510933"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/ansa.70024"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1146\/annurev.pa.23.040183.001131"},{"key":"e_1_2_8_18_1","doi-asserted-by":"crossref","unstructured":"ICH \u201cImpurities in New Drug Substances Q3A(R2) \u201d International Council for Harmonisation Geneva (2006) https:\/\/doi.org\/10.1002\/jps.2600510933.","DOI":"10.1002\/jps.2600510933"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/jssc.200700483"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00216\u2010009\u20102649\u20104"}],"container-title":["Journal of Mass Spectrometry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jms.70124","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jms.70124","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jms.70124","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T22:41:33Z","timestamp":1792449693000},"score":1,"resource":{"primary":{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/10.1002\/jms.70124"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,19]]},"references-count":19,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["10.1002\/jms.70124"],"URL":"https:\/\/doi.org\/10.1002\/jms.70124","archive":["Portico"],"relation":{},"ISSN":["1076-5174","1096-9888"],"issn-type":[{"value":"1076-5174","type":"print"},{"value":"1096-9888","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,19]]},"assertion":[{"value":"2026-06-11","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-03","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-19","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70124"}}