{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,6]],"date-time":"2026-09-06T03:54:51Z","timestamp":1788666891846,"version":"build-2803163510"},"reference-count":31,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2022,10,3]],"date-time":"2022-10-03T00:00:00Z","timestamp":1664755200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R00CA190890"],"award-info":[{"award-number":["R00CA190890"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal Orthopaedic Research"],"published-print":{"date-parts":[[2023,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>High\u2010energy orthopedic injuries cause severe damage to soft tissues and are prone to infection and healing complications, making them a challenge to manage. Further research is facilitated by a clinically relevant animal model with commensurate fracture severity and soft\u2010tissue damage, allowing evaluation of novel treatment options and techniques. Here we report a reproducible, robust, and clinically relevant animal model of high\u2010energy trauma with extensive soft\u2010tissue damage, based on compressed air\u2010driven membrane rupture as the blast wave source. As proof\u2010of\u2010principle showing the reproducibility of the injury, we evaluate changes in tissue and bone perfusion for a range of different tibia fracture severities, using dynamic contrast\u2010enhanced fluorescence imaging and microcomputed tomography. We demonstrate that fluorescence tracer temporal profiles for skin, femoral vein, fractured bone, and paw reflect the increasing impact of more powerful blasts causing a range of Gustilo grade I\u2013III injuries. The maximum fluorescence intensity of distal tibial bone following 0.1\u2009mg\/kg intravenous indocyanine green injection decreased by 35% (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.01), 75% (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), and 87% (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001), following grade I, II, and III injuries, respectively, compared to uninjured bone. Other kinetic parameters of bone and soft tissue perfusion extracted from series of fluorescence images for each animal also showed an association with severity of trauma. In addition, the time\u2010intensity profile of fluorescence showed marked differences in wash\u2010in and wash\u2010out patterns for different injury severities and anatomical locations. This reliable and realistic high\u2010energy trauma model opens new research avenues to better understand infection and treatment strategies.\u00a0Level of evidence: Level III; Case\u2013control.<\/jats:p>","DOI":"10.1002\/jor.25443","type":"journal-article","created":{"date-parts":[[2022,10,4]],"date-time":"2022-10-04T03:44:02Z","timestamp":1664855042000},"page":"1040-1048","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["High\u2010energy open\u2010fracture model with initial experience of fluorescence\u2010guided bone perfusion assessment"],"prefix":"10.1002","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0960-3858","authenticated-orcid":false,"given":"Valentin V.","family":"Demidov","sequence":"first","affiliation":[{"name":"Department of Orthopaedics Dartmouth\u2010Hitchcock Medical Centre Lebanon New Hampshire USA"},{"name":"Geisel School of Medicine Dartmouth College Hanover New Hampshire USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Megan A.","family":"Clark","sequence":"additional","affiliation":[{"name":"Thayer School of Engineering Dartmouth College Hanover New Hampshire USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samuel S.","family":"Streeter","sequence":"additional","affiliation":[{"name":"Thayer School of Engineering Dartmouth College Hanover New Hampshire USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph S.","family":"Sottosanti","sequence":"additional","affiliation":[{"name":"Geisel School of Medicine Dartmouth College Hanover New Hampshire USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ida Leah","family":"Gitajn","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Dartmouth\u2010Hitchcock Medical Centre Lebanon New Hampshire USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan Thomas","family":"Elliott","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Dartmouth\u2010Hitchcock Medical Centre Lebanon New Hampshire USA"},{"name":"Geisel School of Medicine Dartmouth College Hanover New Hampshire USA"},{"name":"Thayer School of Engineering Dartmouth College Hanover New Hampshire USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2022,10,3]]},"reference":[{"key":"e_1_2_10_2_1","first-page":"367","article-title":"High\u2010energy proximal tibial fractures: treatment options and decision making","volume":"55","author":"Tejwani NC","year":"2006","journal-title":"Instr Course Lect"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2006.04.130"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-017-1847-z"},{"issue":"95","key":"e_1_2_10_5_1","first-page":"1","article-title":"Management of high\u2010energy tibial shaft fractures using the hexapod circular external fixator","volume":"21","author":"Liu Y","year":"2021","journal-title":"BMC Surg"},{"issue":"4","key":"e_1_2_10_6_1","first-page":"415","article-title":"Production of a standard experimental fracture","volume":"13","author":"Jackson RW","year":"1970","journal-title":"Can J Surg"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100020115"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199404000-00006"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(77)80044-2"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1159\/000129410"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-018-0128-6"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-019-1386-4"},{"key":"e_1_2_10_13_1","first-page":"63","article-title":"Characteristics on fractures of tibia and fibula in car impacts to pedestrians and bicyclists\u2014influences of car bumper height and shape","volume":"51","author":"Otte D","year":"2007","journal-title":"Annu Proc Assoc Adv Automot Med"},{"key":"e_1_2_10_14_1","first-page":"61","article-title":"An experimental study on air blast injuries","volume":"18","author":"Clemedson CJ","year":"1949","journal-title":"Acta Physiol. Scand, Almqvist & Wiksell"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ta.0000233742.75450.47"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1038\/srep26992"},{"key":"e_1_2_10_17_1","unstructured":"Charlotte Pipe plastics technical and installation manual.\u00a02022. 120 pages.\u00a0https:\/\/www.charlottepipe.com\/Documents\/PL_Tech_Man\/Charlotte_Plastics_Tech_Manual.pdf"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbio.201800427"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.25.6.066002"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.399587"},{"key":"e_1_2_10_21_1","first-page":"1","article-title":"Intraoperative assessment of patient bone viability using texture analysis of dynamic contrast\u2010enhanced fluorescence imaging","volume":"119190","author":"Han X","year":"2021","journal-title":"Proc SPIE"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2012.05.001"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e3182820d31"},{"key":"e_1_2_10_24_1","first-page":"128","volume-title":"Trauma and Orthopaedics at a\u00a0Glance","author":"Willmott H","year":"2016"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-196850040-00001"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/S8756-3282(99)00167-2"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.G.01585"},{"key":"e_1_2_10_28_1","article-title":"Validation of dynamic contrast\u2010enhanced bone blood flow imaging technique with fluorescent microspheres","volume":"11943","author":"Han X","year":"2022","journal-title":"Proc SPIE"},{"key":"e_1_2_10_29_1","first-page":"1","article-title":"Initial experience of perfusion assessment in a rabbit model of orthopaedic trauma surgery using fluorescent microspheres and hyperspectral imaging cryomacrotome","volume":"1214609","author":"Han X","year":"2022","journal-title":"Proc SPIE"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.459497"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.21.8.080901"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e31818e43dd"}],"container-title":["Journal of Orthopaedic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jor.25443","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jor.25443","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jor.25443","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T01:12:28Z","timestamp":1692666748000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jor.25443"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,3]]},"references-count":31,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,5]]}},"alternative-id":["10.1002\/jor.25443"],"URL":"https:\/\/doi.org\/10.1002\/jor.25443","archive":["Portico"],"relation":{},"ISSN":["0736-0266","1554-527X"],"issn-type":[{"value":"0736-0266","type":"print"},{"value":"1554-527X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,3]]},"assertion":[{"value":"2022-06-23","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-09-12","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-10-03","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}