{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T11:31:26Z","timestamp":1781004686592,"version":"3.54.1"},"reference-count":42,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2005,2,18]],"date-time":"2005-02-18T00:00:00Z","timestamp":1108684800000},"content-version":"vor","delay-in-days":5588,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal Orthopaedic Research"],"published-print":{"date-parts":[[1989,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The purpose of this study was to evaluate the occurrence of bone ingrowth in a porous coated tibial component of a canine total condylar design knee replacement model. The entire undersurface of the tibial prosthesis was covered by a titanium fiber metal porous composite pad. Projecting from this surface were three short, cylindrical, fiber metal coated pegs that along with a posterior screw provided initial stabilization of the device. Left total knee replacements were performed on six dogs using alignment and cutting jigs to prepare the bony surfaces. The dogs were killed 6 months following surgery. Extensive bone ingrowth was present in all pegs of every tibial component. Bone ingrowth was present in 12% of the pad area of one component, 22.7 to 41.6% in four components, and 81.1% in another. The void spaces in other areas were filled with fibrous tissue or in the periphery of the device with fibrocartilage. Bone ingrowth in the pad was consistent in the vicinity of the pegs and was variable in regions not adjacent to the pegs, suggesting that the pegs exerted a strong influence on the pattern of bone ingrowth into the pad.<\/jats:p>","DOI":"10.1002\/jor.1100070616","type":"journal-article","created":{"date-parts":[[2005,2,24]],"date-time":"2005-02-24T12:37:02Z","timestamp":1109248622000},"page":"893-901","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":41,"title":["Bone ingrowth into the tibial component of a canine total condylar knee replacement prosthesis"],"prefix":"10.1002","volume":"7","author":[{"given":"Thomas M.","family":"Turner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert M.","family":"Urban","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dale R.","family":"Sumner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anastasia K.","family":"Skipor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jorge O.","family":"Galante","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2005,2,18]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1097\/00003086-198206000-00047","article-title":"Biologic fixation and bone remodeling with an unconstrained canine total knee prosthesis","volume":"166","author":"Bobyn JD","year":"1982","journal-title":"Clin Orthop"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453678108991775"},{"key":"e_1_2_1_4_2","first-page":"293","article-title":"Rigidity of initial fixation in non\u2010cemented total knee tibial components","volume":"12","author":"Branson PJ","year":"1987","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820100210"},{"key":"e_1_2_1_6_2","first-page":"261","article-title":"Biologic fixation of tibial components in total knee replacement: the effect of small pegs","volume":"11","author":"Dawson JM","year":"1986","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820110603"},{"key":"e_1_2_1_8_2","first-page":"187","article-title":"An improved technique for methylmethacrylate embedding and toluidine blue\/basic fuchsin staining of undecalcified bone","volume":"12","author":"Dunneisen E","year":"1987","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_9_2","first-page":"137","volume-title":"Advanced Concepts in Total Hip Replacement","author":"Galante JO","year":"1985"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820070305"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197153010-00009"},{"key":"e_1_2_1_12_2","first-page":"236","volume-title":"Total Arthroplasty of the Knee, Proceedings of the Knee Society, 1985\u20131986","author":"Galante JO","year":"1987"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198769090-00026"},{"key":"e_1_2_1_14_2","first-page":"214","volume-title":"The Hip","author":"Harris WH","year":"1985"},{"key":"e_1_2_1_15_2","first-page":"215","volume-title":"Total Arthroplasty of the Knee, Proceedings of the Knee Society, 1985\u20131986","author":"Hungerford DS","year":"1987"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-197209000-00039"},{"key":"e_1_2_1_17_2","first-page":"5","article-title":"Direct observation of micromotion at the implant bone interface with cemented and non\u2010cemented tibial components","volume":"10","author":"Manley MT","year":"1987","journal-title":"Trans Soc Biomater"},{"key":"e_1_2_1_18_2","first-page":"436","article-title":"Direct observation of micromotion at the implant\u2013bone interface with cemented and non\u2010cemented tibial components","volume":"12","author":"Manley MT","year":"1987","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_19_2","first-page":"441","article-title":"The histology of porous coated knee prostheses","volume":"10","author":"Mayor MB","year":"1986","journal-title":"Orthop Trans"},{"key":"e_1_2_1_20_2","first-page":"331","article-title":"The influence of displacement incompatibilities on bone ingrowth in porous tibial