{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T10:58:19Z","timestamp":1770721099720,"version":"3.49.0"},"reference-count":18,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2021,1,9]],"date-time":"2021-01-09T00:00:00Z","timestamp":1610150400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Ultrasound Medicine"],"published-print":{"date-parts":[[2021,11]]},"abstract":"<jats:p>Lacrimal canaliculitis (LC) is a rare infection of lacrimal passage, which is usually late diagnosed or misdiagnosed. Traditional lacrimal system tests barely provide a clear and definite understanding of the pathological changes in lacrimal passage. We presented three patients with asymptomatic and atypical symptoms who were misdiagnosed and were eventually diagnosed with chronic LC with assistance of 80\u2010MHz ultrasound biomicroscopy (80\u2010MHz UBM) and lacrimal endoscopy. To our knowledge, the mutual assistance of above two techniques diagnosing LC has never been reported, it can provide better images and observations of the canaliculus from the inside out and can guide the differential diagnosis.<\/jats:p>","DOI":"10.1002\/jum.15625","type":"journal-article","created":{"date-parts":[[2021,1,15]],"date-time":"2021-01-15T00:44:24Z","timestamp":1610671464000},"page":"2513-2520","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Utility of <scp>80\u2010MHz<\/scp> Ultrasound Biomicroscopy and Lacrimal Endoscopy in Chronic Lacrimal Canaliculitis"],"prefix":"10.1002","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1257-2423","authenticated-orcid":false,"given":"Ban","family":"Luo","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Tongji Hospital, Tongji Medical College Huazhong University of Science and Technology  Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Qi","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, the Second Xiangya Hospital Central South University  Changsha China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2021,1,9]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000016789"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000013508"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2010.12.001"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.5935\/0004-2749.20180067"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.3928\/01913913-20130610-02"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joco.2017.06.010"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.4103\/0974-620X.57318"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/IOP.0000000000001275"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.optm.2009.03.016"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajoc.2018.01.004"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-019-04515-8"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-018-4129-z"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/cxo.12914"},{"key":"e_1_2_5_15_1","first-page":"659","article-title":"Diagnosis of lacrimal canalicular diseases using ultrasound biomicroscopy: a preliminary study","volume":"7","author":"Tao H","year":"2014","journal-title":"Int J Ophthalmol"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/IOP.0000000000001419"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000006188"},{"key":"e_1_2_5_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.04.029"},{"key":"e_1_2_5_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2009.01827.x"}],"container-title":["Journal of Ultrasound in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jum.15625","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jum.15625","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jum.15625","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,29]],"date-time":"2023-08-29T15:08:19Z","timestamp":1693321699000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jum.15625"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,9]]},"references-count":18,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2021,11]]}},"alternative-id":["10.1002\/jum.15625"],"URL":"https:\/\/doi.org\/10.1002\/jum.15625","archive":["Portico"],"relation":{},"ISSN":["0278-4297","1550-9613"],"issn-type":[{"value":"0278-4297","type":"print"},{"value":"1550-9613","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,9]]},"assertion":[{"value":"2020-12-11","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-12-14","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-01-09","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}