{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,21]],"date-time":"2026-11-21T11:14:54Z","timestamp":1795259694052,"version":"4.10.3"},"reference-count":54,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T00:00:00Z","timestamp":1792540800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T00:00:00Z","timestamp":1792540800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["aapm.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2026,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Virtual imaging trials in medicine (VITMs) rely on in silico platforms that simulate tests on volunteers. In VITMs, a simulation software program replicates the imaging apparatus, and the patient is replaced by a digital phantom. Recent innovations in the field of x\u2010ray breast imaging supported a widespread development of VITM platforms and the need for appropriate evaluations and validations. In this context, digital patients are usually created via mathematical models based on a priori anatomical assumptions, that permit the reproduction of a large population variability with arbitrarily fine spatial resolutions. On the other hand, data\u2010driven digital phantoms\u2014derived from 3D images of the breast\u2014feature realistic shape and glandular tissue distribution; however, they are limited by the scarce availability of 3D breast images with relatively high image quality and by the spatial resolution of the used clinical data. These are largely adopted in dosimetry evaluations, but no single generally adopted criterion for realism evaluations\u2014which depend on the intended clinical task\u2014in simulated images exists.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This work aims to evaluate the realism of digital mammography (DM) and digital breast tomosynthesis (DBT) images generated for VITMs by adopting data\u2010driven digital breast phantoms via objective parameters and subjective analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>DM and DBT images were simulated via an open\u2010source simulation platform. The cohort of data\u2010driven digital breast phantoms included 126 cases from an open access database. The subjective analysis was conducted via a two\u2010alternative forced choice (2AFC) test and a Visual Grading Analysis (VGA) involving four radiologists. In the 2AFC test, radiologists were asked to recognize regions of interest (ROIs) extracted from simulated images, by comparison with a second set from clinical images. VGA evaluated image realisms based on a scoring scale. The objective analysis was conducted by evaluating the \u03b2 parameter in images, this characterizing the magnitude of the anatomical noise.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The \u03b2 parameter was 2.71\u00a0\u00b1\u00a00.40 in DM and 3.09\u00a0\u00b1\u00a00.28 in DBT. From the analysis of the noise spectra of DM images, the presence of artifacts caused by the phantom voxelization was evident and prominent for thinner breasts. Radiologists distinguished ROIs from the simulated dataset from those from a clinical dataset in the vast majority of cases. Low pass filters on simulated images had little influence on DBT images; however, the sensitivity in detecting simulated images was no lower than 83%. VGA average scoring acknowledged some degree of image realism, outlining the presence of artifacts or unrealistic image regions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Objective evaluation reported that the \u03b2 parameter evaluated for DM and DBT images simulated by adopting data\u2010driven digital breast phantoms was in line with that from clinical images. A 2AFC test demonstrated that radiologists distinguish between simulated and real images. The subjective analysis also permitted the identification of the main features characterizing simulated images that include voxelization artifacts, the absence of fine structures and of a realistic adipose pattern in simulated images. However, realism should be verified with regard to a specific question of interest under investigation in a VITM.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mp.70715","type":"journal-article","created":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T17:55:03Z","timestamp":1792605303000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Anatomical noise and visual realism assessment in simulated mammography and digital breast tomosynthesis images from data\u2010driven breast phantoms"],"prefix":"10.1002","volume":"53","author":[{"given":"Antonio","family":"Sarno","sequence":"first","affiliation":[{"name":"Dipartimento di Fisica \u2018A Pontremoli\u2019 Universit\u00e0 di Milano  Milano Italy"},{"name":"INFN sez di Milano  Milano Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niccol\u00f2","family":"Storchi","sequence":"additional","affiliation":[{"name":"Dipartimento di Fisica \u2018A Pontremoli\u2019 Universit\u00e0 di Milano  Milano Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tommaso","family":"Nava","sequence":"additional","affiliation":[{"name":"Dipartimento di Fisica \u2018A Pontremoli\u2019 Universit\u00e0 di Milano  Milano Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elvira","family":"Guerriero","sequence":"additional","affiliation":[{"name":"ASST Melegnano e Martesana  Milano Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna Teresa","family":"Pandiscia","sequence":"additional","affiliation":[{"name":"ASST Melegnano e Martesana  Milano Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raffaele Maria","family":"Tucciariello","sequence":"additional","affiliation":[{"name":"Department of Medical Physics IRCCS CROB  