{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T23:44:57Z","timestamp":1790293497169,"version":"4.1.0"},"reference-count":52,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2019,12,30]],"date-time":"2019-12-30T00:00:00Z","timestamp":1577664000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","award":["241018"],"award-info":[{"award-number":["241018"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2020,3]]},"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>Intensity modulated brachytherapy (IMBT) is a novel high dose rate brachytherapy (HDR BT) technique which incorporates static or dynamic shielding to increase tumor coverage and\/or spare healthy tissues. The purpose of this study is to present a novel delivery system (AIM\u2010Brachy) design that can enable dynamic\u2010shield IMBT for prostate cancer.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The AIM\u2010Brachy system dynamically controls the rotation of platinum shields, placed within interstitial catheters, which partially collimate the radiation emitted from an <jats:sup>169<\/jats:sup>Yb source. Conventional HDR BT (10\u00a0Ci <jats:sup>192<\/jats:sup>Ir) and IMBT (18\u00a0Ci <jats:sup>169<\/jats:sup>Yb) plans were generated for 12 patients using an in\u2010house column generation\u2010based optimizer, coupled to a Geant4\u2010based dose calculation engine, RapidBrachyMC. Treatment plans were normalized to match the same PTV <jats:italic>D<jats:sub>90<\/jats:sub><\/jats:italic> coverage as the clinical plan. Intershield attenuation effects were taken into account. A sensitivity analysis was performed to evaluate the dosimetric impact of systematic longitudinal source positioning errors (<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0001.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0001\"\/>1\u00a0mm, <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0002.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0002\"\/>2\u00a0mm, and <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0003.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0003\"\/>3\u00a0mm) and rotational errors (<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0004.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0004\"\/>5<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0005.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0005\"\/>, <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0006.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0006\"\/>10<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0007.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0007\"\/> and <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0008.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0008\"\/>15<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0009.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0009\"\/>) on clinically relevant parameters (PTV <jats:italic>D<jats:sub>90<\/jats:sub><\/jats:italic> and urethra <jats:italic>D<jats:sub>10<\/jats:sub><\/jats:italic>).<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The platinum shield reduced the dose rate on the shielded side at 1\u00a0cm to 18.1% of the dose rate on the unshielded side. For equal PTV <jats:italic>D<jats:sub>90<\/jats:sub><\/jats:italic> coverage, the urethral <jats:italic>D<jats:sub>10<\/jats:sub><\/jats:italic> was reduced by 13.3%\u00a0<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0010.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0010\"\/>\u00a04.7%, without change to other plan quality indices (PTV <jats:italic>V<jats:sub>100<\/jats:sub><\/jats:italic>, <jats:italic>V<jats:sub>150,<\/jats:sub> V<jats:sub>200<\/jats:sub><\/jats:italic>, bladder <jats:italic>V<jats:sub>75<\/jats:sub><\/jats:italic>, rectum <jats:italic>V<jats:sub>75<\/jats:sub><\/jats:italic>, HI, COIN). Delivery times for HDR BT and IMBT were 9.2\u00a0\u00b1\u00a01.6\u00a0min and 18.6\u00a0\u00b1\u00a04.0\u00a0min, respectively. In general, the PTV <jats:italic>D<jats:sub>90<\/jats:sub><\/jats:italic> was more sensitive to source positioning errors than rotational errors, while the urethral <jats:italic>D<jats:sub>10<\/jats:sub><\/jats:italic> was more sensitive to rotational errors than source positioning errors. For a typical range of positioning errors (<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0011.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0011\"\/>1\u00a0mm, <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0012.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0012\"\/>5<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp13959-math-0013.png\" xlink:title=\"urn:x-wiley:00942405:media:mp13959:mp13959-math-0013\"\/>), the overall tolerance was &lt;2%.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The AIM\u2010Brachy system was proposed to deliver dynamic\u2010shield IMBT for prostate cancer with the potential to create a low dose tunnel within the urethra. The urethra\u2010sparing properties are desirable to minimize the occurrence and severity of urethral strictures or, alternatively, to provide a method for dose escalation.