{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T22:12:20Z","timestamp":1790719940616,"version":"4.1.0"},"reference-count":65,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2017,4,11]],"date-time":"2017-04-11T00:00:00Z","timestamp":1491868800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Laryngoscope"],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:sec><jats:title>Objectives<\/jats:title><jats:p>To determine if high\u2010resolution T2\u2010weighted (HRT2) magnetic resonance imaging (MRI) is a comparably accurate and economical alternative to the gold standard of contrast\u2010enhanced T1\u2010weighted (T1C) MRI for surveillance of know vestibular schwannomas (VSs).<\/jats:p><\/jats:sec><jats:sec><jats:title>Study Design<\/jats:title><jats:p>Retrospective case\u2010control analysis, systematic review, and economic evaluation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Vestibular schwannoma size in anteroposterior, mediolateral, and superoinferior axes were measured by two neuroradiologists, both blinded to previous measurements, for 50 randomized patients with T1C and HRT2 on two separate occasions. Measurements were assessed by Pearson product\u2010moment correlation coefficients, and differences were analyzed by Student<jats:italic>t<\/jats:italic>test. Once the data were analyzed, appropriate economic evaluation was performed utilizing institutional\u2010, federal\u2010, and literature\u2010based estimates of cost and incidence\/prevalence.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Pearson correlations (<jats:italic>r<\/jats:italic>) between T1C and HRT2 were 0.991 and 0.973 for radiologists 1 and 2, respectively, with no statistically significant differences (<jats:italic>P<\/jats:italic>\u2264 0.05) between imaging techniques. Intraobserver and interobserver reliability estimates (\u03ba) were 0.88 to 1 for both T1C and HRT2, indicating very high reliability. Cost\u2010minimization analysis demonstrated cost and charge differences of $148.02 and $1,284 per patient per scan, respectively. This represents an overall cost and charge savings for this 50\u2010patient cohort of $7,401 and $64,200, respectively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>HRT2 imaging is a highly reliable and lower\u2010cost alternative to T1C for follow\u2010up surveillance scans in patients with VS.<\/jats:p><\/jats:sec><jats:sec><jats:title>Level of Evidence<\/jats:title><jats:p>2C.<jats:italic>Laryngoscope<\/jats:italic>, 128:202\u2013209, 2018<\/jats:p><\/jats:sec>","DOI":"10.1002\/lary.26589","type":"journal-article","created":{"date-parts":[[2017,4,11]],"date-time":"2017-04-11T06:04:09Z","timestamp":1491890649000},"page":"202-209","source":"Crossref","is-referenced-by-count":54,"title":["MRI surveillance of vestibular schwannomas without contrast enhancement: Clinical and economic evaluation"],"prefix":"10.1002","volume":"128","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6485-2075","authenticated-orcid":false,"given":"Daniel H.","family":"Coelho","sequence":"first","affiliation":[{"name":"Department of Otolaryngology\u2013Head and Neck Surgery Virginia Commonwealth University School of Medicine Richmond Virginia U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Tang","sequence":"additional","affiliation":[{"name":"Department of Radiology Virginia Commonwealth University School of Medicine Richmond Virginia U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian","family":"Suddarth","sequence":"additional","affiliation":[{"name":"Department of Radiology Virginia Commonwealth University School of Medicine Richmond Virginia U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammed","family":"Mamdani","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology\u2013Head and Neck Surgery Virginia Commonwealth University School of Medicine Richmond Virginia U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,4,11]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otc.2012.06.002"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.3310\/hta13180"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3181d279a3"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.3171\/2012.7.FOCUS12186"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00701-007-1179-0"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e3181f22660"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/00129492-200606000-00018"},{"key":"e_1_2_7_9_1","first-page":"E1","article-title":"Acoustic neuroma: what the evidence says about evaluation and treatment","volume":"60","author":"McDonald R","year":"2011","journal-title":"J Fam Pract"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.73.867.10817038"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/lary.21799"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/MLG.0b013e3181373876"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.09.2520"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1754-9485.2011.02249.x"},{"key":"e_1_2_7_15_1","first-page":"985","article-title":"Diagnostic accuracy of the constructive interference in steady state sequence alone for follow\u2010up imaging of vestibular schwannomas","volume":"30","author":"Ozgen B","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"e_1_2_7_16_1","doi-asserted-by":"crossref","first-page":"90","DOI":"10.4103\/0971-3026.82283","article-title":"Applications of 3D CISS sequence for problem solving in neuroimaging","volume":"21","author":"Hingwala D","year":"2011","journal-title":"Indian J Radiol Imaging"},{"key":"e_1_2_7_17_1","doi-asserted-by":"crossref","DOI":"10.1093\/oso\/9780198529446.001.0001","volume-title":"Methods for Economic Evaluation of Health Care Programmes","author":"Drummond MF","year":"2005"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/001316447303300309"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/lary.23943"},{"key":"e_1_2_7_20_1","first-page":"47","article-title":"Constructive interference in steady state\u20103DFT MR imaging of the inner ear and cerebellopontine angle","volume":"14","author":"Casselman JW","year":"1993","journal-title":"AJR Am J