{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,8]],"date-time":"2026-02-08T12:14:21Z","timestamp":1770552861046,"version":"3.49.0"},"reference-count":41,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2017,2,16]],"date-time":"2017-02-16T00:00:00Z","timestamp":1487203200000},"content-version":"vor","delay-in-days":15,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/100000070","name":"National Institute of Biomedical Imaging and Bioengineering","doi-asserted-by":"publisher","award":["R01 EB001457"],"award-info":[{"award-number":["R01 EB001457"]}],"id":[{"id":"10.13039\/100000070","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000050","name":"National Heart, Lung, and Blood Institute","doi-asserted-by":"publisher","award":["R01 HL122484"],"award-info":[{"award-number":["R01 HL122484"]}],"id":[{"id":"10.13039\/100000050","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2017,2]]},"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>Amplitude\u2010based respiratory gating is known to capture the extent of respiratory motion (<jats:styled-content style=\"fixed-case\">RM<\/jats:styled-content>) accurately but results in residual motion in the presence of respiratory hysteresis. In our previous study, we proposed and developed a novel approach to account for respiratory hysteresis by applying the Bouc\u2013Wen (<jats:styled-content style=\"fixed-case\">BW<\/jats:styled-content>) model of hysteresis to external surrogate signals of anterior\/posterior motion of the abdomen and chest with respiration. In this work, using simulated and clinical <jats:styled-content style=\"fixed-case\">SPECT<\/jats:styled-content> myocardial perfusion imaging (<jats:styled-content style=\"fixed-case\">MPI<\/jats:styled-content>) studies, we investigate the effects of respiratory hysteresis and evaluate the benefit of correcting it using the proposed <jats:styled-content style=\"fixed-case\">BW<\/jats:styled-content> model in comparison with the abdomen signal typically employed clinically.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The <jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content> navigator data acquired in free\u2010breathing human volunteers were used in the specially modified 4D <jats:styled-content style=\"fixed-case\">NCAT<\/jats:styled-content> phantoms to allow simulating three types of respiratory patterns: monotonic, mild hysteresis, and strong hysteresis with normal myocardial uptake, and perfusion defects in the anterior, lateral, inferior, and septal locations of the mid\u2010ventricular wall. Clinical scans were performed using a Tc\u201099m sestamibi <jats:styled-content style=\"fixed-case\">MPI<\/jats:styled-content> protocol while recording respiratory signals from thoracic and abdomen regions using a visual tracking system (<jats:styled-content style=\"fixed-case\">VTS<\/jats:styled-content>). The performance of the correction using the respiratory signals was assessed through polar map analysis in phantom and 10 clinical studies selected on the basis of having substantial <jats:styled-content style=\"fixed-case\">RM<\/jats:styled-content>.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>In phantom studies, simulations illustrating normal myocardial uptake showed significant differences (<jats:italic>P\u00a0<\/jats:italic>&lt;\u00a00.001) in the uniformity of the polar maps between the <jats:styled-content style=\"fixed-case\">RM<\/jats:styled-content> uncorrected and corrected. No significant differences were seen in the polar map uniformity across the <jats:styled-content style=\"fixed-case\">RM<\/jats:styled-content> corrections. Studies simulating perfusion defects showed significantly decreased errors (<jats:italic>P\u00a0<\/jats:italic>&lt;\u00a00.001) in defect severity and extent for the <jats:styled-content style=\"fixed-case\">RM<\/jats:styled-content> corrected compared to the uncorrected. Only for the strong hysteretic pattern, there was a significant difference (<jats:italic>P\u00a0<\/jats:italic>&lt;\u00a00.001) among the <jats:styled-content style=\"fixed-case\">RM<\/jats:styled-content> corrections. The errors in defect severity and extent for the <jats:styled-content style=\"fixed-case\">RM<\/jats:styled-content> correction using abdomen signal were significantly higher compared to that of the <jats:styled-content style=\"fixed-case\">BW<\/jats:styled-content> (severity\u00a0=\u00a0\u22124.0%, <jats:italic>P\u00a0<\/jats:italic>&lt;\u00a00.001; extent\u00a0=\u00a0\u221265.4%, <jats:italic>P\u00a0<\/jats:italic>&lt;\u00a00.01) and chest (severity\u00a0=\u00a0\u22124.1%, <jats:italic>P\u00a0<\/jats:italic>&lt;\u00a00.001; extent\u00a0=\u00a0\u221252.5%, <jats:italic>P\u00a0<\/jats:italic>&lt;\u00a00.01) signals. In clinical studies, the quantitative analysis of the polar maps demonstrated qualitative and quantitative but not statistically significant differences (<jats:italic>P\u00a0<\/jats:italic>=\u00a00.73) between the correction methods that used the <jats:styled-content style=\"fixed-case\">BW<\/jats:styled-content> signal and the abdominal signal.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>This study shows that hysteresis in respiration affects the extent of residual motion left in the <jats:styled-content style=\"fixed-case\">RM<\/jats:styled-content>\u2010binned data, which can impact wall uniformity and the visualization of defects. Thus, there appears to be the potential for improved accuracy in reconstruction in the presence of hysteretic <jats:styled-content style=\"fixed-case\">RM<\/jats:styled-content> with the <jats:styled-content style=\"fixed-case\">BW<\/jats:styled-content> model method providing a possible step in the direction of improvement.