{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T20:20:14Z","timestamp":1791836414967,"version":"4.3.4"},"reference-count":36,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2025,1,26]],"date-time":"2025-01-26T00:00:00Z","timestamp":1737849600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2025,1,26]],"date-time":"2025-01-26T00:00:00Z","timestamp":1737849600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Histotripsy is a non\u2010invasive, non\u2010ionizing, non\u2010thermal focused ultrasound technique. High amplitude short acoustic pulses converge to create high negative pressures that cavitate endogenous gas into a bubble cloud leading to mechanical tissue destruction. In the United States, histotripsy is approved to treat liver tumors under diagnostic ultrasound guidance but in initial clinical cases, some areas of the liver have not been treated due to bone or gas obstructing the acoustic window for targeting. To address this limitation in visualization, cone\u2010beam computed tomography (CBCT) guided histotripsy was developed to expand the number of tumors and patients that can be treated with histotripsy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The purpose of this work is to improve the accuracy of CBCT guided histotripsy by calibrating the therapeutic bubble cloud location relative to the histotripsy robot arm.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      The calibration correction involves creating a bubble cloud sized treatment (a few mm) in an agar\u2010based phantom consisting of 11 layers with alternating high and low x\u2010ray attenuation. The layers were spaced \u223c3\u00a0mm apart to allow visualization of mixing after mechanical disintegration from the histotripsy treatment. Bubble cloud treatments were localized using an automated algorithm that minimized a cost function based on the intensity difference within the treatment region on the pre\u2010 and post\u2010treatment CBCT. The actual treatment location can be compared to the theoretical bubble cloud location (focal point based on the CAD model of the transducer assembly) to calculate a 3D offset (\n                      <jats:italic>X<\/jats:italic>\n                      ,\n                      <jats:italic>Y<\/jats:italic>\n                      ,\n                      <jats:italic>Z<\/jats:italic>\n                      ), which is used as the calibration correction between the therapeutic bubble cloud location and the histotripsy robot arm. The phantom and algorithm were analyzed to determine parameters that maximized bubble cloud treatment detection (treatment duration, localization accuracy of the phantom, number of bubble clouds) and were tested on four different histotripsy transducers.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Bubble cloud locations were accurately identified with the automated algorithm from post\u2010treatment CBCT images of the multilayer agar phantom. Treating the phantom for 20\u00a0seconds was associated with the greatest change in CBCT intensity. The phantom and algorithm were able to localize changes in bubble cloud location with mean residual errors (MRE) between the measured and planned translations of 0.3\u00a0\u00b1\u00a00.3\u00a0mm in\n                      <jats:italic>X<\/jats:italic>\n                      , \u22120.2\u00a0\u00b1\u00a00.6\u00a0mm in\n                      <jats:italic>Y<\/jats:italic>\n                      , and 0.1\u00a0\u00b1\u00a01.0\u00a0mm in\n                      <jats:italic>Z<\/jats:italic>\n                      . A multi\u2010bubble cloud calibration approach with four adjacent bubble clouds provided a statistically significant lower mean absolute deviation (MAD) in measured 3D offset (0.1, 0.0 and 0.2\u00a0mm in\n                      <jats:italic>X<\/jats:italic>\n                      ,\n                      <jats:italic>Y<\/jats:italic>\n                      , and\n                      <jats:italic>Z<\/jats:italic>\n                      , respectively) compared to using a single bubble cloud (MAD of 0.2, 1.1 and 1.2\u00a0mm in\n                      <jats:italic>X<\/jats:italic>\n                      ,\n                      <jats:italic>Y<\/jats:italic>\n                      , and\n                      <jats:italic>Z<\/jats:italic>\n                      , respectively). The calibration correction method measured statistically significantly different 3D transducer offsets between the four histotripsy transducers.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Creating and analyzing four adjacent bubble clouds together produced more accurate and reproducible 3D offset measurements than analyzing individual bubble clouds. The presented histotripsy bubble cloud calibration correction method is automated, accurate, and can be easily integrated in the current histotripsy workflow to improve accuracy of CBCT guided histotripsy.