{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T04:49:55Z","timestamp":1791607795226,"version":"4.3.4"},"reference-count":38,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2025,8,28]],"date-time":"2025-08-28T00:00:00Z","timestamp":1756339200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal Orthopaedic Research"],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Markerless motion capture utilizes deep learning models to evaluate standard video from multiple cameras and is significantly more time\u2010efficient than traditional marker\u2010based systems in both setup and analysis. There has been increasing interest in validating markerless motion analysis in the clinical orthopaedic patient population.<\/jats:p><\/jats:sec><jats:sec><jats:title>Purpose<\/jats:title><jats:p>To evaluate the concurrent validity of markerless shoulder analysis compared to traditional marker\u2010based shoulder analysis during activities of daily living (ADLs) in patients with glenohumeral osteoarthritis. We hypothesize that the markerless system will accurately and reliably capture shoulder kinematics in patients with glenohumeral osteoarthritis compared to a marker\u2010based system.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>One hundred subjects, eighty\u2010five patients with glenohumeral osteoarthritis scheduled for shoulder arthroplasty and 15 healthy controls were enrolled in this study. Each patient underwent clinical upper extremity assessment with data being captured concurrently by a traditional marker\u2010based motion capture system and a commercially available markerless system. This study assessed ADLs including four tasks: overhead reaching, drinking, hair brushing, and personal hygiene tasks. Marker\u2010based motion was evaluated with University of Southampton Upper Limb Kinematic Model flexion\u2010based (SF1, SF2) and abduction based (SA1, SA2) models. For each combination of task and laterality, the consistency in response between the markerless system with the SF1, SF2, SA1 and SA2 variations of the marker\u2010based system were investigated by determining the interclass correlation coefficient of the peak angle and range of motion in the three planes of motion: flexion\/extension, abduction\/adduction, and internal rotation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>There was a strong positive relationship between markerless and SF1 and SF2 marker\u2010based models in peak angle (ICC: 0.81\u20130.95; <jats:italic>p<\/jats:italic>\u2010value\u2009&lt;\u20090.001), range of motion (ICC: 0.81\u20130.97; <jats:italic>p<\/jats:italic>\u2010value\u2009&lt;\u20090.001), and shoulder motion pattern (ICC: 0.88\u20130.99; <jats:italic>p<\/jats:italic>\u2010value\u2009&lt;\u20090.001) in flexion\/extension and abduction\/adduction throughout all tasks. There was a weaker positive relationship between markerless and SA1 and SA2 marker\u2010based models in flexion\/extension and abduction\/adduction throughout all tasks (ICC: 0.35\u20130.97; <jats:italic>p<\/jats:italic>\u2010value\u2009&lt;\u20090.001). As forward flexion and abduction angles approached the maximum functional range of the shoulder, there was a weaker but consistent relationship between the two systems.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Markerless motion analysis of the shoulder joint is accurate and has the potential to expand the utility of motion analysis in the upper extremity. Markerless systems were within 10 degrees of both the marker\u2010based and markerless models for flexion\/extension; however, it underestimated rotation movement across all tasks.<\/jats:p><\/jats:sec><jats:sec><jats:title>Clinical Significance<\/jats:title><jats:p>Because markerless motion analysis is cheaper, faster, and easier to implement, it can greatly increase the availability of motion analysis within laboratories and clinical practice and has the potential to become a core component of clinical management of shoulder pathologies.<\/jats:p><\/jats:sec>","DOI":"10.1002\/jor.70047","type":"journal-article","created":{"date-parts":[[2025,8,29]],"date-time":"2025-08-29T01:04:42Z","timestamp":1756429482000},"page":"1907-1923","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Comparison of Markerless and Conventional Marker\u2010Based Shoulder Kinematics Models During Activities of Daily Living in Patients With Glenohumeral Osteoarthritis"],"prefix":"10.1002","volume":"43","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1273-5499","authenticated-orcid":false,"given":"Ram","family":"Haddas","sequence":"first","affiliation":[{"name":"Department of Orthopedics University of Rochester Medical Center Rochester New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas","family":"Morriss","sequence":"additional","affiliation":[{"name":"Department of Orthopedics University of Rochester Medical Center Rochester New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emily","family":"Schillinger","sequence":"additional","affiliation":[{"name":"Department of Orthopedics University of Rochester Medical Center Rochester New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Minto","sequence":"additional","affiliation":[{"name":"Department of Orthopedics University of Rochester Medical Center Rochester New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Castle","sequence":"additional","affiliation":[{"name":"Department of Orthopedics University of Rochester Medical Center Rochester New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dylan N.","family":"Greif","sequence":"additional","affiliation":[{"name":"Department