{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T20:32:05Z","timestamp":1786393925734,"version":"build-2736575974"},"reference-count":75,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Accurate quantification of lutetium\u2010177 (\n                    <jats:sup>177<\/jats:sup>\n                    Lu) activity in SPECT\/CT imaging is essential for a further development of\n                    <jats:sup>177<\/jats:sup>\n                    Lu\u2010based peptide receptor radionuclide therapy (PRRT) in establishing absorbed dose\u2010effect relationships. This review summarizes the reported accuracy of quantitative\n                    <jats:sup>177<\/jats:sup>\n                    Lu SPECT\/CT imaging and highlights key sources of variability, including partial\u2010volume effect (PVE) in small volumes. A systematic review was conducted according to PRISMA guidelines. MEDLINE, EMBASE, and Web of Science databases were searched with no language restrictions. Original studies explicitly reporting on the accuracy of\n                    <jats:sup>177<\/jats:sup>\n                    Lu activity quantifications in physical SPECT\/CT measurements were included. Reported percentage error\/deviation and recovery coefficient (RC) were extracted and compiled, with studies grouped by object type (geometric phantoms, anthropomorphic phantoms, and patient data). The literature search identified 630 records, of which 46 studies were included for analysis. Percentage errors of quantifications were found to constitute a large range (\u2212102% to 285%). The recovery of\n                    <jats:sup>177<\/jats:sup>\n                    Lu activity from small volumes is inherently limited by PVE. The application of PVC has led to improvements in the accuracy and precision of quantifications on small volumes in phantom imaging. The accuracy of\n                    <jats:sup>177<\/jats:sup>\n                    Lu activity quantifications in SPECT\/CT imaging remains heterogenous across literature, is subject to large variability and will be degraded by PVE when imaging small volumes. The data suggests that the implementation of standardized procedures including standardization of calibration, reconstruction, segmentation, and PVC assumptions may lead to an improved accuracy and precision of quantitative\n                    <jats:sup>177<\/jats:sup>\n                    Lu SPECT\/CT imaging in clinical practice, thereby allowing the further development of\n                    <jats:sup>177<\/jats:sup>\n                    Lu\u2010based PRRT.\n                  <\/jats:p>","DOI":"10.1002\/mp.70554","type":"journal-article","created":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T17:22:19Z","timestamp":1782926539000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy of quantitative\n                    <sup>177<\/sup>\n                    Lu SPECT\/CT imaging: A systematic review"],"prefix":"10.1002","volume":"53","author":[{"given":"Julian C. J.","family":"van Oorschodt","sequence":"first","affiliation":[{"name":"Faculty of Medicine and Health The University of Sydney  Sydney New South Wales Australia"},{"name":"Department of Applied Physics Eindhoven University of Technology  Eindhoven The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guy D.","family":"Eslick","sequence":"additional","affiliation":[{"name":"Clinical Links Using Evidence\u2010based Data (CLUED) Consulting Pty Ltd  Sydney New South Wales Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Ugander","sequence":"additional","affiliation":[{"name":"Faculty of Medicine and Health The University of Sydney  Sydney New South Wales Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carola","family":"van Pul","sequence":"additional","affiliation":[{"name":"Department of Applied Physics Eindhoven University of Technology  Eindhoven The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enid M.","family":"Eslick","sequence":"additional","affiliation":[{"name":"Faculty of Medicine and Health The University of Sydney  Sydney New South Wales Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,7,1]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.euo.2020.07.002"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmrs.227"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(21)00237-3"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-021-00422-2"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2016.09.014"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.122.264677"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.122.264398"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-020-0275-6"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clon.2020.11.008"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-020-0278-3"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2018.12.029"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.semnuclmed.2022.01.004"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.117.200170"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/61\/14\/5107"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.apradiso.2016.03.007"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/MNM.0000000000000079"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.115.159012"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-015-0123-2"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.112.111476"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-013-2542-4"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.semnuclmed.2021.11.004"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0182888"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-021-00397-0"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-018-0213-z"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.118.211094"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-025-07612-5"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-024-00697-1"},{"issue":"1","key":"e_1_2_9_29_1","first-page":"44","article-title":"Partial volume effect in SPECT & PET imaging and impact on radionuclide dosimetry estimates","volume":"11","author":"Marquis H","year":"2023","journal-title":"Asia Ocean J Nucl Med