{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T17:06:53Z","timestamp":1789492013638,"version":"build-2803163510"},"reference-count":31,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2026,5,25]],"date-time":"2026-05-25T00:00:00Z","timestamp":1779667200000},"content-version":"vor","delay-in-days":24,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["32427801"],"award-info":[{"award-number":["32427801"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Magnetic resonance imaging (MRI) provides high soft tissue contrast and accurate spatial guidance for interventional procedures. However, metallic needles introduce severe signal voids and phase accumulation that can obscure surrounding anatomy and target lesions, thus compromising procedural accuracy and increasing the risk of injury to adjacent healthy\u00a0tissue.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To reduce metal\u2010induced artifacts and shorten acquisition time in MRI\u2010guided interventions while improving imaging precision during needle\u00a0guidance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We propose a simultaneous multi\u2010band multi\u2010spectral imaging (SMB\u2010MSI) sequence that uses multi\u2010band radiofrequency pulses, designed from off\u2010resonance field maps estimated using low\u2010resolution two\u2010dimensional multi\u2010spectral imaging (2D MSI) data to acquire multiple spectral bins concurrently. In the current implementation, the proposed SMB\u2010MSI data were acquired from two simultaneously excited bins and reconstructed using direct complex summation.The performance of SMB\u2010MSI was evaluated against fast low\u2010angle shot (FLASH), two\u2010dimensional fast spin echo (2D FSE), and conventional MSI with different numbers of spectral bins using phantom experiments and ex vivo porcine liver models. Puncture needles were imaged at 0.35 T and 1.5 T. Metal\u2010induced artifact width was quantified using the full width at half maximum (FWHM), and image signal\u2010to\u2010noise ratios (SNRs) were assessed in both phantom and ex vivo porcine liver experiments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>SMB\u2010MSI markedly reduced artifact width (e.g., 3.8 vs. 5.8 mm and 4.2 vs. 6.6 mm in phantom experiments, and 2.3 vs. 3.7 mm, 2.8 vs. 4.2 mm at 0.35 T and 1.5 T, respectively, relative to five\u2010bin MSI), while shortening acquisition time by approximately 80% compared with five\u2010bin MSI. In addition, SMB\u2010MSI provided higher SNR than conventional MSI in both phantom and ex vivo experiments. Needle tips were clearly visualized with minimal geometric distortion. Consistent improvements were observed in both phantom and ex vivo liver experiments at both field\u00a0strengths.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>SMB\u2010MSI provides rapid and accurate MRI\u2010guided needle visualization with substantially reduced metal\u2010induced artifacts. This approach shows promise for improving the efficiency and precision of MRI\u2010guided interventional\u00a0procedures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mp.70510","type":"journal-article","created":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T04:10:04Z","timestamp":1779768604000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Simultaneous multi\u2010band multi\u2010spectral imaging using multi\u2010band RF excitation for accelerated metal artifact reduction in MRI\u2010guided interventions"],"prefix":"10.1002","volume":"53","author":[{"given":"Penghui","family":"Luo","sequence":"first","affiliation":[{"name":"Medical Imaging Center, Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiantai","family":"Zhou","sequence":"additional","affiliation":[{"name":"Medical Imaging Center, Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Chen","sequence":"additional","affiliation":[{"name":"High Magnetic Field Laboratory, Hefei Institutes of Physical Science Chinese Academy of Sciences Hefei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Changliang","family":"Wang","sequence":"additional","affiliation":[{"name":"Medical Imaging Center, Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kecheng","family":"Yuan","sequence":"additional","affiliation":[{"name":"Medical Imaging Center, Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoyan","family":"Huang","sequence":"additional","affiliation":[{"name":"Medical Imaging Center, Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yufu","family":"Zhou","sequence":"additional","affiliation":[{"name":"Medical Imaging Center, Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuechun","family":"Jiao","sequence":"additional","affiliation":[{"name":"Anhui Women and Children's Health Center Hefei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fulang","family":"Qi","sequence":"additional","affiliation":[{"name":"Medical Imaging Center, Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bensheng","family":"Qiu","sequence":"additional","affiliation":[{"name":"Medical Imaging Center, Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,5,25]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2005.03.033"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.17880"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910360423"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25708"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mric.2015.05.006"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.27411"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mric.2015.05.007"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-025-04021-x"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.596162"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21967"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21856"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22523"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26724"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27056"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.70036"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26209"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.11.7364"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-025-90645-5"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26597"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910040604"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910060315"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25897"},{"key":"e_1_2_10_24_1","unstructured":"WongE.Optimized phase schedules for minimizing peak RF power in simultaneous multi\u2010slice RF excitation pulses. In:Proceedings of the 20th Annual Meeting of ISMRM 488 Melbourne Australia.2012;20:2209."},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26610"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1109\/42.75611"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2022.3231782"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.diii.2020.12.007"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25858"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24685"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.23152"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2017.11.022"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.70510","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mp.70510","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.70510","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T16:42:02Z","timestamp":1789490522000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/mp.70510"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":31,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5]]}},"alternative-id":["10.1002\/mp.70510"],"URL":"https:\/\/doi.org\/10.1002\/mp.70510","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"2026-02-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-11","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-25","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70510"}}