{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T19:41:33Z","timestamp":1757706093953},"reference-count":32,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2002,3,1]],"date-time":"2002-03-01T00:00:00Z","timestamp":1014940800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Lasers Surg Med"],"published-print":{"date-parts":[[2002,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background and Objective<\/jats:title><jats:p>To evaluate the potentials of a 1310\u2010nm optical coherence tomography (OCT) system to penetrate the highly backscattering sclera in enucleated human eyes and provide visualization of intraocular structures by transscleral imaging.<\/jats:p><\/jats:sec><jats:sec><jats:title>Study Design\/Materials and Methods<\/jats:title><jats:p>OCT\u2010images were generated by an experimental prototype (Medical Laser Center, L\u00fcbeck, Germany) using a superluminescence diode with a wavelength of 1310 nm. OCT\u2010images were taken from two enucleated human eyes using 100\u2013200 axial scans with 60 Hz line scan frequency and compared to subsequent histologic sections.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Transscleral OCT allowed penetration of the sclera and the anterior chamber angle could be completely identified. Some change within the anterior eye segment could be demonstrated with high accuracy. Additionally, limited demonstration of the ciliary body region was achieved. Due to limited signal intensity no detailed imaging of the pars plana and pars plicata region was possible. However, more posterior measurements allowed transscleral visualization of a retinal detachment.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>OCT using lightsources with a wavelength longer than that used in conventional OCT provides a promising imaging technique at high resolution allowing transscleral imaging of the anterior eye segment. Lasers Surg. Med. 30:209\u2010215, 2002. \u00a9 2002 Wiley\u2010Liss, Inc.<\/jats:p><\/jats:sec>","DOI":"10.1002\/lsm.10031","type":"journal-article","created":{"date-parts":[[2002,8,25]],"date-time":"2002-08-25T23:09:26Z","timestamp":1030316966000},"page":"209-215","source":"Crossref","is-referenced-by-count":7,"title":["Transscleral optical coherence tomography\u2014An experimental study in ex\u2010vivo human eyes*\u2020"],"prefix":"10.1002","volume":"30","author":[{"given":"Hans","family":"Hoerauf","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00f6rg","family":"Winkler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Scholz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher","family":"Wirbelauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roswitha S.","family":"Gordes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Koch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ralf","family":"Engelhardt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Horst","family":"Laqua","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Reginald","family":"Birngruber","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2002,3]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(98)93601-6"},{"key":"e_1_2_1_3_2","volume-title":"Optical coherence tomography of ocular diseases","author":"Puliafito CA","year":"1996"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(96)30568-X"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1995.01100050054031"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)71035-9"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(96)30377-1"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1007\/s004170050002"},{"key":"e_1_2_1_9_2","doi-asserted-by":"crossref","first-page":"218","DOI":"10.3928\/1542-8877-20000501-11","article-title":"First experimental and clinical results with transscleral optical coherence tomography","volume":"31","author":"Hoerauf H","year":"2000","journal-title":"Ophthalmic Surg Lasers"},{"key":"e_1_2_1_10_2","first-page":"786","article-title":"First experimental and clinical results of transscleral OCT","volume":"41","author":"Hoerauf H","year":"2000","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1994.01090240090031"},{"key":"e_1_2_1_12_2","first-page":"675","article-title":"Real\u2010time optical coherence tomography of the anterior segment","volume":"41","author":"Izatt JA","year":"2000","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s003470050143"},{"key":"e_1_2_1_14_2","unstructured":"WirbelauerC HoeraufH ScholzC EngelhardtR BastianGO BirngruberR LaquaH.1999.Non\u2010contact corneal pachymetry with optical coherence tomography. Annual Meeting of the American Academy of Ophthalmolgy. Final Program. p154."},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(00)00602-4"},{"key":"e_1_2_1_16_2","first-page":"337","article-title":"Comparison of the configuration of the human anterior chamber angle, as determined by the spaeth gonioscopic grading system and ultrasound biomicroscopy","volume":"93","author":"Spaeth GL","year":"1995","journal-title":"Trans Am Ophthalmol Soc"},{"key":"e_1_2_1_17_2","first-page":"73","volume-title":"Clinical gonioscopy. A text and stereoscopic atlas","author":"Becker SC","year":"1972"},{"key":"e_1_2_1_18_2","first-page":"2970","volume-title":"Lasers in surgery: Advanced characterization, therapeutics and systems","author":"Welzel J","year":"1997"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0190-9622(97)70072-0"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1038\/nm0995-970"},{"key":"e_1_2_1_21_2","first-page":"2395","volume-title":"Lasers in surgery: advanced characterization, therapeutics, and system V","author":"Di Carlo CD","year":"1995"},{"key":"e_1_2_1_22_2","first-page":"1","volume-title":"Biomedical foundations of ophthalomolgy","author":"Torcynski E","year":"1988"},{"key":"e_1_2_1_23_2","first-page":"15","volume-title":"Handbook of optics","author":"Tyler JE","year":"1978"},{"key":"e_1_2_1_24_2","unstructured":"SeeEF.1978.Maker. Transmission and absorption coefficients for ocular media of the rhesus monkey. USAF School of Aerospace Medicine Brooks AFB."},{"key":"e_1_2_1_25_2","first-page":"650","volume-title":"International Congress Series No. 450, Twenty\u2010third Concilium Ophthalmologicum","author":"Gabel VP","year":"1978"},{"key":"e_1_2_1_26_2","first-page":"289","volume-title":"The eye","author":"Maurice DM","year":"1962"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1002\/lsm.1900110404"},{"key":"e_1_2_1_28_2","unstructured":"K\u00f6llR.Experimentelle Untersuchungen zur Sklerostomie mittels Nd: Yag Laser. Dissertation thesis Ludwig Maximilians University Munich 1990."},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.1007\/s003470050393"},{"key":"e_1_2_1_30_2","first-page":"469","article-title":"Ultrasound biomicroscopy of the anterior segment","volume":"67","author":"Liebmann JM","year":"1986","journal-title":"J Am Optom Assoc"},{"key":"e_1_2_1_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(91)32298-X"},{"key":"e_1_2_1_32_2","first-page":"115","article-title":"A comparison of ophthalmic fiber optic microfocussing systems","volume":"2","author":"Rol P","year":"1988","journal-title":"Lasers Light Ophthalmol"},{"key":"e_1_2_1_33_2","doi-asserted-by":"publisher","DOI":"10.1364\/AO.10.000459"}],"container-title":["Lasers in Surgery and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Flsm.10031","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/lsm.10031","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T14:55:23Z","timestamp":1700319323000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/lsm.10031"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,3]]},"references-count":32,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2002,3]]}},"alternative-id":["10.1002\/lsm.10031"],"URL":"https:\/\/doi.org\/10.1002\/lsm.10031","archive":["Portico"],"relation":{},"ISSN":["0196-8092","1096-9101"],"issn-type":[{"value":"0196-8092","type":"print"},{"value":"1096-9101","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,3]]}}}