{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,24]],"date-time":"2025-08-24T01:31:36Z","timestamp":1755999096865,"version":"3.41.2"},"reference-count":43,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2022,12,29]],"date-time":"2022-12-29T00:00:00Z","timestamp":1672272000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["32227801"],"award-info":[{"award-number":["32227801"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2023,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>Computed tomography (CT) image\u2010based patient\u2010specific voxel\u2010based dosimetry has difficulties complementing missing tissues for organs located partially inside or completely outside the image volume. Previous studies constructed patient\u2010specific whole\u2010body models by rescaling reference phantoms or extending regional CT images with manually adjusted phantoms. This study proposes a methodology for automatic organ completion of regional CT images for CT dosimetry using a stitching approach.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Virtual clinical trials were performed by truncating whole\u2010body CT images to generate virtual clinical chest and abdominopelvic CT images. Corresponding anchor images for each patient were selected according to sex and similarity of the axial length and water equivalent diameter of the virtual regional CT images. Automatic image stitching was performed by transformation initialization and iteration, while the stitched CT images and organ atlas were used in GPU\u2010based Geant4 Monte Carlo simulations to generate a radiation dose map and absorbed organ dose. To evaluate the performance of the stitching model in radiation dosimetry, organ mass differences and Jaccard's coefficient of stitched and rescaled anchor images were calculated, and the radiation doses were compared among the corresponding values from the VirtualDose\u00ae, original whole\u2010body CT, stitching model, regional CT, registration\u2010based rescaling method, and WED\u2010based rescaling method.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The anatomical accuracy of stitched images was significantly improved. For organs partially inside the image volume, organ dose estimation from the stitching model could be more accurate than that reported in previous studies. The absolute differences in effective dose from the stitched images were 6.55% and 4.81% for chest and abdominopelvic CT scans, respectively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The proposed automatic stitching model partially complements organs inside or outside the CT scan range and provides more accurate anatomical representations for radiation dosimetry than traditional phantom rescaling methods.<\/jats:p><\/jats:sec>","DOI":"10.1002\/mp.16165","type":"journal-article","created":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T07:24:01Z","timestamp":1671261841000},"page":"2499-2509","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Automatic organ completion with image stitching for personalized radiation dosimetry in CT examinations"],"prefix":"10.1002","volume":"50","author":[{"given":"Lin","family":"Xin","sequence":"first","affiliation":[{"name":"Institute of Radiation Medicine Fudan University  Shanghai China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weihai","family":"Zhuo","sequence":"additional","affiliation":[{"name":"Institute of Radiation Medicine Fudan University  Shanghai China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haikuan","family":"Liu","sequence":"additional","affiliation":[{"name":"Institute of Radiation Medicine Fudan University  Shanghai China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tianwu","family":"Xie","sequence":"additional","affiliation":[{"name":"Institute of Radiation Medicine Fudan University  Shanghai China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2022,12,29]]},"reference":[{"volume-title":"Medical Radiation Exposure of Patients in the United States Report No.184","year":"2019","key":"e_1_2_8_2_1"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1001\/archinternmed.2009.427"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-019-06523-y"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2021.109871"},{"volume-title":"Communicating radiation risks in paediatric imaging: information to support healthcare discussions about benefit and risk","year":"2016","author":"World Health Organization","key":"e_1_2_8_6_1"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.icrp.2007.11.001"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa77ea"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3533897"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/52\/3\/001"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/50\/17\/005"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/52\/9\/017"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.598297"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/48\/16\/306"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.1796952"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/52\/12\/004"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3468099"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2009.12.043"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2011.06.072"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13781"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/nch002"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2011.06.047"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa63d0"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3544353"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/55\/13\/015"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/55\/13\/015"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10278-018-0119-2"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2009.09.040"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4883778"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3026593"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12502"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13471"},{"key":"e_1_2_8_33_1","first-page":"6982","article-title":"3D Slicer as a tool for interactive brain tumor segmentation","volume":"2011","author":"Kikinis R","year":"2011","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/45\/2\/314"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1109\/34.295913"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.3389\/fninf.2013.00045"},{"key":"e_1_2_8_37_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-017-5000-z"},{"key":"e_1_2_8_38_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/60\/13\/4987"},{"key":"e_1_2_8_39_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab0bd5"},{"key":"e_1_2_8_40_1","first-page":"1","article-title":"ICRP publication 103: the 2007 Recommendations of the International Commission on Radiological Protection","volume":"37","year":"2007","journal-title":"Ann ICRP"},{"key":"e_1_2_8_41_1","unstructured":"Bayer HealthCare.Radimetrics Enterprise Platform: Dose Management Solution.http:\/\/www.radiologysolutions.bayer.com\/products\/ct\/dosemanagement\/rep\/"},{"key":"e_1_2_8_42_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.14131"},{"key":"e_1_2_8_43_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/58\/21\/7661"},{"key":"e_1_2_8_44_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v14i4.4163"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.16165","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mp.16165","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.16165","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,1]],"date-time":"2025-08-01T10:24:18Z","timestamp":1754043858000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/mp.16165"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,29]]},"references-count":43,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,4]]}},"alternative-id":["10.1002\/mp.16165"],"URL":"https:\/\/doi.org\/10.1002\/mp.16165","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"type":"print","value":"0094-2405"},{"type":"electronic","value":"2473-4209"}],"subject":[],"published":{"date-parts":[[2022,12,29]]},"assertion":[{"value":"2021-12-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-12-05","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-12-29","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}