{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T23:04:03Z","timestamp":1794006243089,"version":"4.8.0"},"reference-count":37,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2013,2,18]],"date-time":"2013-02-18T00:00:00Z","timestamp":1361145600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Microsurgery"],"published-print":{"date-parts":[[2013,7]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Ultrasound (US) has been used in the management of carpal tunnel syndrome since the 1980s. The first report of US\u2010guided carpal tunnel release (CTR) was published in 1997, with cadaver and clinical reports confirming the safe navigation of surgical tools with US for division of the transverse carpal ligament. The MANOS CTR device was recently reported as a minimally invasive tool for CTR, and may be well suited for use with US guidance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients and methods<\/jats:title>\n                    <jats:p>The authors report three cases of US\u2010guided CTR using the MANOS CTR device. The MANOS device was inserted in a blunt configuration into the safe zone, and the cutting surface was deployed with a thumb\u2010activated trigger that simultaneously ejected a sharp through the palm. The transverse carpal ligament was divided safely and confirmed with US.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>US allowed for clear identification of the median nerve, safe zones, transverse carpal ligament, and the MANOS CTR device in relation to all pertinent structures of the carpal tunnel. Complete division of the transverse carpal ligament was confirmed in all three cases. There were no median nerve, vessel, tendon injuries, or chronic regional pain syndrome in any of the three cases.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>US\u2010guided CTR with the MANOS CTR device appears to be a safe technique and successful in confirming complete release. \u00a9 2013 Wiley Periodicals, Inc. Microsurgery 33:362\u2013366, 2013.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/micr.22092","type":"journal-article","created":{"date-parts":[[2013,2,18]],"date-time":"2013-02-18T17:38:42Z","timestamp":1361209122000},"page":"362-366","source":"Crossref","is-referenced-by-count":39,"title":["Ultrasound\u2010guided carpal tunnel release using the manos CTR system"],"prefix":"10.1002","volume":"33","author":[{"given":"Gregory","family":"Buncke","sequence":"first","affiliation":[{"name":"Department of Plastic Surgery California Pacific Medical Center San Francisco CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruce","family":"Mccormack","sequence":"additional","affiliation":[{"name":"Clinical Faculty Department of Neurosurgery University of California San Francisco Medical Center San Francisco California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marko","family":"Bodor","sequence":"additional","affiliation":[{"name":"Department of Neurological Surgery University of California San Francisco CA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2013,2,18]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(05)80001-2"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1093\/rheumatology\/33.12.1169"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1177\/1753193408090104"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2474-10-144"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2009.04.034"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjps.2007.10.006"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2005.02.007"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.2105\/AJPH.81.2.189"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(05)80291-9"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2006.07.018"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(94)90088-4"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(09)91044-9"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199309000-00002"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(05)80109-4"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1142\/S0218810411005564"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4419-1681-5_23"},{"key":"e_1_2_6_18_1","first-page":"363","article-title":"Ultrasound\u2010 or nerve stimulation\u2010guided wrist blocks for carpal tunnel release: A randomized prospective comparative study","volume":"33","author":"Macaire P","year":"2008","journal-title":"Reg Anesth Pain Med"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.sap.0000168281.77528.02"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbspin.2010.12.006"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(97)80081-0"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2009.12.016"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/micr.21987"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/micr.20959"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(94)90234-8"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1177\/1753193408097322"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20090818-14"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2011.12.033"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(94)90039-6"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(94)90070-1"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-001-0117-8"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.23389"},{"key":"e_1_2_6_33_1","first-page":"3","article-title":"The diagnostic value of ultrasonography in patients with electrophysiologically confirmed carpal tunnel syndrome","volume":"49","author":"Ashraf AR","year":"2009","journal-title":"Electromyogr Clin Neurophysiol"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0033-8389(05)70132-9"},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.crad.2007.01.029"},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.20252"},{"key":"e_1_2_6_37_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.01653"},{"key":"e_1_2_6_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(98)80165-2"}],"container-title":["Microsurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmicr.22092","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/micr.22092","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,4]],"date-time":"2023-10-04T02:47:42Z","timestamp":1696387662000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/micr.22092"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,2,18]]},"references-count":37,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2013,7]]}},"alternative-id":["10.1002\/micr.22092"],"URL":"https:\/\/doi.org\/10.1002\/micr.22092","archive":["Portico"],"relation":{},"ISSN":["0738-1085","1098-2752"],"issn-type":[{"value":"0738-1085","type":"print"},{"value":"1098-2752","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,2,18]]}}}