{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T14:03:47Z","timestamp":1791295427716,"version":"4.1.0"},"reference-count":13,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T00:00:00Z","timestamp":1786492800000},"content-version":"vor","delay-in-days":11,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal of Arrhythmia"],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>VASCADE MVP device has garnered attention as a novel femoral venous closure device. Manual compression (MC) is associated with prolonged bed rest and significant patient discomfort. Although Perclose ProGride\/ProStyle device reduces bed rest duration, it can result in severe puncture site complications. The adoption of VASCADE MVP is anticipated to reduce the incidence of puncture site complications and facilitate early patient mobilization.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A total of 858 patients undergoing catheter ablation were included in this study (MC:\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009196; Perclose:\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009547; VASCADE:\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009115). Perclose device was introduced in January 2018, and VASCADE device in September 2024. Venous closure devices were employed for all suitable femoral puncture sheaths. In the MC group, compression was released after 7\u2009h or the following morning; in the Perclose group after 4\u2009h and in the VASCADE group after three or 4\u2009h. Total post\u2010procedure time and vascular complications were compared among the groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The total post\u2010procedure time was significantly shorter with VASCADE compared to Perclose and MC (22.6\u2009\u00b1\u20098.9\u2009min vs. 29.6\u2009\u00b1\u20098.2\u2009min and 30.4\u2009\u00b1\u20099.3\u2009min,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). The incidence of re\u2010bleeding was comparable between Perclose and VASCADE (11% vs. 13%,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.787). No serious complications were observed in VASCADE group, whereas three patients (1%) in Perclose group experienced major complications.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The use of VASCADE devices safely reduced both total post\u2010procedure time and bedrest times for complete hemostasis, without an associated increase in complications.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/joa3.70442","type":"journal-article","created":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T04:38:23Z","timestamp":1786595903000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Safety and Efficacy of Two Venous Closure Devices Compared With Manual Compression After Atrial Fibrillation Ablation"],"prefix":"10.1002","volume":"42","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-0737-6359","authenticated-orcid":false,"given":"Satoko","family":"Shiomi","sequence":"first","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenichi","family":"Tokutake","sequence":"additional","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ui","family":"Takato","sequence":"additional","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryutaro","family":"Sakurai","sequence":"additional","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshito","family":"Yamazaki","sequence":"additional","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takuya","family":"Matsumoto","sequence":"additional","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidenori","family":"Sato","sequence":"additional","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hirotsuna","family":"Oseto","sequence":"additional","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0890-4189","authenticated-orcid":false,"given":"Masaaki","family":"Yokoyama","sequence":"additional","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seigo","family":"Yamashita","sequence":"additional","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Teiichi","family":"Yamane","sequence":"additional","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michifumi","family":"Tokuda","sequence":"additional","affiliation":[{"name":"Department of Cardiology The Jikei University School of Medicine  Tokyo Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,8,12]]},"reference":[{"key":"e_1_2_13_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/jce.16440"},{"key":"e_1_2_13_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2024.03.033"},{"key":"e_1_2_13_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2019.08.013"},{"key":"e_1_2_13_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-021-00981-5"},{"key":"e_1_2_13_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2023.09.105"},{"key":"e_1_2_13_7_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euad022"},{"key":"e_1_2_13_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/00368504241278481"},{"key":"e_1_2_13_9_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0042-1751230"},{"issue":"4","key":"e_1_2_13_10_1","article-title":"Learning Curve of Perclose ProGlide Utilization During Percutaneous Coronary Intervention","volume":"15","author":"Varis E.","year":"2023","journal-title":"Cureus"},{"key":"e_1_2_13_11_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000104569.96907.7F"},{"key":"e_1_2_13_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/jce.14828"},{"key":"e_1_2_13_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.30405"},{"key":"e_1_2_13_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2021.02.014"}],"container-title":["Journal of Arrhythmia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/joa3.70442","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/joa3.70442","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/joa3.70442","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T13:45:00Z","timestamp":1791294300000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/joa3.70442"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":13,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["10.1002\/joa3.70442"],"URL":"https:\/\/doi.org\/10.1002\/joa3.70442","archive":["Portico"],"relation":{},"ISSN":["1880-4276","1883-2148"],"issn-type":[{"value":"1880-4276","type":"print"},{"value":"1883-2148","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"2026-03-26","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-03","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-12","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70442"}}