{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T17:12:19Z","timestamp":1784049139869,"version":"3.55.0"},"reference-count":11,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T00:00:00Z","timestamp":1780876800000},"content-version":"vor","delay-in-days":7,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Accurate 2D characterization of X\u2010ray tube focal spot dimensions (FS) and detector Point Spread Function (PSF) is essential for radiographic quality assurance, yet traditional methods (pinhole, slit cameras) are either limited to 1D characterization or require impractical setups. This article introduces SCOPE\u2010XR, an open\u2010source Python framework that implements and generalizes a previously established reconstruction technique, providing fully automated 2D estimation of FS distributions and detector PSF from a single radiograph of a basic test object. The software is targeted at medical physicists, researchers, and clinical quality control personnel to streamline and enhance routine acceptance\u00a0testing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Development and Validation Methods<\/jats:title>\n                    <jats:p>SCOPE\u2010XR processes radiographic images to estimate the shape and dimensions of FS and PSF distributions. The underlying algorithm utilizes automatic circle detection, derivation, pseudo\u2010CT reconstruction and incorporates an oversampling strategy to improve PSF reconstruction accuracy at limited sampling densities. The software was validated against both virtually simulated datasets and experimental clinical acquisitions, demonstrating high fidelity in characterizing source morphology and detector\u00a0responses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Data Format and Usage Notes<\/jats:title>\n                    <jats:p>\n                      SCOPE\u2010XR is implemented in Python and is cross\u2010platform compatible (Windows, macOS, Linux), requiring minimal computational resources. The software accepts standard radiographic image formats (e.g., [DICOM, TIFF, RAW]) as input and outputs 2D emission profiles, quantitative dimensional metrics, and performance plots. A small dataset of virtual and experimental acquisitions is included as an example for benchmarking and reproducibility. The source code, datasets, and comprehensive documentation are publicly accessible via its public repository:\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"https:\/\/doi.org\/10.15161\/oar.it\/hrrqs-cn059\">https:\/\/doi.org\/10.15161\/oar.it\/hrrqs\u2010cn059<\/jats:ext-link>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Potential Applications<\/jats:title>\n                    <jats:p>SCOPE\u2010XR provides a practical, fully automated alternative to traditional measurement techniques. Its primary clinical and scientific applications include the streamlined evaluation of imaging system performance during acceptance testing, routine quality control, and system design\u00a0characterization.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mp.70513","type":"journal-article","created":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T03:19:03Z","timestamp":1780975143000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A python framework for single\u2010image characterization of X\u2010ray focal spot distribution and detector point spread function"],"prefix":"10.1002","volume":"53","author":[{"ORCID":"https:\/\/orcid.org\/0009-0002-5163-660X","authenticated-orcid":false,"given":"Jacopo","family":"Altieri","sequence":"first","affiliation":[{"name":"Department of Physics and Earth Sciences University of Ferrara Ferrara Italy"},{"name":"Istituto Nazionale di Fisica Nucleare Ferrara Division Ferrara Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4177-6756","authenticated-orcid":false,"given":"Paolo","family":"Cardarelli","sequence":"additional","affiliation":[{"name":"Istituto Nazionale di Fisica Nucleare Ferrara Division Ferrara Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8500-6764","authenticated-orcid":false,"given":"Giovanni","family":"Di Domenico","sequence":"additional","affiliation":[{"name":"Department of Physics and Earth Sciences University of Ferrara Ferrara Italy"},{"name":"Istituto Nazionale di Fisica Nucleare Ferrara Division Ferrara Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2494-8993","authenticated-orcid":false,"given":"Angelo","family":"Taibi","sequence":"additional","affiliation":[{"name":"Department of Physics and Earth Sciences University of Ferrara Ferrara Italy"},{"name":"Istituto Nazionale di Fisica Nucleare Ferrara Division Ferrara Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,6,8]]},"reference":[{"key":"e_1_2_9_2_1","unstructured":"International Electrotechnical Commission Medical electrical equipment \u2014 X\u2010ray tube assemblies for medical diagnosis \u2014 Focal spot dimensions and related characteristics. IEC 60336:2020 Edition 5.0 (2020) includes Corrigendum1 (2022)."},{"key":"e_1_2_9_3_1","unstructured":"International Electrotechnical Commission Medical electrical equipment \u2014 characteristics of digital X\u2010ray imaging devices \u2014 Part 1\u20101: determination of the detective quantum efficiency \u2014 Detectors used in radiographic imaging. IEC 62220\u20101\u20101:2015 Edition 1.0(2015)."},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/18\/4\/006"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3567503"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4938414"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1364\/OE.542925"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.598165"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1145\/361237.361242"},{"key":"e_1_2_9_10_1","first-page":"13","volume-title":"Digital Mammography","author":"Yaffe MJ","year":"2020"},{"key":"e_1_2_9_11_1","doi-asserted-by":"crossref","unstructured":"JainA PanseA BednarekDR RudinS Focal spot measurements using a digital flat panel detector. In:LoJY SpitzUA eds.Medical Imaging 2014: Physics of Medical Imaging2014;9033:1488\u20131493.","DOI":"10.1117\/12.2043057"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6501\/ac6225"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.70513","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mp.70513","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.70513","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T16:57:04Z","timestamp":1784048224000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/mp.70513"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":11,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["10.1002\/mp.70513"],"URL":"https:\/\/doi.org\/10.1002\/mp.70513","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6]]},"assertion":[{"value":"2026-01-28","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-19","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-08","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70513"}}