{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T06:34:25Z","timestamp":1782974065458,"version":"3.54.5"},"reference-count":34,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T00:00:00Z","timestamp":1781136000000},"content-version":"vor","delay-in-days":10,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal Orthopaedic Research"],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>Locking compression plates (LCPs) offer angular stability and may improve fixation in challenging forearm fractures. Still, they are substantially more expensive than dynamic compression plates (DCPs) or limited contact DCPs (LC\u2010DCPs). This study compared union time, functional outcomes, and complications between LCPs and nonlocking compression plates for diaphyseal radius and ulna fractures. A systematic review and meta\u2010analysis were performed in accordance with PRISMA guidelines. Eligible studies included skeletally mature patients with acute diaphyseal radius and or ulna fractures, compared LCPs with DCPs or LC\u2010DCPs, and reported at least one clinical or radiographic outcome. Primary outcomes were time to union, delayed union, and nonunion. Secondary outcomes included functional scores, range of motion, and complications. Data were pooled using a random\u2010effects model to calculate mean differences or odds ratios with 95% confidence intervals. Eight studies encompassing 525 patients met the inclusion criteria. Five studies comparing LCPs and DCPs showed a significantly shorter mean time to union with LCPs, while rates of delayed union, nonunion, complications, functional scores and range of motion were similar. Three studies compared LCPs and LC\u2010DCPs. LCPs showed a non\u2010significant trend toward shorter union time, with no differences in functional outcomes or complications. In conclusion, LCP fixation results in a modest reduction in time to radiographic union compared with DCPs but does not confer clear advantages in union rates, function, or complications. Given their higher cost and potential challenges at implant removal, LCPs should be used selectively rather than as routine implants for all forearm fractures.<\/jats:p>","DOI":"10.1002\/jor.70237","type":"journal-article","created":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T03:58:04Z","timestamp":1781236684000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Locking Compression Plate Versus Dynamic or Limited Contact Dynamic Compression Plate Fixation for Forearm Fractures: A Systematic Review and Meta\u2010Analysis"],"prefix":"10.1002","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-6980-3797","authenticated-orcid":false,"given":"Ali","family":"Rteil","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery Endeavor Health, an Affiliate of the University of Chicago Pritzker School of Medicine Skokie Illinois USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Majd","family":"Mzeihem","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Illinois at Chicago Chicago Illinois USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brendon","family":"Wang","sequence":"additional","affiliation":[{"name":"Medical College of Wisconsin Milwaukee Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark H.","family":"Gonzalez","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery University of Illinois at Chicago Chicago Illinois USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Farid","family":"Amirouche","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Endeavor Health, an Affiliate of the University of Chicago Pritzker School of Medicine Skokie Illinois USA"},{"name":"Department of Orthopaedic Surgery University of Illinois at Chicago Chicago Illinois USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,6,11]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.5435\/JAAOS-22-07-437"},{"issue":"2","key":"e_1_2_10_3_1","first-page":"159","article-title":"Compression\u2010Plate Fixation of Acute Fractures of the Diaphyses of the Radius and Ulna","volume":"71","author":"Chapman M. W.","year":"1989","journal-title":"Journal of Bone & Joint Surgery"},{"issue":"3","key":"e_1_2_10_4_1","first-page":"433","article-title":"Forearm Fractures: Treatment by Rigid Fixation With Early Motion","volume":"62","author":"Grace T. G.","year":"1980","journal-title":"Journal of Bone & Joint Surgery"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2024.106209"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-198807000-00018"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF00636166"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199707000-00013"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/0020-1383(95)96892-8"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(01)00127-9"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2018.04.031"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1080\/10255842.2014.974580"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.ta.0000195462.53525.0c"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-010-1119-y"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200806000-00007"},{"issue":"2","key":"e_1_2_10_16_1","first-page":"180","article-title":"Plate Osteosynthesis of Simple Forearm Fractures: LCP Versus DC Plates","volume":"74","author":"Stevens C. T.","year":"2008","journal-title":"Acta Orthopaedica Belgica"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.4103\/0019-5413.83762"},{"key":"e_1_2_10_18_1","unstructured":"[Date unknown]. Risk of Bias Tools \u2010 ROBINS\u2010I V2 tool.https:\/\/www.riskofbias.info\/welcome\/robins-i-v2."},{"key":"e_1_2_10_19_1","unstructured":"[Date Unknown]. RoB 2: A Revised Cochrane Risk\u2010of\u2010Bias Tool for Randomized Trials | Cochrane Bias.https:\/\/methods.cochrane.org\/bias\/resources\/rob-2-revised-cochrane-risk-bias-tool-randomized-trials."},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.18203\/issn.2455-4510.IntJResOrthop20171913"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20130624-23"},{"key":"e_1_2_10_22_1","unstructured":"I.Shevate G. L.Patil R.Salunkhe et al. 2022. Dynamic Compression Plate versus Locking Compression Plate Fixation in Adult Forearm Fractures: A Prospective Interventional Study. JCDR [cited November 25 2025] https:\/\/www.jcdr.net\/\/article_fulltext.asp?issn=0973-709x&year=2022&month=August&volume=16&issue=8&page=RC21-RC25&id=16788."},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.12790\/jkssh.2015.20.4.168"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.9790\/0853-0363843"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200409000-00003"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B8.0841093"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.09.024"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2016.04.014"},{"issue":"3","key":"e_1_2_10_29_1","first-page":"287","article-title":"Compression\u2010Plate Fixation in Acute Diaphyseal Fractures of the Radius and Ulna","volume":"57","author":"Anderson L.","year":"1975","journal-title":"Journal of Bone & Joint Surgery"},{"issue":"8","key":"e_1_2_10_30_1","first-page":"1241","article-title":"Refracture of Bones of the Forearm After Plate Removal","volume":"66","author":"Hidaka S.","year":"1984","journal-title":"Journal of Bone & Joint Surgery"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1177\/230949900601400311"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1186\/s10195-025-00823-4"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e318160c84c"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100100115"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.22271\/ortho.2017.v3.i4j.99"}],"container-title":["Journal of Orthopaedic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jor.70237","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jor.70237","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jor.70237","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T05:09:50Z","timestamp":1782968990000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jor.70237"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":34,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["10.1002\/jor.70237"],"URL":"https:\/\/doi.org\/10.1002\/jor.70237","archive":["Portico"],"relation":{},"ISSN":["0736-0266","1554-527X"],"issn-type":[{"value":"0736-0266","type":"print"},{"value":"1554-527X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6]]},"assertion":[{"value":"2026-03-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-22","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-11","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70237"}}