{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T06:58:03Z","timestamp":1761807483818},"reference-count":37,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2009,7,6]],"date-time":"2009-07-06T00:00:00Z","timestamp":1246838400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Surgical Oncology"],"published-print":{"date-parts":[[2009,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>The aim of this study was to analyze the potential utilization of external jugular vein (EJV) cutdown approach for totally implantable venous access device (TIVAD) placement.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This is a prospective, non\u2010randomized, observational, uni\u2010institutional study. All patients (n\u2009=\u2009451) were first subjected to attempted subclavian vein (SV) percutaneous approach. If SV percutaneous approach was unsuccessful after multiple puncture in group A and maximum two puncture in group B, an ipsilateral EJV cutdown approach was attempted.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Four hundred four patients (89.6%) underwent TIVAD placement via SV percutaneous approach. Of those 47 patients in which SV percutaneous approach was not successful, 8 patients in group A and 39 patients in group B, TIVAD was placed via ipsilateral EJV cutdown approach. The avarage of operative time was 17.9\u2009\u00b1\u20098.5\u2009min in group A and 18\u2009\u00b1\u20097.3\u2009min in group B (<jats:italic>P<\/jats:italic>\u2009&gt;\u20090.05). The early complications of group A were significantly higher than that of group B (<jats:italic>P<\/jats:italic>\u2009=\u20090.02).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>TIVAD placement by the SV percutaneous approach is safe and fast, and its success rate is very high. By avoiding the immediate complications associated with the percutaneous approach, the EJV cutdown has to be considered a valid, safe, and suitable alternative when the SV percutaneous approach unsuccessful after two needle puncture. J. Surg. Oncol. 2009;100:279\u2013283. \u00a9 2009 Wiley\u2010Liss, Inc.<\/jats:p><\/jats:sec>","DOI":"10.1002\/jso.21341","type":"journal-article","created":{"date-parts":[[2009,7,7]],"date-time":"2009-07-07T02:19:29Z","timestamp":1246933169000},"page":"279-283","source":"Crossref","is-referenced-by-count":17,"title":["Modification of approach for totally implantable venous access device decreases rate of complications"],"prefix":"10.1002","volume":"100","author":[{"given":"Hasan","family":"Karanlik","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sidika","family":"Kurul","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,7,6]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejso.2007.04.003"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.1999.17.4.1267"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1159\/000011947"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1470-2045(02)00905-1"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/jso.20410"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.6457"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1002\/jso.21064"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/jso.20584"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1186\/1477-7819-2-7"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/jso.21048"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00595-006-3259-9"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9610(96)00198-5"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199412293312602"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1096-9098(199607)62:3<222::AID-JSO14>3.0.CO;2-8"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1002\/jso.2930440112"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1002\/1097-0142(20010901)92:5<1204::AID-CNCR1439>3.0.CO;2-9"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/jso.20771"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9610(05)80773-1"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0142(19970415)79:8<1635::AID-CNCR30>3.0.CO;2-X"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0959-8049(97)89012-0"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1245\/s10434-006-9140-7"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejso.2005.09.004"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjsurg.2005.11.012"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.1002\/jso.2930370413"},{"key":"e_1_2_1_26_2","first-page":"49","article-title":"Placement of central venous catheters by cut\u2010down with electrocardiogram positioning","volume":"177","author":"Redo SF","year":"1993","journal-title":"Surg Gynecol Obstet"},{"key":"e_1_2_1_27_2","first-page":"495","article-title":"Prospective randomised study of cephalic vein cut\u2010down versus subclavian vein puncture technique in the implantation of subcutaneous venous access devices","volume":"54","author":"D'Angelo FA","year":"2002","journal-title":"Chir Ital"},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1245\/ASO.2005.04.028"},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.136.9.1050"},{"key":"e_1_2_1_30_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10434-000-0496-9"},{"key":"e_1_2_1_31_2","doi-asserted-by":"publisher","DOI":"10.1007\/s002689900342"},{"key":"e_1_2_1_32_2","first-page":"15","article-title":"Cephalic vein cutdown for inserting indwelling subclavian vein catheters in gynecologic oncology patients","volume":"98","author":"Kamat A","year":"2002","journal-title":"W V Med J"},{"key":"e_1_2_1_33_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200202000-00031"},{"key":"e_1_2_1_34_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199909000-00019"},{"key":"e_1_2_1_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9610(98)00171-8"},{"key":"e_1_2_1_36_2","doi-asserted-by":"publisher","DOI":"10.1002\/1097-0142(19931001)72:7<2248::AID-CNCR2820720731>3.0.CO;2-U"},{"key":"e_1_2_1_37_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.107.6.1662"},{"key":"e_1_2_1_38_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005382-199701000-00010"}],"container-title":["Journal of Surgical Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjso.21341","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fjso.21341","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jso.21341","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,13]],"date-time":"2023-11-13T18:33:31Z","timestamp":1699900411000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jso.21341"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,7,6]]},"references-count":37,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2009,9]]}},"alternative-id":["10.1002\/jso.21341"],"URL":"https:\/\/doi.org\/10.1002\/jso.21341","archive":["Portico"],"relation":{},"ISSN":["0022-4790","1096-9098"],"issn-type":[{"value":"0022-4790","type":"print"},{"value":"1096-9098","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,7,6]]}}}