Roentgenol"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880030304"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1007\/s002340050474"},{"key":"e_1_2_7_23_1","first-page":"209","article-title":"Evaluation of the necessity of contrast in the follow\u2010up MRI of schwannomas","volume":"17","author":"Bayraktaroglu S","year":"2011","journal-title":"Diagn Interv Radiol"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.anl.2010.12.011"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-0709(99)90002-9"},{"key":"e_1_2_7_26_1","first-page":"1219","article-title":"Detection of acoustic schwannoma: use of constructive interference in the steady state three\u2010dimensional MR","volume":"17","author":"Stuckey SL","year":"1996","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-004-2579-7"},{"key":"e_1_2_7_28_1","first-page":"1211","article-title":"T2\u2010weighted MR characteristics of internal auditory canal masses","volume":"17","author":"Fukui MB","year":"1996","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1258\/0022215011906920"},{"key":"e_1_2_7_30_1","first-page":"1226","article-title":"Cost\u2010effective screening for acoustic neuroma with unenhanced MR: a clinician's perspective","volume":"17","author":"Jackler RK","year":"1996","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1080\/02688699550041133"},{"key":"e_1_2_7_32_1","first-page":"1205","article-title":"Low\u2010cost high\u2010resolution fast spin\u2010echo MR of acoustic schwannoma: an alternative to enhanced conventional spin\u2010echo MR?","volume":"17","author":"Allen RW","year":"1996","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/lary.24871"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-009-0529-4"},{"key":"e_1_2_7_35_1","first-page":"6855","article-title":"[Size of acoustic neurinomas assessed by CT and magnetic resonance scanning]","volume":"157","author":"Fiirgaard B","year":"1995","journal-title":"Ugeskr Laeger"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0194-59989570138-9"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000000459"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-4486.2010.02099.x"},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.2554"},{"key":"e_1_2_7_40_1","unstructured":"American College of Radiology Committee on Drugs and Contrast Media.ACR Manual on Contrast Media Version 9. Available at:http:\/\/www.acr.org\/\u223c\/media\/ACR\/Documents\/PDF\/QualitySafety\/Resources\/ContrastManual\/2013_Contrast_Media.pdf. Accessed Janruary 24 2014."},{"key":"e_1_2_7_41_1","doi-asserted-by":"publisher","DOI":"10.1093\/ndt\/gfk062"},{"key":"e_1_2_7_42_1","doi-asserted-by":"publisher","DOI":"10.1681\/ASN.2006060601"},{"key":"e_1_2_7_43_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-139X.2007.00401.x"},{"key":"e_1_2_7_44_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2011.08.013"},{"key":"e_1_2_7_45_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.10.4885"},{"key":"e_1_2_7_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0194-5998(98)70080-4"},{"key":"e_1_2_7_47_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0194-59989670286-3"},{"key":"e_1_2_7_48_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2015142690"},{"key":"e_1_2_7_49_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.15150025"},{"key":"e_1_2_7_50_1","unstructured":"Centers for Medicare & Medicaid Services.National Health Expenditures 2015 Highlights. Available at:http:\/\/www.cms.gov\/Research\u2010Statistics\u2010Data\u2010and\u2010Systems\/Statistics\u2010Trends\u2010and\u2010Reports\/NationalHealthExpendData\/Downloads\/highlights.pdf. Accessed May 29 2015."},{"key":"e_1_2_7_51_1","doi-asserted-by":"crossref","first-page":"E1","DOI":"10.3171\/2014.3.FOCUS1447","article-title":"Variations in cost calculations in spine surgery cost\u2010effectiveness research","volume":"36","author":"Alvin MD","year":"2014","journal-title":"Neurosurg Focus"},{"key":"e_1_2_7_52_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1996.03540150055031"},{"key":"e_1_2_7_53_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016489.2014.890293"},{"key":"e_1_2_7_54_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otc.2011.12.008"},{"key":"e_1_2_7_55_1","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.131.3.241"},{"key":"e_1_2_7_56_1","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.1970.00770040187003"},{"key":"e_1_2_7_57_1","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.130.2.216"},{"key":"e_1_2_7_58_1","doi-asserted-by":"publisher","DOI":"10.1177\/019459989010300305"},{"key":"e_1_2_7_59_1","doi-asserted-by":"publisher","DOI":"10.1177\/014107689308600810"},{"key":"e_1_2_7_60_1","doi-asserted-by":"publisher","DOI":"10.1017\/S0022215100135935"},{"key":"e_1_2_7_61_1","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.126.8.963"},{"key":"e_1_2_7_62_1","doi-asserted-by":"publisher","DOI":"10.2310\/7070.2003.13947"},{"key":"e_1_2_7_63_1","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/S0194-5998(97)70229-8","article-title":"Cost\u2010effective evaluation of asymmetric sensorineural hearing loss with focused magnetic resonance imaging","volume":"116","author":"Carrier DA","journal-title":"Otolaryngol Head Neck Surg"},{"key":"e_1_2_7_64_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0194-59980300358-9"},{"key":"e_1_2_7_65_1","doi-asserted-by":"publisher","DOI":"10.1080\/00016480500504184"},{"key":"e_1_2_7_66_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.13.10610"}],"container-title":["The Laryngoscope"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Flary.26589","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/lary.26589","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,23]],"date-time":"2024-06-23T14:25:55Z","timestamp":1719152755000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/lary.26589"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4,11]]},"references-count":65,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,1]]}},"alternative-id":["10.1002\/lary.26589"],"URL":"https:\/\/doi.org\/10.1002\/lary.26589","archive":["Portico"],"relation":{},"ISSN":["0023-852X","1531-4995"],"issn-type":[{"value":"0023-852X","type":"print"},{"value":"1531-4995","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,4,11]]}}}