of Orthopedics University of Rochester Medical Center Rochester New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriel","family":"Ramirez","sequence":"additional","affiliation":[{"name":"Department of Orthopedics University of Rochester Medical Center Rochester New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Barber","sequence":"additional","affiliation":[{"name":"Department of Orthopedics University of Rochester Medical Center Rochester New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregg","family":"Nicandri","sequence":"additional","affiliation":[{"name":"Department of Orthopedics University of Rochester Medical Center Rochester New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandeep","family":"Mannava","sequence":"additional","affiliation":[{"name":"Department of Orthopedics University of Rochester Medical Center Rochester New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ilya","family":"Voloshin","sequence":"additional","affiliation":[{"name":"Department of Orthopedics University of Rochester Medical Center Rochester New York USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,8,28]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2023.106029"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2021.110454"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.humov.2019.102562"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s40279-020-01296-7"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2016.06.007"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2018.02.028"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.4055\/cios.2016.8.3.316"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.medntd.2022.100131"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-79707-2"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.3389\/fspor.2022.939980"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bea.2024.100128"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2021.110460"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.7717\/peerj.12995"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-00212-x"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2022.111338"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1093\/ptj\/80.3.276"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.2519\/jospt.2009.2808"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-017-5321-2"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-018-5569-1"},{"key":"e_1_2_10_21_1","article-title":"Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact","volume":"10","author":"Warner M. B.","year":"2015","journal-title":"Journal of Visualized Experiments: JoVE"},{"key":"e_1_2_10_22_1","article-title":"Description, Development and Dissemination of Two Consistent Marker\u2010Based and Markerless Multibody Models","volume":"1","author":"Lahkar B. K.","year":"2022","journal-title":"BioRxiv"},{"key":"e_1_2_10_23_1","first-page":"129","article-title":"Comparison of Concurrent and Asynchronous Running Kinematics and Kinetics From Marker\u2010Based Motion Capture and Markerless Motion Capture Under Two Clothing Conditions","volume":"40","author":"Kanko R. M.","year":"2023","journal-title":"BioRxiv"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2021.110665"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2004.05.042"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/sim.7679"},{"key":"e_1_2_10_27_1","first-page":"306","article-title":"The Reliability and Concurrent Validity of Shoulder Mobility Measurements Using a Digital Inclinometer and Goniometer: A Technical Report","volume":"7","author":"Kolber M. J.","year":"2012","journal-title":"International Journal of Sports Physical Therapy"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-48344-6"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2013.12.015"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2015.03.021"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2011.07.032"},{"key":"e_1_2_10_32_1","first-page":"505","article-title":"Normal Functional Range of Motion of Upper Limb Joints During Performance of Three Feeding Activities","volume":"71","author":"Safaee\u2010Rad R.","year":"1990","journal-title":"Archives of Physical Medicine and Rehabilitation"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2021.110414"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2023.05.029"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1123\/jab.2013-0319"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2004.02.047"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2024.112115"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2023.111645"},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2023.05.029"}],"container-title":["Journal of Orthopaedic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jor.70047","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T10:28:47Z","timestamp":1760005727000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jor.70047"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,28]]},"references-count":38,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2025,11]]}},"alternative-id":["10.1002\/jor.70047"],"URL":"https:\/\/doi.org\/10.1002\/jor.70047","archive":["Portico"],"relation":{},"ISSN":["0736-0266","1554-527X"],"issn-type":[{"value":"0736-0266","type":"print"},{"value":"1554-527X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,28]]},"assertion":[{"value":"2025-04-16","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-31","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-28","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}