<\/jats:p><\/jats:sec>","DOI":"10.1002\/mp.12072","type":"journal-article","created":{"date-parts":[[2016,12,29]],"date-time":"2016-12-29T14:23:20Z","timestamp":1483021400000},"page":"437-450","source":"Crossref","is-referenced-by-count":11,"title":["Correction of hysteretic respiratory motion in <scp>SPECT<\/scp> myocardial perfusion imaging: Simulation and patient studies"],"prefix":"10.1002","volume":"44","author":[{"given":"Paul K. R.","family":"Dasari","sequence":"first","affiliation":[{"name":"Department of Radiology Division of Nuclear Medicine University of Maryland School of Medicine Baltimore MD 21201 USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arda","family":"K\u00f6nik","sequence":"additional","affiliation":[{"name":"Department of Radiology Division of Nuclear Medicine University of Massachusetts Medical School Worcester MA 01655 USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P. Hendrik","family":"Pretorius","sequence":"additional","affiliation":[{"name":"Department of Radiology Division of Nuclear Medicine University of Massachusetts Medical School Worcester MA 01655 USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karen L.","family":"Johnson","sequence":"additional","affiliation":[{"name":"Department of Radiology Division of Nuclear Medicine University of Massachusetts Medical School Worcester MA 01655 USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William P.","family":"Segars","sequence":"additional","affiliation":[{"name":"Department of Radiology Carl E. Ravin Advanced Imaging Laboratory Duke University Medical Center Durham NC 27705 USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammed S.","family":"Shazeeb","sequence":"additional","affiliation":[{"name":"Department of Radiology Division of Nuclear Medicine University of Massachusetts Medical School Worcester MA 01655 USA"},{"name":"Department of Biomedical Engineering Worcester Polytechnic Institute Worcester MA 01609 USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael A.","family":"King","sequence":"additional","affiliation":[{"name":"Department of Radiology Division of Nuclear Medicine University of Massachusetts Medical School Worcester MA 01655 USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,2,16]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.1576230"},{"key":"e_1_2_9_3_1","first-page":"1357","article-title":"Acquisition and automated 3\u2010D segmentation of respiratory\/cardiac\u2010gated PET transmission images","volume":"1997","author":"Reutter BW","year":"1996","journal-title":"IEEE Nucl Sci Symp Conf Rec"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12350-009-9148-z"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2825616"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2203010132"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1109\/TNS.2013.2294829"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24502"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2219772"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2748104"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/52\/12\/012"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2007.09.013"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3517836"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2005.03.070"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/53\/11\/011"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-008-0868-0"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-010-1533-y"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1186\/2191-219X-3-29"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4930251"},{"key":"e_1_2_9_20_1","first-page":"687","article-title":"Quantitative assessment of motion artifacts and validation of a new motion\u2010correction program for myocardial perfusion SPECT","volume":"42","author":"Matsumoto N","year":"2001","journal-title":"J Nucl Med"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1109\/TNS.2002.803678"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4895845"},{"key":"e_1_2_9_23_1","first-page":"16","article-title":"Mod\u00e8le math\u00e9matique d'hyst\u00e9r\u00e9sis","volume":"24","author":"Bouc R","year":"1971","journal-title":"Acustica"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1061\/JMCEA3.0002106"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1109\/TNS.2008.2007739"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12149-009-0277-x"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/TNS.2009.2015446"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4788669"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.106.037390"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.173.1.2781017"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3117592"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11538-012-9733-1"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1109\/TNS.2002.1039548"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2002.804427"},{"key":"e_1_2_9_35_1","first-page":"181","volume-title":"Proc Fully\u20103D Image Reconstruction Radiol Nucl Med","author":"Pan T","year":"1995"},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1109\/42.363108"},{"key":"e_1_2_9_37_1","first-page":"1725","article-title":"Human\u2010observer receiver\u2010operating\u2010characteristic evaluation of attenuation, scatter, and resolution compensation strategies for 99mTc myocardial perfusion imaging","volume":"44","author":"Narayanan MV","year":"2003","journal-title":"J Nucl Med"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12350-013-9791-2"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.1148\/rg.317115090"},{"key":"e_1_2_9_40_1","first-page":"3","article-title":"Automated quantification of myocardial ischemia and wall motion defects by use of cardiac SPECT polar mapping and 4\u2010dimensional surface rendering","volume":"34","author":"Lin GS","year":"2006","journal-title":"J Nucl Med Tech"},{"key":"e_1_2_9_41_1","volume-title":"Cardiac SPECT Imaging","author":"Depuey EGM","year":"2001"},{"key":"e_1_2_9_42_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2016.2576899"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmp.12072","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.12072","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T10:35:28Z","timestamp":1694774128000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/mp.12072"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2]]},"references-count":41,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017,2]]}},"alternative-id":["10.1002\/mp.12072"],"URL":"https:\/\/doi.org\/10.1002\/mp.12072","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,2]]}}}