{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T17:07:14Z","timestamp":1789492034193,"version":"build-2803163510"},"reference-count":40,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T00:00:00Z","timestamp":1776988800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T00:00:00Z","timestamp":1776988800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"},{"start":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T00:00:00Z","timestamp":1776988800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T00:00:00Z","timestamp":1776988800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Single\u2010photon emission computed tomography (SPECT) is an indispensable examination for evaluating brain function to diagnose dementia. During head examination, the collimator makes contact with the shoulders, which often causes the patient discomfort. A new multifocal high\u2010resolution collimator (SMARTZOOM high resolution and extended [SZHRX]) can maintain image quality, even when there is distance between the patient and the collimator. Therefore, it may be a useful tool to prevent patient discomfort during head imaging.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>In this study, we evaluated spatial resolution, sensitivity, uniformity, and %contrast in several basic experiments using different phantoms to clarify the image quality of the multifocal collimator.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      We used\n                      <jats:sup>99m<\/jats:sup>\n                      Tc and\n                      <jats:sup>123<\/jats:sup>\n                      I nuclides, which were sealed in several phantoms and imaged using SZHRX. The rotation radius for SZHRX was varied from 24\u201334.5\u00a0cm. For comparison, low\u2010energy high\u2010resolution (LEHR) and low\u2013medium energy general purpose (LMEGP) images were acquired with a rotation radius of 14\u00a0cm. Spatial resolution, sensitivity, uniformity, and %contrast were calculated from the images obtained using each phantom and collimator.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      For both\n                      <jats:sup>99m<\/jats:sup>\n                      Tc and\n                      <jats:sup>123<\/jats:sup>\n                      I, the wider the radius of rotation, the larger the full\u2010width half maximum (FWHM) of SZHRX. The FWHM of SZHRX was larger than that of LEHR, and the FWHM of SZHRX was smaller than that of LMEGP. The sensitivity of SZHRX increased as the distance increased, regardless of nuclides. For\n                      <jats:sup>99m<\/jats:sup>\n                      Tc, SZHRX had higher sensitivity than LEHR. The sensitivity of SZHRX for\n                      <jats:sup>123<\/jats:sup>\n                      I was lower than that of LMEGP at short distances, with the same sensitivity at a radius of rotation of 26\u201328\u00a0cm. The coefficient of variation (CV) of\n                      <jats:sup>99m<\/jats:sup>\n                      Tc for SZHRX was lower than that for LEHR, and the further the distance, the lower the CV. For\n                      <jats:sup>123<\/jats:sup>\n                      I, the CVs of SZHRX and LMEGP were comparable. The %contrast of SZHRX worsened as the rotation radius increased. For\n                      <jats:sup>99m<\/jats:sup>\n                      Tc, the %contrast of SZHRX was lower than that of LEHR. For\n                      <jats:sup>123<\/jats:sup>\n                      I, the %contrast of SZHRX and LMEGP were comparable.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>It is possible to acquire images with high spatial resolution and uniformity, even if the rotation radius is widened by the use of SZHRX. The image quality of SZHRX obtained in this study will be helpful for future clinical applications.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mp.70451","type":"journal-article","created":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T08:15:54Z","timestamp":1777018554000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Performance evaluation of a clinical SPECT system with multifocal collimator for brain studies"],"prefix":"10.1002","volume":"53","author":[{"given":"Tamaki","family":"Otani","sequence":"first","affiliation":[{"name":"Department of Medical Imaging\/Nuclear Medicine, Tokushima University Graduate School of Biomedical Sciences Tokushima University  Tokushima Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yamato","family":"Kunikane","sequence":"additional","affiliation":[{"name":"Department of Radiology Tokushima University Hospital  Tokushima Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoru","family":"Takashi","sequence":"additional","affiliation":[{"name":"Department of Radiology Tokushima University Hospital  Tokushima Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shota","family":"Azane","sequence":"additional","affiliation":[{"name":"Department of Radiology Tokushima University Hospital  Tokushima Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akihiko","family":"Fujita","sequence":"additional","affiliation":[{"name":"Department of Radiology Tokushima University Hospital  Tokushima Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noritake","family":"Matsuda","sequence":"additional","affiliation":[{"name":"Department of Radiology Tokushima University Hospital  Tokushima Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masafumi","family":"Amano","sequence":"additional","affiliation":[{"name":"Department of Radiology Tokushima University Hospital  Tokushima Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,4,24]]},"reference":[{"issue":"11","key":"e_1_2_8_2_1","first-page":"1892","article-title":"Characterization of technetium\u201099m\u2010L,L\u2010ECD for brain perfusion imaging, part 1: pharmacology of technetium\u201099m ECD in nonhuman primates","volume":"30","author":"Walovitch RC","year":"1989","journal-title":"J Nucl Med"},{"issue":"11","key":"e_1_2_8_3_1","first-page":"1902","article-title":"Characterization of technetium\u201099m\u2010L,L\u2010ECD for brain perfusion imaging, part 2: biodistribution and brain imaging in humans","volume":"30","author":"L\u00e9veill\u00e9 