{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,24]],"date-time":"2025-08-24T01:35:55Z","timestamp":1755999355846,"version":"3.40.5"},"reference-count":34,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2021,4,8]],"date-time":"2021-04-08T00:00:00Z","timestamp":1617840000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Ultrasound Medicine"],"published-print":{"date-parts":[[2022,2]]},"abstract":"<jats:sec><jats:title>Objectives<\/jats:title><jats:p>Semiautomatic fractional limb volume (FLV) models have recently produced promising results for fetal birth weight (BW) estimation. We tested those models in a more unselected population hypothesizing that the FLV models would improve accuracy and precision of fetal BW estimation compared to the Hadlock model.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>We compared the performance of different BW prediction models: Hadlock (biparietal diameter [BPD], abdominal circumference (AC), femur diaphysis length) and modified Lee thigh volume (TVol) and arm volume (AVol) (BPD, AC, automated fractional TVol, and AVol). Accuracy (systematic errors, mean percent differences) and precision (random errors, \u00b1\u20091 SD of percent differences) were calculated.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>A total of 75 fetuses were included for final analysis. The Hadlock model showed the most consistent results with accurate BW estimation not significantly different from zero (\u22120.37\u2009\u00b1\u20098.53%). The modified fractional thigh and arm volume models were less accurate but trended toward more precise results (\u22122.63\u2009\u00b1\u20097.69% and \u22123.85\u2009\u00b1\u20097.47%, respectively). In addition, the modified TVol model showed the trend to predict more BWs within \u00b110% of the actual BW compared to the Hadlock model (81.3 versus 74.67%, ns).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Based on our results, fetal weight estimation using the modified semiautomatic FLV models generates less accurate results in third\u2010trimester fetuses compared to the Hadlock model. Those models recently published might improve the results of BW prediction by showing a higher precision than conventional models, especially in small and large fetuses. Further studies are needed to investigate the clinical usefulness of the new models.<\/jats:p><\/jats:sec>","DOI":"10.1002\/jum.15712","type":"journal-article","created":{"date-parts":[[2021,4,8]],"date-time":"2021-04-08T11:37:27Z","timestamp":1617881847000},"page":"355-364","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Semiautomatic Assessment of Fetal Fractional Limb Volume for Weight Prediction in Clinical Praxis"],"prefix":"10.1002","volume":"41","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6405-2166","authenticated-orcid":false,"given":"Michael","family":"Gembicki","sequence":"first","affiliation":[{"name":"Department of Gynecology and Obstetrics, Division of Prenatal Medicine University Hospital of Schleswig\u2010Holstein  Luebeck Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David R.","family":"Offerman","sequence":"additional","affiliation":[{"name":"Department of Gynecology and Obstetrics, Division of Prenatal Medicine University Hospital of Schleswig\u2010Holstein  Luebeck Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Weichert","sequence":"additional","affiliation":[{"name":"Department of Gynecology and Obstetrics, Division of Prenatal Medicine University Hospital of Schleswig\u2010Holstein  Luebeck Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2021,4,8]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1093\/ije\/30.6.1233"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2017-1881"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.7863\/jum.2009.28.5.617"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.181.1.1887021"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.7863\/jum.2001.20.12.1283"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.7863\/ultra.16.08087"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0029-7844(97)00280-9"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9378(97)70157-1"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.5181"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.6319"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.7327"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.11185"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.7863\/jum.2009.28.3.309"},{"key":"e_1_2_7_15_1","first-page":"1580","article-title":"Fractional thigh volume by three\u2010dimensional ultrasonography for birth weight prediction","volume":"92","author":"Srisantiroj N","year":"2009","journal-title":"J Med Assoc Thai"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.8945"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1159\/000360417"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.12458"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.7863\/ultra.15.06106"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/jum.15105"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.7863\/ultra.15.09086"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/jum.15224"},{"key":"e_1_2_7_23_1","article-title":"Fetal weight estimation using automated fractional limb volume with 2\u2010dimensional size parameters in diabetic pregnancies","volume":"40","author":"Lee W","year":"2020","journal-title":"J Ultrasound Med"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.7654"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1093\/aje\/kwj237"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.20279"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.20162"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1097\/AOG.0000000000001767"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.20272"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/ijgo.12770"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.1751"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/uog.20185"},{"key":"e_1_2_7_33_1","first-page":"561","article-title":"Influence of fetal fat on the ultrasound estimation of fetal weight in diabetic mothers","volume":"79","author":"Bernstein IM","year":"1992","journal-title":"Obstet Gynecol"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1159\/000500452"},{"key":"e_1_2_7_35_1","article-title":"A routine third trimester growth ultrasound in the obese pregnant woman does not reliably identify fetal growth abnormalities: a retrospective cohort study","volume":"61","author":"Neel A","year":"2020","journal-title":"Aust N Z J Obstet Gynaecol"}],"container-title":["Journal of Ultrasound in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jum.15712","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/jum.15712","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/jum.15712","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T08:58:15Z","timestamp":1693213095000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/jum.15712"}},"subtitle":["How Does It Perform in Routine Use?"],"short-title":[],"issued":{"date-parts":[[2021,4,8]]},"references-count":34,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022,2]]}},"alternative-id":["10.1002\/jum.15712"],"URL":"https:\/\/doi.org\/10.1002\/jum.15712","archive":["Portico"],"relation":{},"ISSN":["0278-4297","1550-9613"],"issn-type":[{"type":"print","value":"0278-4297"},{"type":"electronic","value":"1550-9613"}],"subject":[],"published":{"date-parts":[[2021,4,8]]},"assertion":[{"value":"2020-12-11","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-03-17","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-04-08","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}