components","volume":"13","author":"Natarajan R","year":"1988","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820210116"},{"key":"e_1_2_1_22_2","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1097\/00003086-198607000-00023","article-title":"Observations on the effect of movement on bone ingrowth into porous\u2010surfaced implants","volume":"208","author":"Pilliar RM","year":"1986","journal-title":"Clin Orthop Rel Res"},{"key":"e_1_2_1_23_2","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1097\/00003086-198608000-00037","article-title":"Retrieval analysis of porous\u2010coated components for total knee arthroplasty","volume":"209","author":"Ranawat CS","year":"1986","journal-title":"Clin Orthop"},{"key":"e_1_2_1_24_2","volume-title":"The Hip","author":"Russotti GM","year":"1987"},{"key":"e_1_2_1_25_2","first-page":"217","article-title":"The effect of surgical fit on bone growth into porous coated implants","volume":"12","author":"Sanborn PM","year":"1987","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_26_2","first-page":"1","volume-title":"Methods of Calcified Tissue Preparation","author":"Schenk RK","year":"1981"},{"key":"e_1_2_1_27_2","first-page":"55","volume-title":"Biocompatibility of Orthopedic Implants","author":"Spector M","year":"1982"},{"key":"e_1_2_1_28_2","first-page":"89","volume-title":"Biocompatibility of Orthopedic Implants","author":"Spector M","year":"1982"},{"key":"e_1_2_1_29_2","first-page":"476","article-title":"The initial fixation of porous coated tibial components evaluated by the study of rigid body motion under static load","volume":"13","author":"Strickland AB","year":"1988","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_30_2","first-page":"143","volume-title":"Total Arthroplasty of the Knee, Proceedings of the Knee Society, 1985\u20131986","author":"Stulberg SD","year":"1987"},{"key":"e_1_2_1_31_2","first-page":"431","article-title":"The effect of porous beaded surfaces on metaphyseal bone; the hemiarthroplasty model","volume":"12","author":"Stulberg BN","year":"1987","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_32_2","volume-title":"Surgery of the Musculoskeletal System","author":"Sumner DR"},{"key":"e_1_2_1_33_2","first-page":"580","article-title":"The amount and distribution of bone ingrowth in tibial components retrieved from human patients","volume":"14","author":"Sumner DR","year":"1989","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_34_2","first-page":"509","article-title":"Bone ingrowth in porous\u2010coated cementless acetabular components retrieved from human patients","volume":"12","author":"Sumner DR","year":"1987","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_35_2","first-page":"143","volume-title":"Proceedings of the Symposium on Non\u2010cemented Total Hip Arthroplasty: The Bone Interface","author":"Sumner DR","year":"1988"},{"key":"e_1_2_1_36_2","first-page":"365","article-title":"Bone ingrowth in porous coated cementless femoral stems retrieved from human patients","volume":"13","author":"Sumner DR","year":"1988","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_37_2","first-page":"174","article-title":"Histologic evaluation of tissue growth into retrieved non\u2010cemented Howmedica PCA and Richards Tricon knee components","volume":"9","author":"Thomas KA","year":"1986","journal-title":"Trans Soc Biomater"},{"key":"e_1_2_1_38_2","first-page":"432","article-title":"Histologic analysis of tissue growth into retrieved human total joint components","volume":"12","author":"Thomas KA","year":"1987","journal-title":"Trans Orthop Res Soc"},{"key":"e_1_2_1_39_2","doi-asserted-by":"crossref","first-page":"1396","DOI":"10.2106\/00004623-198668090-00013","article-title":"A comparative study of porous coatings in a weight\u2010bearing total hip\u2010arthroplasty","volume":"68","author":"Turner TM","year":"1986","journal-title":"J Bone Joint Surg [Am]"},{"key":"e_1_2_1_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(76)90013-0"},{"key":"e_1_2_1_41_2","first-page":"381","volume-title":"Tribology of Natural and Artificial Joints","author":"Willert HG","year":"1981"},{"key":"e_1_2_1_42_2","first-page":"205","volume-title":"Total Hip Prostheses","author":"Willert HG","year":"1976"},{"key":"e_1_2_1_43_2","first-page":"49","volume-title":"Biocompatibility of Orthopedic Implants","author":"Williams DF","year":"1982"}],"container-title":["Journal of Orthopaedic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjor.1100070616","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jor.1100070616","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,22]],"date-time":"2023-10-22T00:56:29Z","timestamp":1697936189000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jor.1100070616"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1989,11]]},"references-count":42,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1989,11]]}},"alternative-id":["10.1002\/jor.1100070616"],"URL":"https:\/\/doi.org\/10.1002\/jor.1100070616","archive":["Portico"],"relation":{},"ISSN":["0736-0266","1554-527X"],"issn-type":[{"value":"0736-0266","type":"print"},{"value":"1554-527X","type":"electronic"}],"subject":[],"published":{"date-parts":[[1989,11]]},"assertion":[{"value":"2005-02-18","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}