{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T00:20:45Z","timestamp":1776385245756,"version":"3.51.2"},"reference-count":36,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2007,2,2]],"date-time":"2007-02-02T00:00:00Z","timestamp":1170374400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal Orthopaedic Research"],"published-print":{"date-parts":[[2007,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>We examined a novel mouse model of wear debris\u2010induced prosthesis instability and osteolysis, and its application for the evaluation of therapy. A stainless steel or titanium\u2010alloy pin was implanted into the proximal tibia to form a contiguous surface with the articular cartilage. In some mice, titanium particles were injected into the tibial canal during the surgery, followed by monthly intraarticular injection. MicroCT scans revealed that the implants without particle challenge were stable without bone mineral density changes for 6 months. Histological analysis showed new bone formation around the implant at 6 weeks postsurgery. Periprosthetic soft tissue with inflammatory cells was a ubiquitous finding at the interface between the implant and surrounding bone in samples exposed to titanium particles, and expression of IL\u20101\u03b2, TNF\u03b1, and CD68 was common in these joints. Pullout tests indicated that an average 5N load was required to pull out stable implants from surrounding bone. However, particle stimulation dramatically reduced the pullout force to less than 0.4 N. The feasibility of in vivo gene transfer on this model was confirmed by X\u2010gal staining of synovial membrane and periprosthetic tissue after injection of AAV\u2010LacZ in the prosthetic joint. This murine model of weight\u2010bearing knee prosthesis provides an economical, reproducible, and easily obtained means to study joint arthroplasty failure. The ability to evaluate the biomechanical properties of the prosthetic joint, in addition to histological and biochemical examination, results in a useful model to investigate many of the properties of prosthetic joint components during the response to debris\u2010associated osteolysis. \u00a9 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25:603\u2013611, 2007<\/jats:p>","DOI":"10.1002\/jor.20342","type":"journal-article","created":{"date-parts":[[2007,2,4]],"date-time":"2007-02-04T02:54:11Z","timestamp":1170557651000},"page":"603-611","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":62,"title":["Murine model of prosthesis failure for the long\u2010term study of aseptic loosening"],"prefix":"10.1002","volume":"25","author":[{"given":"Shang\u2010You","family":"Yang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haiying","family":"Yu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weiming","family":"Gong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bin","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lois","family":"Mayton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard","family":"Costello","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul H.","family":"Wooley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2007,2,2]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/s002560050552"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0049-0172(97)80036-4"},{"key":"e_1_2_1_4_2","first-page":"233","article-title":"Current concepts in orthopaedic biomaterials and implant fixation","volume":"43","author":"Friedman RJ","year":"1994","journal-title":"Instr Course Lect"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100150613"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198365050-00001"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00439055"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2004.04064.x"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(98)00216-6"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100180602"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1080\/03009740410005944"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.30441"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.gt.3302192"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1002\/art.10527"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(02)00032-7"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(01)00134-X"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(03)00384-3"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0736-0266(01)00083-3"},{"key":"e_1_2_1_19_2","first-page":"106","article-title":"Aseptic loosening in uncemented total hip arthroplasty in a canine model","volume":"319","author":"Dowd JE","year":"1995","journal-title":"Clin Orthop Relat Res"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0268-0033(03)00138-4"},{"key":"e_1_2_1_21_2","first-page":"161","article-title":"Bone bonding behavior of bead\u2010coated alumina ceramic under load\u2010bearing conditions","volume":"23","author":"Takagi H","year":"1989","journal-title":"J Biomed Mater Res"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199711000-00005"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(93)90241-S"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-002-0451-2"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198870020-00015"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.30120"},{"key":"e_1_2_1_27_2","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1302\/0301-620X.78B1.0780032","article-title":"The effects of particulate polyethylene at a weight\u2010bearing bone\u2010implant interface. A study in rats","volume":"78","author":"Allen M","year":"1996","journal-title":"J Bone Joint Surg [Br]"},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.83B4.10513"},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200202000-00011"},{"key":"e_1_2_1_30_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199707000-00016"},{"key":"e_1_2_1_31_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.76B1.8300684"},{"key":"e_1_2_1_32_2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.80B3.8158"},{"key":"e_1_2_1_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(05)80152-4"},{"key":"e_1_2_1_34_2","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1097\/00003086-199403000-00043","article-title":"The characterization of cytokines in the interface tissue obtained from failed cementless total hip arthroplasty with and without femoral osteolysis","volume":"300","author":"Chiba J","year":"1994","journal-title":"Clin Orthop"},{"key":"e_1_2_1_35_2","doi-asserted-by":"publisher","DOI":"10.3109\/17453679909000980"},{"key":"e_1_2_1_36_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01782811"},{"key":"e_1_2_1_37_2","first-page":"352","article-title":"The synovial response to intraarticular injection in rats of polyethylene wear particles [erratum in Clin Orthop 1994;298:249]","volume":"292","author":"Howie DW","year":"1993","journal-title":"Clin Orthop"}],"container-title":["Journal of Orthopaedic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjor.20342","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jor.20342","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,28]],"date-time":"2023-09-28T16:42:48Z","timestamp":1695919368000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jor.20342"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,2,2]]},"references-count":36,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2007,5]]}},"alternative-id":["10.1002\/jor.20342"],"URL":"https:\/\/doi.org\/10.1002\/jor.20342","archive":["Portico"],"relation":{},"ISSN":["0736-0266","1554-527X"],"issn-type":[{"value":"0736-0266","type":"print"},{"value":"1554-527X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,2,2]]},"assertion":[{"value":"2006-07-13","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2006-10-19","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2007-02-02","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}