{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T14:16:44Z","timestamp":1790864204792,"version":"4.1.0"},"reference-count":25,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2011,5,3]],"date-time":"2011-05-03T00:00:00Z","timestamp":1304380800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Laryngoscope"],"published-print":{"date-parts":[[2011,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Objectives\/Hypothesis:<\/jats:title><jats:p>To compare electrode array position, and depth of insertion of the Cochlear Hybrid\u2010L24\u00ae electrode array following traditional cochleostomy and round window (RW) insertion.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study Design:<\/jats:title><jats:p>Prospective cadaveric temporal bone study.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods:<\/jats:title><jats:p>Ten cadaveric temporal bones were implanted with the Hybrid\u2010L24\u00ae electrode array; half were introduced through a RW approach, whereas the other half were inserted through a traditional scala tympani cochleostomy. A micro\u2010CT scanner was then used to evaluate electrode position, intracochlear trauma, and depth of insertion.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results:<\/jats:title><jats:p>All electrodes were inserted into the scala tympani without significant resistance. No electrodes demonstrated tip fold\u2010over or through\u2010fracturing of the osseous spiral lamina, basilar membrane, or spiral ligament. The average angular depth of insertion for all 10 electrodes was 252.4\u00b0. Compared to cochleostomy insertions, electrodes inserted through the RW more commonly acquired a proximal perimodiolar orientation, followed a more predictable course, and less commonly contacted critical soft tissue structures.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions:<\/jats:title><jats:p>The results of this study demonstrate that the Hybrid\u2010L24\u00ae electrode can be successfully inserted using a RW or traditional cochleostomy technique with minimal intracochlear trauma. Our data also suggests that with this model, RW insertions may provide particular advantages with respect to hearing preservation over the traditional cochleostomy approach. Laryngoscope, 2011<\/jats:p><\/jats:sec>","DOI":"10.1002\/lary.21837","type":"journal-article","created":{"date-parts":[[2011,4,27]],"date-time":"2011-04-27T15:25:57Z","timestamp":1303917957000},"page":"1508-1516","source":"Crossref","is-referenced-by-count":15,"title":["Evaluation of the hybrid\u2010L24\u00ae electrode using microcomputed tomography"],"prefix":"10.1002","volume":"121","author":[{"given":"Colin L.W.","family":"Driscoll","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew L.","family":"Carlson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony F.","family":"Fama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John I.","family":"Lane","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2011,5,3]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.mlg.0000167993.05007.35"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1080\/00016480510031489"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.mao.0000244355.34577.85"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.MLG.0000157695.07536.D2"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1159\/000206492"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1159\/000027695"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-200310000-00012"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1159\/000206493"},{"key":"e_1_2_6_10_2","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1159\/000094642","article-title":"Surgical aspects of cochlear implantation: mechanisms of insertional trauma","volume":"64","author":"Roland PS","year":"2006","journal-title":"Adv Oto\u2010rhino\u2010laryngol"},{"key":"e_1_2_6_11_2","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1177\/00034894071160S401","article-title":"In vivo estimates of the position of advanced bionics electrode arrays in the human cochlea","volume":"197","author":"Skinner MW","year":"2007","journal-title":"Ann Otology Rhinol Laryngol"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.MLG.0000181461.63392.49"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.mao.0000187047.58544.d0"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e31816845eb"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1159\/000095613"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1080\/00016480500437377"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.mao.0000247817.31572.ed"},{"key":"e_1_2_6_18_2","volume-title":"Pathology of the Ear","author":"Schuknecht H","year":"1976"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1159\/000095612"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.2007.08.0119"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1002\/cii.45"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1096-9861(19991004)412:4<543::AID-CNE1>3.0.CO;2-3"},{"key":"e_1_2_6_23_2","first-page":"8","article-title":"The biologic safety of the Cochlear Corporation multiple\u2010electrode intracochlear implant","volume":"9","author":"Webb RL","year":"1988","journal-title":"Am J Otol"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1080\/00016480410018179"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/MLG.0b013e318064e891"},{"key":"e_1_2_6_26_2","first-page":"309","article-title":"The topographical anatomy of the round window and related structures for the purpose of cochlear implant surgery","volume":"63","author":"Paprocki A","year":"2004","journal-title":"Folia Morphol"}],"container-title":["The Laryngoscope"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Flary.21837","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Flary.21837","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/lary.21837","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T16:38:15Z","timestamp":1697474295000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/lary.21837"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,5,3]]},"references-count":25,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2011,7]]}},"alternative-id":["10.1002\/lary.21837"],"URL":"https:\/\/doi.org\/10.1002\/lary.21837","archive":["Portico"],"relation":{},"ISSN":["0023-852X","1531-4995"],"issn-type":[{"value":"0023-852X","type":"print"},{"value":"1531-4995","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,5,3]]}}}