<\/jats:p><\/jats:sec>","DOI":"10.1002\/mp.13959","type":"journal-article","created":{"date-parts":[[2019,12,12]],"date-time":"2019-12-12T08:41:44Z","timestamp":1576140104000},"page":"859-868","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["A novel <sup>169<\/sup>Yb\u2010based dynamic\u2010shield intensity modulated brachytherapy delivery system for prostate cancer"],"prefix":"10.1002","volume":"47","author":[{"given":"Gabriel","family":"Famulari","sequence":"first","affiliation":[{"name":"Medical Physics Unit McGill University Montr\u00e9al Qu\u00e9bec H4A 3J1 Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marie","family":"Duclos","sequence":"additional","affiliation":[{"name":"Department of Oncology McGill University Montr\u00e9al Qu\u00e9bec H4A 3J1 Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shirin A.","family":"Enger","sequence":"additional","affiliation":[{"name":"Medical Physics Unit McGill University Montr\u00e9al Qu\u00e9bec H4A 3J1 Canada"},{"name":"Department of Oncology McGill University Montr\u00e9al Qu\u00e9bec H4A 3J1 Canada"},{"name":"Research Institute of the McGill University Health Centre Montr\u00e9al Qu\u00e9bec H3H 2R9 Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2019,12,30]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.5114\/jcb.2014.45759"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.21037\/tau.2017.12.08"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.5114\/jcb.2012.29370"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2016.72.0466"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2012.01.007"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/bju.12514"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.brachy.2011.01.003"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2011.10.055"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2010.09.021"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2011.01.005"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.brachy.2009.04.007"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2008.11.006"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2009.08.048"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2010.04.046"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/47\/14\/309"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03178889"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3456598"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4870441"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2017.06.008"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2018.07.2015"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/58\/11\/3931"},{"key":"e_1_2_8_23_1","first-page":"6579","article-title":"Multihelix rotating shield brachytherapy for cervical cancer","volume":"72","author":"Dadkhah H","year":"2014","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2014.02.039"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2016.06.015"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12598"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4769416"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4816677"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/58\/4\/957"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.apradiso.2017.09.028"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.596813"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2147767"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3301607"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4812675"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12111"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13563"},{"key":"e_1_2_8_37_1","volume-title":"The Production of Ytterbium\u2010169 Radiography Sources in a High Flux Reactor","author":"Hetherington ELR","year":"1974"},{"key":"e_1_2_8_38_1","volume-title":"Manual for Reactor Produced Radioisotopes","author":"IAEA","year":"2003"},{"key":"e_1_2_8_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8140(16)31505-5"},{"key":"e_1_2_8_40_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aad97a"},{"key":"e_1_2_8_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-9002(03)01368-8"},{"key":"e_1_2_8_42_1","doi-asserted-by":"publisher","DOI":"10.1109\/TNS.2006.869826"},{"key":"e_1_2_8_43_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.596069"},{"key":"e_1_2_8_44_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4747264"},{"key":"e_1_2_8_45_1","volume-title":"Photon, electron, proton and neutron interaction data for body tissues","author":"ICRU Report 46","year":"1992"},{"key":"e_1_2_8_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2009.08.048"},{"key":"e_1_2_8_47_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.596152"},{"key":"e_1_2_8_48_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(97)00732-3"},{"key":"e_1_2_8_49_1","first-page":"125","article-title":"Co\u201060 versus Ir\u2010192 in HDR brachytherapy: Scientific and technological comparison","volume":"13","author":"Andr\u00e1ssy M","year":"2012","journal-title":"Rev Phys Med"},{"key":"e_1_2_8_50_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10717-018-0026-5"},{"key":"e_1_2_8_51_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-7-56"},{"key":"e_1_2_8_52_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.meddos.2009.01.005"},{"key":"e_1_2_8_53_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2017.09.040"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmp.13959","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.13959","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mp.13959","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.13959","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,6]],"date-time":"2023-09-06T23:13:26Z","timestamp":1694042006000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/mp.13959"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,30]]},"references-count":52,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,3]]}},"alternative-id":["10.1002\/mp.13959"],"URL":"https:\/\/doi.org\/10.1002\/mp.13959","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,30]]},"assertion":[{"value":"2019-08-30","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-12-06","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-12-30","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}