{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T18:31:58Z","timestamp":1792693918248,"version":"4.5.0"},"reference-count":34,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2015,9,1]],"date-time":"2015-09-01T00:00:00Z","timestamp":1441065600000},"content-version":"tdm","delay-in-days":651,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Orthop. Res."],"published-print":{"date-parts":[[2014,3]]},"DOI":"10.1002\/jor.22526","type":"journal-article","created":{"date-parts":[[2013,11,19]],"date-time":"2013-11-19T11:58:58Z","timestamp":1384862338000},"page":"369-376","source":"Crossref","is-referenced-by-count":58,"title":["Long-term hip simulator testing of the artificial hip joint bearing surface grafted with biocompatible phospholipid polymer"],"prefix":"10.1002","volume":"32","author":[{"given":"Toru","family":"Moro","sequence":"first","affiliation":[{"name":"Division of Science for Joint Reconstruction; Graduate School of Medicine; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8655 Japan"},{"name":"Sensory & Motor System Medicine; Faculty of Medicine; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8655 Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshio","family":"Takatori","sequence":"additional","affiliation":[{"name":"Division of Science for Joint Reconstruction; Graduate School of Medicine; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8655 Japan"},{"name":"Sensory & Motor System Medicine; Faculty of Medicine; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8655 Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masayuki","family":"Kyomoto","sequence":"additional","affiliation":[{"name":"Division of Science for Joint Reconstruction; Graduate School of Medicine; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8655 Japan"},{"name":"Department of Materials Engineering; School of Engineering; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8656 Japan"},{"name":"Research Department; KYOCERA Medical Corporation; 3-3-31 Miyahara Yodogawa-ku Osaka 532-0003 Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuhiko","family":"Ishihara","sequence":"additional","affiliation":[{"name":"Department of Materials Engineering; School of Engineering; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8656 Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masami","family":"Hashimoto","sequence":"additional","affiliation":[{"name":"Materials Research and Development Laboratory; Japan Fine Ceramics Center; 2-4-1 Mutsuno Atsuta-ku Nagoya 456-8587 Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideya","family":"Ito","sequence":"additional","affiliation":[{"name":"Sensory & Motor System Medicine; Faculty of Medicine; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8655 Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takeyuki","family":"Tanaka","sequence":"additional","affiliation":[{"name":"Sensory & Motor System Medicine; Faculty of Medicine; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8655 Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hirofumi","family":"Oshima","sequence":"additional","affiliation":[{"name":"Sensory & Motor System Medicine; Faculty of Medicine; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8655 Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeyuki","family":"Tanaka","sequence":"additional","affiliation":[{"name":"Sensory & Motor System Medicine; Faculty of Medicine; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8655 Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Kawaguchi","sequence":"additional","affiliation":[{"name":"Sensory & Motor System Medicine; Faculty of Medicine; University of Tokyo; 7-3-1 Hongo Bunkyo-ku Tokyo 113-8655 Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2013,11,19]]},"reference":[{"key":"10.1002\/jor.22526-BIB0001|jor22526-cit-0001","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.2106\/JBJS.D.02441","article-title":"Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002","volume":"87","author":"Kurtz","year":"2005","journal-title":"J Bone Joint Surg Am"},{"key":"10.1002\/jor.22526-BIB0002|jor22526-cit-0002","doi-asserted-by":"crossref","first-page":"128","DOI":"10.2106\/JBJS.H.00155","article-title":"The epidemiology of revision total hip arthroplasty in the United States","volume":"91","author":"Bozic","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"10.1002\/jor.22526-BIB0003|jor22526-cit-0003","first-page":"3","article-title":"Biologic activity of wear particles","volume":"59","author":"Catelas","year":"2010","journal-title":"Instr Course Lect"},{"key":"10.1002\/jor.22526-BIB0004|jor22526-cit-0004","doi-asserted-by":"crossref","first-page":"2262","DOI":"10.1007\/s11999-011-1872-4","article-title":"History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene","volume":"469","author":"Kurtz","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"10.1002\/jor.22526-BIB0005|jor22526-cit-0005","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1243\/0954411021536333","article-title":"Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses","volume":"216","author":"Endo","year":"2002","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1002\/jor.22526-BIB0006|jor22526-cit-0006","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1243\/0954411001535264","article-title":"Boundary