J","year":"1989","journal-title":"J Nucl Med"},{"issue":"4","key":"e_1_2_8_4_1","first-page":"587","article-title":"SPECT imaging of normal subjects with technetium\u201099m\u2010HMPAO and technetium\u201099m\u2010ECD","volume":"38","author":"Koyama M","year":"1997","journal-title":"J Nucl Med"},{"issue":"11","key":"e_1_2_8_5_1","first-page":"1749","article-title":"Comparison of technetium\u201099m\u2010HMPAO and technetium\u201099m\u2010ECD cerebral SPECT images in Alzheimer's disease","volume":"37","author":"vanDyck CH","year":"1996","journal-title":"J Nucl Med"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1212\/wnl.50.6.1563"},{"issue":"7","key":"e_1_2_8_7_1","first-page":"1155","article-title":"Longitudinal evaluation of early Alzheimer's disease using brain perfusion SPECT","volume":"41","author":"Kogure D","year":"2000","journal-title":"J Nucl Med"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259\u2010004\u20101704\u20109"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11604\u2010007\u20100132\u20108"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.62.2.133"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.3390\/cells8080872"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF00843705"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s002590050434"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLU.0b013e31828da362"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12350\u2010016\u20100546\u20108"},{"key":"e_1_2_8_16_1","first-page":"1023","article-title":"A special cut\u2010off gamma camera for high\u2010resolution SPECT of the head","volume":"25","author":"Larsson SA","year":"1984","journal-title":"J Nucl Med"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12149\u2010015\u20100965\u20107"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/MNM.0000000000000609"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12149\u2010018\u20101310\u20108"},{"key":"e_1_2_8_20_1","first-page":"810","article-title":"Design and clinical utility of a fan beam collimator for SPECT imaging of the head","volume":"27","author":"Tsui BMW","year":"1986","journal-title":"J Nucl Med"},{"issue":"2","key":"e_1_2_8_21_1","first-page":"4116","article-title":"Image characteristics of brain perfusion SPECT\/CT using a new multi\u2010focal collimator: comparison with conventional SPECT with LEHR collimator","volume":"63","author":"Shibutani T","year":"2022","journal-title":"J Nucl Med"},{"issue":"2","key":"e_1_2_8_22_1","article-title":"Image quality of iodine\u2010123 brain SPECT with multi\u2010focal collimator: comparison with conventional SPECT using several parallel\u2010hole collimators","volume":"65","author":"Shibutani T","year":"2024","journal-title":"J Nucl Med"},{"key":"e_1_2_8_23_1","first-page":"2019","article-title":"Quantitative mapping of regional cerebral blood flow using iodine\u2010123\u2010IMP and SPECT","volume":"35","author":"Iida H","year":"1994","journal-title":"J Nucl Med"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12149\u2010021\u201001634\u20103"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658\u2010016\u20100159\u2010y"},{"issue":"1","key":"e_1_2_8_26_1","first-page":"42","article-title":"Relationship between physical parameters and visual analysis for assessment of image quality: a multi\u2010center and multi\u2010vendor phantom study in brain SPECT","volume":"13","author":"Sugiura A","year":"2025","journal-title":"Asia Ocean J Nucl Med Biol"},{"key":"e_1_2_8_27_1","unstructured":"ClintonJB Massan\u00e9sF VijaAH SMARTZOOM HRX White paper: Applications and benefits in SPECT and SPECT\/CT brain imaging. siemens\u2010healthineers.com website. [cited Mar 16 2026]. Retrieved from:https:\/\/marketing.webassets.siemens\u2010healthineers.com\/6935cb175ee1c7c2\/0dbb16bb879d\/MI\u2010SMARTZOOM\u2010HRX\u2010white\u2010paper\u2010QR700013628.PDF"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140\u20106736(98)10327\u20106"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259\u2010005\u20101779\u2010y"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02995286"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12194\u2010012\u20100168\u2010z"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12149\u2010013\u20100785\u20106"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.109.071571"},{"key":"e_1_2_8_34_1","first-page":"34","article-title":"Simultaneous 3\u2010dimensional resolution correction in SPECT reconstruction with an ordered\u2010subsets expectation maximization algorithm","volume":"35","author":"Takahashi Y","year":"2007","journal-title":"J Nucl Med Technol"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.119.227140"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00415\u2010019\u201009330\u2010z"},{"key":"e_1_2_8_37_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10072\u2010003\u20100103\u20105"},{"key":"e_1_2_8_38_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnmt.113.131904"},{"key":"e_1_2_8_39_1","doi-asserted-by":"publisher","DOI":"10.1007\/s002590000387"},{"key":"e_1_2_8_40_1","first-page":"17","article-title":"Cerebral blood flow tomography: xenon\u2010133 compared with isopropyl amphetamine\u2010iodine\u2010123: concise communication","volume":"24","author":"Lassen NA","year":"1983","journal-title":"J Nucl Med"},{"key":"e_1_2_8_41_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.21.7.1059"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.70451","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mp.70451","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.70451","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T16:44:40Z","timestamp":1789490680000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/mp.70451"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,24]]},"references-count":40,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["10.1002\/mp.70451"],"URL":"https:\/\/doi.org\/10.1002\/mp.70451","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,24]]},"assertion":[{"value":"2024-03-05","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-07","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-24","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70451"}}