{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T11:27:46Z","timestamp":1787570866189,"version":"build-2736575974"},"reference-count":31,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T00:00:00Z","timestamp":1786924800000},"content-version":"vor","delay-in-days":16,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100005986","name":"Stiftung Endoprothetik","doi-asserted-by":"publisher","award":["S 01\/20"],"award-info":[{"award-number":["S 01\/20"]}],"id":[{"id":"10.13039\/501100005986","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Journal Orthopaedic Research"],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>\n                    Despite promising results of kinematic alignment (KA), there are still concerns regarding the wear behavior of KA knee implants. In a previous study, mechanically aligned (MA), KA and malaligned (MalA) knee implants were tested in a wear simulation study using Attune knee implant systems. The results showed no increased wear rate for a mild KA (KA4\u00b0) and MalA (MalA4\u00b0) condition in comparison to MA (MA0\u00b0) knee implants. This study analyzes the wear behavior of a KA condition of 8\u00b0 (KA8\u00b0). The test setup was adapted accordingly. In addition, all tests of the previous study (MA0\u00b0, MalA4\u00b0 and KA4\u00b0) and the KA8\u00b0 condition were replicated using PFC implant systems to indicate if the previous results can be transferred to the predecessor model of the Attune knee implant system. The KA8\u00b0 using the Attune knee implant system did not lead to a higher wear rate (2.4\u2009\u00b1\u20090.1\u2009mg\/10\n                    <jats:sup>6<\/jats:sup>\n                    cycles) in comparison to the wear results of the previous study (3.8\u2009\u00b1\u20090.5\u2009mg\/10\n                    <jats:sup>6<\/jats:sup>\n                    cycles for MA0\u00b0; 2.7\u2009\u00b1\u20090.2\u2009mg\/10\n                    <jats:sup>6<\/jats:sup>\n                    cycles for MalA4\u00b0 and 4.1\u2009\u00b1\u20090.2\u2009mg\/10\n                    <jats:sup>6<\/jats:sup>\n                    cycles for KA4\u00b0). The PFC implant system led to higher wear rates than the Attune implant system but showed the same trend for the different alignment methods (5.1\u2009\u00b1\u20090.4\u2009mg\/10\n                    <jats:sup>6<\/jats:sup>\n                    cycles for MA0\u00b0; 3.9\u2009\u00b1\u20090.1\u2009mg\/10\n                    <jats:sup>6<\/jats:sup>\n                    cycles for MalA4\u00b0, 5.1\u2009\u00b1\u20090.8\u2009mg\/10\n                    <jats:sup>6<\/jats:sup>\n                    cycles for KA4\u00b0 and 3.5\u2009\u00b1\u20091.0\u2009mg\/10\n                    <jats:sup>6<\/jats:sup>\n                    cycles for KA8\u00b0). KA8\u00b0 did not show wear related problems but further in vitro and in vivo studies are necessary.\n                  <\/jats:p>","DOI":"10.1002\/jor.70265","type":"journal-article","created":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T06:34:24Z","timestamp":1787034864000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["In Vitro Wear Simulation of a Kinematically Aligned Knee Implant Tilted at an Angle of 8\u00b0"],"prefix":"10.1002","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9942-3681","authenticated-orcid":false,"given":"Stefan","family":"Schroeder","sequence":"first","affiliation":[{"name":"Research Center of Biomechanics and Implant Technology, Department of Orthopaedics Heidelberg University Hospital Heidelberg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mareike","family":"Mueller","sequence":"additional","affiliation":[{"name":"Research Center of Biomechanics and Implant Technology, Department of Orthopaedics Heidelberg University Hospital Heidelberg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3519-9307","authenticated-orcid":false,"given":"Maximilian","family":"Uhler","sequence":"additional","affiliation":[{"name":"Research Center of Biomechanics and Implant Technology, Department of Orthopaedics Heidelberg University Hospital Heidelberg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5351-5599","authenticated-orcid":false,"given":"Therese","family":"Bormann","sequence":"additional","affiliation":[{"name":"Research Center of Biomechanics and Implant Technology, Department of Orthopaedics Heidelberg University Hospital Heidelberg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Jaeger","sequence":"additional","affiliation":[{"name":"Research Center of Biomechanics and Implant Technology, Department of Orthopaedics Heidelberg University Hospital Heidelberg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2779-4221","authenticated-orcid":false,"given":"Jan Philippe","family":"Kretzer","sequence":"additional","affiliation":[{"name":"Research Center of Biomechanics and Implant Technology, Department of Orthopaedics Heidelberg University Hospital Heidelberg Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,8,17]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2023.01.060"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-009-1119-9"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2025.02.065"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2018-027812"},{"key":"e_1_2_9_6_1","first-page":"44","article-title":"Kinematic Alignment in Total Knee Arthroplasty. Definition, History, Principle, Surgical Technique, and Results of an Alignment Option for TKA","volume":"1","author":"Howell S. M.","year":"2014","journal-title":"Arthropaedia"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20190424-02"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2020.05.065"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/ksa.12093"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2022.01.052"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-025-05835-7"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.J.00772"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-013-2097-9"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.5312\/wjo.v2.i10.93"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2015.05.016"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/CORR.0000000000002245"},{"key":"e_1_2_9_17_1","volume-title":"ASTM F2003\u201002, Standard Practice for Accelerated Aging of Ultra\u2010High Molecular Weight Polyethylene After Gamma Irradiation in Air","year":"2022"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/2041303310392629"},{"key":"e_1_2_9_19_1","volume-title":"ISO 14243\u20101:2009, Implants for Surgery \u2010 Wear of Total Knee\u2010Joint Prostheses \u2010 Part 1: Loading and Displacement Parameters for Wear\u2010Testing Machines With Load Control and Corresponding Environmental Conditions for Test"},{"key":"e_1_2_9_20_1","volume-title":"ISO 14243\u20102:2009, Implants for Surgery \u2010 Wear of Total Knee\u2010Joint Prostheses \u2010 Part 2: Methods of Measurement"},{"key":"e_1_2_9_21_1","volume-title":"ASTM Standard F1877\u201016, Standard Practice for Characterization of Particles","year":"2016"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.10088"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/1097-4636(200108)56:2<245::AID-JBM1091>3.0.CO;2-T"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2013.07.039"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(98)00140-9"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.34382"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1177\/0954411917746433"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2014.02.052"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.31458"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1177\/1071100718786501"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-014-3813-5"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.21104"}],"container-title":["Journal of Orthopaedic Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jor.70265","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jor.70265","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jor.70265","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T11:15:09Z","timestamp":1787570109000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jor.70265"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":31,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026,8]]}},"alternative-id":["10.1002\/jor.70265"],"URL":"https:\/\/doi.org\/10.1002\/jor.70265","archive":["Portico"],"relation":{},"ISSN":["0736-0266","1554-527X"],"issn-type":[{"value":"0736-0266","type":"print"},{"value":"1554-527X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"2026-03-05","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-08","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-17","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70265"}}