lubrication in vivo","volume":"214","author":"Hills","year":"2000","journal-title":"Proc Inst Mech Eng H"},{"key":"10.1002\/jor.22526-BIB0007|jor22526-cit-0007","first-page":"21","article-title":"The morphology and composition of the superficial zone of mammalian articular cartilage","volume":"6","author":"Kirk","year":"1993","journal-title":"J Orthop Rheumatol"},{"key":"10.1002\/jor.22526-BIB0008|jor22526-cit-0008","doi-asserted-by":"crossref","first-page":"2327","DOI":"10.1007\/s11999-010-1718-5","article-title":"Cartilage-mimicking, high-density brush structure improves wear resistance of crosslinked polyethylene: a pilot study","volume":"469","author":"Kyomoto","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"10.1002\/jor.22526-BIB0009|jor22526-cit-0009","doi-asserted-by":"crossref","first-page":"2995","DOI":"10.1016\/j.biomaterials.2009.02.020","article-title":"Wear resistance of artificial hip joints with poly(2-methacryloyloxyethyl phosphorylcholine) grafted polyethylene: comparisons with the effect of polyethylene cross-linking and ceramic femoral heads","volume":"30","author":"Moro","year":"2009","journal-title":"Biomaterials"},{"key":"10.1002\/jor.22526-BIB0010|jor22526-cit-0010","doi-asserted-by":"crossref","first-page":"829","DOI":"10.1038\/nmat1233","article-title":"Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis","volume":"3","author":"Moro","year":"2004","journal-title":"Nat Mater"},{"key":"10.1002\/jor.22526-BIB0011|jor22526-cit-0011","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1295\/polymj.22.355","article-title":"Preparation of phospholipid polymers and their properties as polymer hydrogel membrane","volume":"22","author":"Ishihara","year":"1990","journal-title":"Polym J"},{"key":"10.1002\/jor.22526-BIB0012|jor22526-cit-0012","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1002\/(SICI)1097-4636(199802)39:2<323::AID-JBM21>3.0.CO;2-C","article-title":"Why do phospholipid polymers reduce protein adsorption","volume":"39","author":"Ishihara","year":"1998","journal-title":"J Biomed Mater Res"},{"key":"10.1002\/jor.22526-BIB0013|jor22526-cit-0013","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1163\/156856299X00342","article-title":"Improvement of blood compatibility on cellulose hemodialysis membrane: IV. Phospholipid polymer bonded to the membrane surface","volume":"10","author":"Ishihara","year":"1999","journal-title":"J Biomater Sci Polym Ed"},{"key":"10.1002\/jor.22526-BIB0014|jor22526-cit-0014","doi-asserted-by":"crossref","first-page":"1697","DOI":"10.1016\/S0142-9612(01)00297-6","article-title":"Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and post-implantation","volume":"23","author":"Lewis","year":"2002","journal-title":"Biomaterials"},{"key":"10.1002\/jor.22526-BIB0015|jor22526-cit-0015","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.ajo.2008.07.032","article-title":"Phosphorylcholine impairs susceptibility to biofilm formation of hydrogel contact lenses","volume":"147","author":"Selan","year":"2009","journal-title":"Am J Ophthalmol"},{"key":"10.1002\/jor.22526-BIB0016|jor22526-cit-0016","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1007\/s10856-007-3063-0","article-title":"Effects of photo-induced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on physical properties of cross-linked polyethylene in artificial hip joints","volume":"18","author":"Kyomoto","year":"2007","journal-title":"J Mater Sci Mater Med"},{"key":"10.1002\/jor.22526-BIB0017|jor22526-cit-0017","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1097\/01.blo.0000246553.33434.5f","article-title":"2006 Frank Stinchfield Award: grafting of biocompatible polymer for longevity of artificial hip joints","volume":"453","author":"Moro","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"10.1002\/jor.22526-BIB0018|jor22526-cit-0018","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1002\/jbm.b.30874","article-title":"Enhanced wear resistance of orthopedic bearing due to the cross-linking of poly(MPC) graft chains induced by gamma-ray irradiation","volume":"84","author":"Kyomoto","year":"2008","journal-title":"J Biomed Mater Res Appl Biomater"},{"key":"10.1002\/jor.22526-BIB0019|jor22526-cit-0019","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1002\/jbm.a.31134","article-title":"Enhanced wear resistance of modified cross-linked polyethylene by grafting with poly(2-methacryloyloxyethyl phosphorylcholine)","volume":"82","author":"Kyomoto","year":"2007","journal-title":"J Biomed Mater Res A"},{"key":"10.1002\/jor.22526-BIB0020|jor22526-cit-0020","first-page":"8","article-title":"Forces transmitted by joints in the human body","volume":"181","author":"Paul","year":"1967","journal-title":"Proc Inst Mech Eng"},{"key":"10.1002\/jor.22526-BIB0021|jor22526-cit-0021","doi-asserted-by":"crossref","first-page":"1174","DOI":"10.1016\/j.joca.2010.05.019","article-title":"Surface grafting of biocompatible phospholipid polymer MPC provides wear resistance of tibial polyethylene insert in artificial knee