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mp.17644","type":"journal-article","created":{"date-parts":[[2025,1,27]],"date-time":"2025-01-27T00:45:09Z","timestamp":1737938709000},"page":"3216-3227","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Calibration correction to improve registration during cone\u2010beam CT guided histotripsy"],"prefix":"10.1002","volume":"52","author":[{"given":"Katrina L.","family":"Falk","sequence":"first","affiliation":[{"name":"Department of Radiology University of Wisconsin\u2010Madison  Madison Wisconsin USA"},{"name":"Department of Biomedical Engineering University of Wisconsin\u2010Madison  Madison Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul F.","family":"Laeseke","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Wisconsin\u2010Madison  Madison Wisconsin USA"},{"name":"Department of Biomedical Engineering University of Wisconsin\u2010Madison  Madison Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Grace M.","family":"Minesinger","sequence":"additional","affiliation":[{"name":"Department of Medical Physics University of Wisconsin\u2010Madison  Madison Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Orhan G.","family":"Ozkan","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Wisconsin\u2010Madison  Madison Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael A.","family":"Speidel","sequence":"additional","affiliation":[{"name":"Department of Medical Physics University of Wisconsin\u2010Madison  Madison Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy J.","family":"Ziemlewicz","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Wisconsin\u2010Madison  Madison Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr.","given":"Fred T.","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Wisconsin\u2010Madison  Madison Wisconsin USA"},{"name":"Department of Urology University of Wisconsin\u2010Madison  Madison Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin G.","family":"Wagner","sequence":"additional","affiliation":[{"name":"Department of Radiology University of Wisconsin\u2010Madison  Madison Wisconsin USA"},{"name":"Department of Medical Physics University of Wisconsin\u2010Madison  Madison Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,1,26]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.COT.0000997472.28961.ec"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1109\/tuffc.2004.1304271"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.3109\/02656736.2015.1007538"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2016.05.018"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/59\/2\/253"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1146\/annurev\u2010bioeng\u2010073123\u2010022334"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1080\/02656736.2023.2233720"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/J.ULTRASMEDBIO.2012.09.004"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2018.10.035"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1109\/TUFFC.2014.6722618"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1080\/02656736.2021.1905189\/FORMAT\/EPUB"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2020.10.020"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1080\/02656736.2022.2112309"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270\u2010019\u201002215\u20108"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2018171544"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/59\/2\/253"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2013.02.005"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0301\u20105629(01)00389\u20101"},{"key":"e_1_2_9_20_1","doi-asserted-by":"crossref","unstructured":"KennedyJE Ter HaarGR CranstonD HospitalM and S. High intensity focused ultrasound: surgery of the future?doi:10.1259\/bjr\/17150274","DOI":"10.1259\/bjr\/17150274"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2361031249"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1080\/13651820701646222"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.RVI.0000092666.72261.6B"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.178.1.1780047"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2010.04.007"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270\u2010011\u20100241\u20108"},{"key":"e_1_2_9_27_1","volume-title":"Phase 1 study of safety and efficacy of hepatic histotripsy: preliminary results of first in man experience with robotically\u2010assisted sonic therapy","author":"Vidal Jove J","year":"2019"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270\u2010021\u201002914\u20101"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1109\/TUFFC.2016.2532504"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2022.3198600"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1117\/12.2654002"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2023.01.019"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.14329"},{"key":"e_1_2_9_34_1","unstructured":"Falk K.All images Created in BioRender. (2025)https:\/\/BioRender.com\/b00z086"},{"key":"e_1_2_9_35_1","doi-asserted-by":"publisher","DOI":"10.1093\/comjnl\/7.4.308"},{"key":"e_1_2_9_36_1","article-title":"An effective interactive medical image segmentation method using fast growcut","author":"Zhu L","year":"2014","journal-title":"MICCAI Work Interact Med Image Comput"},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.7150\/thno.6717"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.17644","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mp.17644","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.17644","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T10:01:18Z","timestamp":1777716078000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/mp.17644"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,26]]},"references-count":36,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025,5]]}},"alternative-id":["10.1002\/mp.17644"],"URL":"https:\/\/doi.org\/10.1002\/mp.17644","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,26]]},"assertion":[{"value":"2024-08-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-11","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-26","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}