Biol"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/57\/21\/R119"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2023.103174"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-022-00446-2"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.125.270168"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.124.268520"},{"key":"e_1_2_9_35_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361\u20106560\/acd982"},{"key":"e_1_2_9_36_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-021-05471-4"},{"key":"e_1_2_9_37_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-023-00561-8"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-025-00772-1"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLU.0000000000003169"},{"key":"e_1_2_9_40_1","doi-asserted-by":"publisher","DOI":"10.1102\/1470-7330.2011.0012"},{"key":"e_1_2_9_41_1","doi-asserted-by":"crossref","unstructured":"D'ambrosioL AlojL MoriscoA et\u00a0al.Quantitative177Lu\u2010SPECT\/CT imaging and validation of a commercial dosimetry software. EANM Abstracts 2013.Eur J Nucl Med Mol Imaging.2015;40(Suppl2):S175.","DOI":"10.1007\/s00259-013-2535-3"},{"key":"e_1_2_9_42_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-015-3174-7"},{"key":"e_1_2_9_43_1","unstructured":"GaudinEO MeJF UribeC CellerA Despr'esP BeauregardJM.Impact of resolution recovery on quantitative SPECT\/CT reconstructions with Tc\u201099m adn Lu\u2010177.in EANM'14.2014;Oct:362."},{"key":"e_1_2_9_44_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2018.11.009"},{"key":"e_1_2_9_45_1","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12991"},{"issue":"11","key":"e_1_2_9_46_1","first-page":"1671","article-title":"Absolute quantification provided by Lu SPECT images recorded by a high\u2010speed 360 degree whole\u2010body CZT camera: a feasibility study on phantom and patient","volume":"61","author":"Imbert LCM","year":"2020","journal-title":"J Nucl Med"},{"key":"e_1_2_9_47_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.119.239277"},{"key":"e_1_2_9_48_1","unstructured":"KupferschlaegerJ.Quantification of 177\u2010Lu and 131\u2010I: a phantom study.EANM\u201917.2017."},{"key":"e_1_2_9_49_1","unstructured":"LamTO.ME Evaluation of quantitative SPECT using a Jaszczak phantom with hot and cold spheres. EPSM 2019.2020;Jan."},{"key":"e_1_2_9_50_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-022-00476-w"},{"key":"e_1_2_9_51_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-017-0174-7"},{"key":"e_1_2_9_52_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-021-00362-x"},{"key":"e_1_2_9_53_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-023-00526-x"},{"key":"e_1_2_9_54_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-016-0148-1"},{"key":"e_1_2_9_55_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab2a22"},{"key":"e_1_2_9_56_1","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/1497\/1\/012025"},{"key":"e_1_2_9_57_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11307-014-0806-4"},{"key":"e_1_2_9_58_1","first-page":"1363","article-title":"Intrinsic or extrinsic uniformity maps using 177Lu on a GE Discovery 870 CZT gamma camera","volume":"60","author":"Sandstrom MSA","year":"2019","journal-title":"J Nucl Med"},{"key":"e_1_2_9_59_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13550-018-0459-4"},{"key":"e_1_2_9_60_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/57\/18\/5733"},{"key":"e_1_2_9_61_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-016-0170-3"},{"key":"e_1_2_9_62_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/60\/21\/8329"},{"issue":"2","key":"e_1_2_9_63_1","first-page":"S110","article-title":"Quantitation of Lu\u2010177 SPECT: oSEM and Bayesian reconstruction with state\u2010of\u2010the\u2010art compensation methods","volume":"40","author":"Hippel\u00e4inen E","year":"2013","journal-title":"EANM abstracts"},{"key":"e_1_2_9_64_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13550-016-0172-0"},{"key":"e_1_2_9_65_1","unstructured":"McKayE.Quantitative reconstruction of lu\u2010177 tomography.42nd Annual Scientific Meeting of the Australian and New Zealand Society of Nuclear Medicine.2012;September."},{"key":"e_1_2_9_66_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abca52"},{"key":"e_1_2_9_67_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2019.01.013"},{"key":"e_1_2_9_68_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.121.262925"},{"key":"e_1_2_9_69_1","unstructured":"MarciniakCME.Dead time correction in lu\u2010177 dotatate therapy imaging. Oral Presentations2015. April."},{"key":"e_1_2_9_70_1","first-page":"2137","article-title":"On the quantitative accuracy of xSPECT quant based renal uptake determination for internal dosimetry in 177Lu\u2010PSMA radioligand therapy","volume":"59","author":"Tran\u2010Gia J","year":"2018","journal-title":"J Nucl Med"},{"key":"e_1_2_9_71_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1120-1797(22)00435-5"},{"key":"e_1_2_9_72_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-016-0169-9"},{"key":"e_1_2_9_73_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/61\/22\/7975"},{"key":"e_1_2_9_74_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.119.231480"},{"key":"e_1_2_9_75_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40658-022-00512-9"},{"key":"e_1_2_9_76_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-018-4136-7"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.70554","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mp.70554","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.70554","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T19:54:48Z","timestamp":1786391688000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/mp.70554"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":75,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2026,7]]}},"alternative-id":["10.1002\/mp.70554"],"URL":"https:\/\/doi.org\/10.1002\/mp.70554","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"2025-06-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-05-25","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-01","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70554"}}