{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T05:12:00Z","timestamp":1782277920070,"version":"3.54.5"},"reference-count":22,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2024,1,26]],"date-time":"2024-01-26T00:00:00Z","timestamp":1706227200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2024,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Radiation exposure from interventional radiology (IR) could lead to potential risk of skin injury in patients. Several dose monitoring software like radiation dose monitor (RDM) were developed to estimate the patient skin dose (PSD) distribution in IR.<\/jats:p><\/jats:sec><jats:sec><jats:title>Purpose<\/jats:title><jats:p>This study benchmarked the accuracy of RDM software in estimating PSD as compared to GafChromic film baseline in\u2010vivo measurements on patients during cardiac, abdominal, and neurology IR procedures.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The prospective study conducted in four IR departments included 81 IR procedures (25 cardiac, 31 abdominal, and 25 neurology procedures) on three angiographic systems. PSD and field geometry were measured by placing GafChromic film under the patient's back. Statistical analyses were performed to compare the software estimation and film measurement results in terms of PSD and geometric accuracy.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Median values of measured\/calculated PSD were 1140\/1005, 591\/655.9, and 538\/409.7\u00a0mGy for neurology, cardiac, and abdominal procedures, respectively. For all angiographic systems, the median (InterQuartile Range, IQR) difference between calculated and measured PSD was \u221210.2% (\u221221.8%\u20135.7%) for neurology, \u22124.5% (\u221219.5%\u201315.5%) for cardiac, and \u221221.9% (\u221238.7%\u2013\u22123.6%) for abdominal IR procedures. These differences were not significant for all procedures (<jats:italic>p<\/jats:italic>\u00a0&gt;\u00a00.05). Discrepancies increased up to \u221282% in lower dose regions where the measurement uncertainties are higher. Regarding the geometric accuracy, RDM correctly reproduced the skin dose map and estimated PSD area dimensions closely matched those registered on films with a median (IQR) difference of 0\u00a0cm (\u22121\u20130.8\u00a0cm).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>RDM is proved to be a useful solution for the estimation of PSD and skin dose distribution during abdominal, cardiac and neurology IR procedures despite a geometry phantom which is not specific to the latter type of IR procedures.<\/jats:p><\/jats:sec>","DOI":"10.1002\/mp.16956","type":"journal-article","created":{"date-parts":[[2024,1,26]],"date-time":"2024-01-26T14:08:50Z","timestamp":1706278130000},"page":"3687-3697","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Clinical benchmarking of a commercial software for skin dose estimation in cardiac, abdominal, and neurology interventional procedures"],"prefix":"10.1002","volume":"51","author":[{"given":"Lama","family":"Hadid\u2010Beurrier","sequence":"first","affiliation":[{"name":"Medical Physics and Radiation Protection Department APHP Lariboisi\u00e8re University Hospital  Paris France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8154-4365","authenticated-orcid":false,"given":"Bouchra Habib","family":"Geryes","sequence":"additional","affiliation":[{"name":"Radiology Department APHP Necker\u2010Enfants Malades University Hospital  Paris France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonella","family":"Jean\u2010Pierre","sequence":"additional","affiliation":[{"name":"Medical Physics and Radiation Protection Department APHP Lariboisi\u00e8re University Hospital  Paris France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul\u2010Adrien","family":"Gaudin","sequence":"additional","affiliation":[{"name":"URC Lariboisi\u00e8re\u2010Saint Louis H\u00f4pital Fernand Widal  PARIS Cedex France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jo\u00eblle Ann","family":"Feghali","sequence":"additional","affiliation":[{"name":"Radiology Department APHP Bic\u00eatre Le Kremlin\u2010Bic\u00eatre  Paris France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,1,26]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0146\u20106453(01)00004\u20105"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2009.04.037"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncu314"},{"key":"e_1_2_9_5_1","first-page":"86683Z","volume-title":"Updates in the real\u2010time dose tracking system (DTS) to improve the accuracy in calculating the radiation dose to the patients skin during fluoroscopic procedures","author":"Rana VK","year":"2013"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncu181"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.28097"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2020.03.008"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13167"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2017.06.013"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13125"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2020.09.023"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2021.02.016"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v12i4.3670"},{"issue":"3","key":"e_1_2_9_15_1","article-title":"Adult mesh\u2010type reference computational phantoms. ICRP Publication 145","volume":"49","author":"ICRP","year":"2020","journal-title":"Ann ICRP"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncab146"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncw191"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4922132"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncw116"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncaa002"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330\u2010020\u201006877\u20108"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2022.05.002"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.14910"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.16956","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T15:24:54Z","timestamp":1755876294000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/mp.16956"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,26]]},"references-count":22,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024,5]]}},"alternative-id":["10.1002\/mp.16956"],"URL":"https:\/\/doi.org\/10.1002\/mp.16956","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,26]]},"assertion":[{"value":"2023-06-28","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-01-16","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-01-26","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}