joints","volume":"18","author":"Moro","year":"2010","journal-title":"Osteoarthritis Cartilage"},{"key":"10.1002\/jor.22526-BIB0022|jor22526-cit-0022","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1002\/jbm.a.30824","article-title":"Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators","volume":"78","author":"Tipper","year":"2006","journal-title":"J Biomed Mater Res A"},{"key":"10.1002\/jor.22526-BIB0023|jor22526-cit-0023","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1097\/01.blo.0000238856.61862.7d","article-title":"The basis for a second-generation highly cross-linked UHMWPE","volume":"453","author":"Dumbleton","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"10.1002\/jor.22526-BIB0024|jor22526-cit-0024","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1007\/s11999-010-1555-6","article-title":"Wear versus thickness and other features of 5-Mrad crosslinked UHMWPE acetabular liners","volume":"469","author":"Shen","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"10.1002\/jor.22526-BIB0025|jor22526-cit-0025","doi-asserted-by":"crossref","first-page":"2606","DOI":"10.1007\/s11999-009-0834-6","article-title":"Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030","volume":"467","author":"Kurtz","year":"2009","journal-title":"Clin Orthop Relat Res"},{"key":"10.1002\/jor.22526-BIB0026|jor22526-cit-0026","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.arth.2012.12.005","article-title":"Total hip arthroplasty using highly cross-linked polyethylene in patients younger than 50 years with minimum 10-year follow-up","volume":"28","author":"Babovic","year":"2013","journal-title":"J Arthroplasty"},{"key":"10.1002\/jor.22526-BIB0027|jor22526-cit-0027","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1002\/jbm.a.32092","article-title":"Effects of mobility\/immobility of surface modification by 2-methacryloyloxyethyl phosphorylcholine polymer on the durability of polyethylene for artificial joints","volume":"90","author":"Kyomoto","year":"2009","journal-title":"J Biomed Mater Res A"},{"key":"10.1002\/jor.22526-BIB0028|jor22526-cit-0028","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.2106\/JBJS.K.00570","article-title":"Large femoral heads decrease the incidence of dislocation after total hip arthroplasty","volume":"94","author":"Howie","year":"2012","journal-title":"J Bone Joint Surg Am"},{"key":"10.1002\/jor.22526-BIB0029|jor22526-cit-0029","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1007\/s10047-012-0681-1","article-title":"Poly (2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liner in primary total hip replacement-one-year results of a prospective cohort study","volume":"16","author":"Takatori","year":"2013","journal-title":"J Artif Organs"},{"key":"10.1002\/jor.22526-BIB0030|jor22526-cit-0030","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1016\/j.arth.2007.05.043","article-title":"Highly crosslinked vs conventional polyethylene particles-an in vitro comparison of biologic activities","volume":"23","author":"Illgen","year":"2008","journal-title":"J Arthroplasty"},{"key":"10.1002\/jor.22526-BIB0031|jor22526-cit-0031","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.arth.2009.02.006","article-title":"Hylamer vs conventional polyethylene in primary total hip arthroplasty: a long-term case-control study of wear rates and osteolysis","volume":"25","author":"Huddleston","year":"2010","journal-title":"J Arthroplasty"},{"key":"10.1002\/jor.22526-BIB0032|jor22526-cit-0032","doi-asserted-by":"crossref","first-page":"S111","DOI":"10.5435\/00124635-200800001-00022","article-title":"How have wear testing and joint simulator studies helped to discriminate among materials and designs","volume":"16","author":"McKellop","year":"2008","journal-title":"J Am Acad Orthop Surg"},{"key":"10.1002\/jor.22526-BIB0033|jor22526-cit-0033","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2013.06.001","article-title":"Artificial hip joints: the biomaterials challenge","author":"Pezzotti","year":"2013","journal-title":"J Mech Behav Biomed Mater"},{"key":"10.1002\/jor.22526-BIB0034|jor22526-cit-0034","doi-asserted-by":"crossref","first-page":"1550","DOI":"10.1016\/j.biomaterials.2005.09.010","article-title":"Fatigue crack propagation resistance of virgin and highly crosslinked, thermally treated ultra-high molecular weight polyethylene","volume":"27","author":"Gencur","year":"2006","journal-title":"Biomaterials"}],"container-title":["Journal of Orthopaedic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjor.22526","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full\/10.1002\/jor.22526","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,8,5]],"date-time":"2018-08-05T18:54:57Z","timestamp":1533495297000},"score":1,"resource":{"primary":{"URL":"http:\/\/doi.wiley.com\/10.1002\/jor.22526"}},"subtitle":["BIOCOMPATIBLE POLYMER GRAFTED ARTIFICIAL JOINTS"],"short-title":[],"issued":{"date-parts":[[2013,11,19]]},"references-count":34,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2014,3]]}},"URL":"https:\/\/doi.org\/10.1002\/jor.22526","relation":{},"ISSN":["0736-0266"],"issn-type":[{"value":"0736-0266","type":"print"}],"subject":[],"published":{"date-parts":[[2013,11,19]]}}}