{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T11:58:08Z","timestamp":1763035088070,"version":"3.40.5"},"reference-count":11,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2021,5,31]],"date-time":"2021-05-31T00:00:00Z","timestamp":1622419200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Medical Virology"],"published-print":{"date-parts":[[2021,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:label\/><jats:p>The current reliable recommended test for coronavirus disease 2019 (COVID\u201019) diagnosis is quantitative reverse\u2010transcription polymerase chain reaction (RT\u2010qPCR). Rapid antigen test devices could be useful as they are less expensive, faster without the need of specialized laboratories to perform the test. We report the performances of two rapid immunochromatographic antigen testing devices compared with RT\u2010qPCR for severe acute respiratory syndrome coronavirus 2 (SARS\u2010CoV\u20102) detection in nasopharyngeal samples. We carried out a lateral\u2010flow tests study on 401 nasopharyngeal swab samples from nonduplicated suspected COVID\u201019 subjects. An equal volume of universal transport medium tubes\u2010containing samples (dilution ratio\u2009=\u20091:15) were added to the manufacturer's extraction buffer solution (dilution ratio\u2009=\u20091:2) and analyzed on BioSpeedia COVID19Speed\u2010Antigen Test and on Abbott Panbio\u2122 COVID\u201019 Ag Rapid Test, devices. Qualitative results were compared to those obtained by the RT\u2010qPCR (Allplex\u2122 SARS\u2010CoV\u20102 Assay Seegene). Based on our data, the overall sensitivity for BioSpeedia and Panbio devices was estimated at 65.5% and 75.0%, respectively. The sensitivity was greater for cycle threshold values less than 25 achieving 90.4 and 96.8 for BioSpeedia and Panbio devices, respectively. A perfect specificity of 100.0% was observed for both devices.<\/jats:p><\/jats:sec>","DOI":"10.1002\/jmv.27094","type":"journal-article","created":{"date-parts":[[2021,5,19]],"date-time":"2021-05-19T16:49:02Z","timestamp":1621442942000},"page":"5655-5659","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Rapid COVID\u201019 antigenic tests: Usefulness of a modified method for diagnosis"],"prefix":"10.1002","volume":"93","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3618-668X","authenticated-orcid":false,"given":"Reza","family":"Soleimani","sequence":"first","affiliation":[{"name":"Department of Laboratory Medicine, Service of Medical Microbiology, CHU UCL Namur Universit\u00e9 Catholique de Louvain  Yvoir Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Corentin","family":"Deckers","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, Service of Medical Microbiology, CHU UCL Namur Universit\u00e9 Catholique de Louvain  Yvoir Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Te\u2010Din","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, Service of Medical Microbiology, CHU UCL Namur Universit\u00e9 Catholique de Louvain  Yvoir Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre","family":"Bogaerts","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, Service of Medical Microbiology, CHU UCL Namur Universit\u00e9 Catholique de Louvain  Yvoir Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"St\u00e9phanie","family":"Evrard","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, Service of Medical Microbiology, CHU UCL Namur Universit\u00e9 Catholique de Louvain  Yvoir Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isaline","family":"Wallemme","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, Service of Medical Microbiology, CHU UCL Namur Universit\u00e9 Catholique de Louvain  Yvoir Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Boutaina","family":"Habib","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, Service of Medical Microbiology, CHU UCL Namur Universit\u00e9 Catholique de Louvain  Yvoir Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pauline","family":"Rouz\u00e9","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, Service of Medical Microbiology, CHU UCL Namur Universit\u00e9 Catholique de Louvain  Yvoir Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olivier","family":"Denis","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine, Service of Medical Microbiology, CHU UCL Namur Universit\u00e9 Catholique de Louvain  Yvoir Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2021,5,31]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.2807\/1560-7917.ES.2020.25.3.2000045"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmv.26430"},{"key":"e_1_2_9_4_1","first-page":"472","article-title":"Field evaluation of a rapid antigen test (Panbio COVID\u201019 Ag Rapid Test Device) for COVID\u201019 diagnosis in primary healthcare centres","volume":"27","author":"Albert E","year":"2020","journal-title":"Clin Microbiol Infect"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.3390\/v12121420"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.4081\/jphr.2020.2011"},{"volume-title":"Designing Clinical Research","year":"2007","author":"Hulley SB","key":"e_1_2_9_7_1"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.2807\/1560-7917.ES.2020.25.3.2000045"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcv.2020.104455"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eclinm.2020.100677"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcv.2020.104659"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10020265"}],"container-title":["Journal of Medical Virology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmv.27094","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jmv.27094","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jmv.27094","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,25]],"date-time":"2023-08-25T16:03:11Z","timestamp":1692979391000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jmv.27094"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,31]]},"references-count":11,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2021,9]]}},"alternative-id":["10.1002\/jmv.27094"],"URL":"https:\/\/doi.org\/10.1002\/jmv.27094","archive":["Portico"],"relation":{},"ISSN":["0146-6615","1096-9071"],"issn-type":[{"type":"print","value":"0146-6615"},{"type":"electronic","value":"1096-9071"}],"subject":[],"published":{"date-parts":[[2021,5,31]]},"assertion":[{"value":"2021-02-09","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-05-17","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-05-31","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}