{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T16:03:53Z","timestamp":1792080233736,"version":"4.4.0"},"reference-count":63,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2025,2,22]],"date-time":"2025-02-22T00:00:00Z","timestamp":1740182400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Inter\u2010fractional and intra\u2010fractional positioning and motion monitoring based on implanted fiducials through kilovoltage (kV) imaging is a cost\u2010effective approach to enhance intact prostate radiotherapy treatment accuracy. However, comprehensive studies for three\u2010dimensional (3D) position extraction and the corrective action threshold are lacking.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To develop and verify a fiducial motion monitoring system with 3D position information based on triggered kV images taken during treatment delivery, and to comprehensively evaluate the recommended thresholds for corrective action during\u00a0treatment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      An in\u2010house fiducial triangulation algorithm was developed to monitor fiducial positions using subsequent kV triggered images. The precision of fiducial triangulation and motion detection was validated on a pelvis phantom with four fiducial inserts. A retrospective study was conducted on prostate cancer patients who received either moderately hypofractionated radiotherapy (MHRT,\n                      <jats:italic>n<\/jats:italic>\n                      = 16) or stereotactic body radiotherapy (SBRT,\n                      <jats:italic>n<\/jats:italic>\n                      = 12), categorized by endo\u2010rectal balloon (ERB) use. Intra\u2010fractional positions relative to isocenter were computed, and these positions were analyzed in comparison to the original marker locations of the patient's treatment plan. A linear regression fit was used per fraction to determine correlation coefficients between motions in the left\u2013right (LR), superior\u2013inferior (SI), and anterior\u2013posterior (AP) directions. Average fraction time (AFT) of treatment was reported based on the observed average time spent on steps in the workflow and the percentage of fiducials caught outside of the current two\u2010dimensional (2D) tolerance threshold of 5 mm. The observed 3D offsets were used to estimate AFT for various 3D tolerance\u00a0thresholds.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Overall, our triangulation method proved to be very precise for static cases, where phantom measurements revealed a fiducial position triangulation precision of  mm for stationary targets, but had a spread of  mm for targets with 1 mm of motion. Employing triangulation, true motion exceeding 5 mm was detected above 4.0 mm in magnitude 90.9% of the time, a noticeable improvement in comparison to the 28%\u201365% successful detection rate reported by 2D projection methods. Most detection errors were attributed to depth disparity. Similar to other reports, correlation coefficients for intra\u2010fractional motion generally indicated no LR\/SI, no LR\/AP, and weak positive SI\/AP correlations for MHRT and SBRT patients. Offsets beyond a 3D tolerance threshold of 5 mm were observed at a rate of 4.25%\u20135.25%, while the 5 mm 2D out\u2010of\u2010tolerance catch\u2010rate was 1.6%. The AFT was 8.1\u20138.2 min using the 2D tolerance threshold of 5 mm. In comparison, the estimated AFT for the proposed 3D tolerance monitoring of offsets beyond 2\u20135 mm was slightly higher at 8.2\u201310.9 min due to the higher amount of out\u2010of\u2010tolerance instances for the higher precision intra\u2010fractional motion\u00a0management.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our study showcases a promising subsequent kV\u2010based triangulation method for intra\u2010fractional prostate motion monitoring. Acquiring 3D motion information results in higher out\u2010of\u2010tolerance catch\u2010rates particularly in the depth dimension of the kV images, which is perpendicular to the treatment beam. Failure to properly observe and catch these offsets would result in sub\u2010optimal conformality and accuracy of the dose\u00a0delivery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mp.17703","type":"journal-article","created":{"date-parts":[[2025,2,22]],"date-time":"2025-02-22T10:24:51Z","timestamp":1740219891000},"page":"4008-4022","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Subsequent kilovoltage imaging\u2010based fiducial triangulation for intra\u2010fractional prostate motion monitoring and correction"],"prefix":"10.1002","volume":"52","author":[{"given":"Gevork S.","family":"Gevorkyan","sequence":"first","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Quan","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riley C.","family":"Tegtmeier","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"},{"name":"Department of Radiation Oncology University of South Florida Morsani College of Medicine Tampa Florida USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diego Santos","family":"Toesca","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brady S.","family":"Laughlin","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara","family":"Bashir","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zachary J.","family":"Welchel","sequence":"additional","affiliation":[{"name":"Department of Medical Physics School of Medicine and Public Health University of Wisconsin \u2010 Madison Madison Wisconsin USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason M.","family":"Holmes","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos E.","family":"Vargas","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean\u2010Claude M.","family":"Rwigema","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah E.","family":"James","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathan Y.","family":"Yu","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Rong","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology Mayo Clinic Arizona Phoenix Arizona USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,2,22]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2007.06.063"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2007.08.040"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2008.09.043"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2006.11.004"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/0360-3016(94)00382-U"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(96)00341-0"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(03)00267-0"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20160312"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2004.11.009"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2006.01.050"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2006.10.026"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2010.02.001"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2014.10.049"},{"key":"e_1_2_8_15_1","first-page":"1","article-title":"Recent advances in surface guided radiation therapy","volume":"15","author":"Freislederer P","year":"2020","journal-title":"Radiat Oncol"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-12-814245-5.00002-5"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13246-023-01242-7"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2023.111204"},{"key":"e_1_2_8_19_1","first-page":"21","article-title":"Real\u2010time prostate gland motion and deformation during CyberKnife stereotactic body radiation therapy","volume":"1","author":"Gupta D","year":"2022","journal-title":"Appl Rad Oncol"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-020-01604-5"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2020.09.026"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2775667"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12824"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4958678"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(02)02882-1"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2899998"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2008.07.037"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/53\/16\/008"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3218845"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2012.07.2367"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12822"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1177\/15330338211063033"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2020.04.014"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2905225"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2009.02.012"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3355871"},{"key":"e_1_2_8_37_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-019-1447-1"},{"key":"e_1_2_8_38_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3121425"},{"key":"e_1_2_8_39_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4944737"},{"key":"e_1_2_8_40_1","unstructured":"HarrisC StephensM.A combined corner and edge detector. In:Alvey Vision Conference. Vol15.Citeseer;1988:10\u20105244."},{"key":"e_1_2_8_41_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11263-005-3848-x"},{"key":"e_1_2_8_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2006.07.1363"},{"key":"e_1_2_8_43_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3658566"},{"key":"e_1_2_8_44_1","volume-title":"Multiple View Geometry in Computer Vision","author":"Hartley R","year":"2003"},{"key":"e_1_2_8_45_1","doi-asserted-by":"crossref","unstructured":"HolzmannC HochgattererM.Measuring distance with mobile phones using single\u2010camera stereo vision. In:2012 32nd International Conference on Distributed Computing Systems Workshops.IEEE;2012:88\u201093.","DOI":"10.1109\/ICDCSW.2012.22"},{"key":"e_1_2_8_46_1","doi-asserted-by":"crossref","unstructured":"ReckerS Hess\u2010FloresM JoyKI.Statistical angular error\u2010based triangulation for efficient and accurate multi\u2010view scene reconstruction. In:2013 IEEE Workshop on Applications of Computer Vision (WACV).IEEE;2013:68\u201075.","DOI":"10.1109\/WACV.2013.6475001"},{"key":"e_1_2_8_47_1","doi-asserted-by":"crossref","DOI":"10.1177\/1729881417753692","article-title":"Active 6\u2010D position\u2010pose estimation of a spatial circle using monocular eye\u2010in\u2010hand system","volume":"15","author":"Ma X","year":"2018","journal-title":"Int J Adv Rob Syst"},{"key":"e_1_2_8_48_1","doi-asserted-by":"publisher","DOI":"10.1006\/cviu.1997.0547"},{"key":"e_1_2_8_49_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2003.10.017"},{"key":"e_1_2_8_50_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abe02a"},{"key":"e_1_2_8_51_1","unstructured":"KarvelisP oyvindlr.povilaskarvelis\/DataViz: v3.2.4 (v3.2.4).2024 Zenodo."},{"key":"e_1_2_8_52_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v17i4.6152"},{"key":"e_1_2_8_53_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2005.05.010"},{"key":"e_1_2_8_54_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2006.09.034"},{"key":"e_1_2_8_55_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2010.04.016"},{"key":"e_1_2_8_56_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2011.07.028"},{"key":"e_1_2_8_57_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2011.07.038"},{"key":"e_1_2_8_58_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2013.02.035"},{"key":"e_1_2_8_59_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00066-020-01633-9"},{"key":"e_1_2_8_60_1","doi-asserted-by":"publisher","DOI":"10.3390\/cancers15010016"},{"key":"e_1_2_8_61_1","doi-asserted-by":"publisher","DOI":"10.3390\/cancers15010040"},{"key":"e_1_2_8_62_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(02)02738-4"},{"key":"e_1_2_8_63_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2012.07.2077"},{"key":"e_1_2_8_64_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2013.05.019"}],"updated-by":[{"DOI":"10.1002\/mp.18009","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T00:00:00Z","timestamp":1754956800000}}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.17703","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T08:02:50Z","timestamp":1762934570000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/mp.17703"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,22]]},"references-count":63,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["10.1002\/mp.17703"],"URL":"https:\/\/doi.org\/10.1002\/mp.17703","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,22]]},"assertion":[{"value":"2024-06-13","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-05","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-22","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}