Rionero in Vulture Potenza Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuseppina Di","family":"Nardo","sequence":"additional","affiliation":[{"name":"UOC Diagnostica per immagini IRCCS CROB  Rionero in Vulture Potenza Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Villonio","sequence":"additional","affiliation":[{"name":"UOC Diagnostica per immagini IRCCS CROB  Rionero in Vulture Potenza Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesca Saveria","family":"Maddaloni","sequence":"additional","affiliation":[{"name":"Dipartimento di Fisica \u2018A Pontremoli\u2019 Universit\u00e0 di Milano  Milano Italy"},{"name":"INFN sez di Milano  Milano Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alice","family":"Barcella","sequence":"additional","affiliation":[{"name":"Dipartimento di Fisica \u2018A Pontremoli\u2019 Universit\u00e0 di Milano  Milano Italy"},{"name":"INFN sez di Milano  Milano Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivan","family":"Veronese","sequence":"additional","affiliation":[{"name":"Dipartimento di Fisica \u2018A Pontremoli\u2019 Universit\u00e0 di Milano  Milano Italy"},{"name":"INFN sez di Milano  Milano Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Torresin","sequence":"additional","affiliation":[{"name":"Dipartimento di Fisica \u2018A Pontremoli\u2019 Universit\u00e0 di Milano  Milano Italy"},{"name":"INFN sez di Milano  Milano Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,10,21]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.17442"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13063\u2010020\u201005002\u2010w"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.17587"},{"issue":"1","key":"e_1_2_8_5_1","first-page":"1","article-title":"BreastSimulator: a software platform for breast x\u2010ray imaging research","volume":"2","author":"Bliznakova K","year":"2012","journal-title":"Journ Biom Graph Comp"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/59\/15\/4275"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1117\/12.2294934"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361\u20106560\/ab55ac"},{"issue":"4","key":"e_1_2_8_9_1","first-page":"042804","article-title":"Verification of the accuracy of a hybrid breast imaging simulation framework for virtual clinical trial applications","volume":"7","author":"Vancoillie L","year":"2020","journal-title":"Journ Med Im"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2020.05.007"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1109\/TRPMS.2024.3349563"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cpc.2020.107779"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361\u20106560\/ac9a34"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.70215"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2025.111121"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4919441"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2020.11.025"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2022.110715"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.17873"},{"key":"e_1_2_8_20_1","first-page":"72","article-title":"A new, open\u2010source, multi\u2010modality digital breast phantom","volume":"9783","author":"Graff CG","year":"2016","journal-title":"Proc. SPIE 9783 Medical Imaging 2016: Physics of Medical Imaging"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3697523"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/48\/22\/006"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2021.3087958"},{"key":"e_1_2_8_24_1","doi-asserted-by":"crossref","unstructured":"TucciarielloRM BarcaP Del SartoD et\u00a0al.Voxelized Breast Phantoms for Dosimetry in Mammography.BIOINFORMATICS2021 154\u2013161.","DOI":"10.5220\/0010322900002865"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4737025"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4794924"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4937597"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1117\/12.2564273"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3140588"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.14826"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.15785"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.16842"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2025.105043"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361\u20106560\/ae556c"},{"key":"e_1_2_8_35_1","first-page":"418","article-title":"Breast tomosynthesis reconstruction using TIGRE software tool","volume":"10718","author":"Malet A","year":"2018","journal-title":"Proc. SPIE 10718 14th International Workshop on Breast Imaging (IWBI2018)"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11259\u2010010\u20109413\u20102"},{"key":"e_1_2_8_37_1","doi-asserted-by":"crossref","unstructured":"TenevaT SarnoA DukovN et\u00a0al Subjective Evaluation of Phantoms in X\u2010ray Breast Imaging Research: insights from Bulgaria. InNordic\u2010Baltic Conference on Biomedical Engineering and Medical Physics(pp.311\u2013319).Springer Nature Switzerland.2025","DOI":"10.1007\/978-3-031-96538-8_27"},{"key":"e_1_2_8_38_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13534\u2010023\u201000339\u2010y"},{"key":"e_1_2_8_39_1","unstructured":"BudaM SahaA WalshR et\u00a0al.Breast Cancer Screening\u2014Digital Breast Tomosynthesis (BCS\u2010DBT). (Version 5).The Cancer Imaging Archive.2020doi:10.7937\/E4WT\u2010CD02"},{"key":"e_1_2_8_40_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361\u20106560\/aa6ca3"},{"key":"e_1_2_8_41_1","doi-asserted-by":"publisher","DOI":"10.1117\/12.3006839"},{"key":"e_1_2_8_42_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radphyschem.2023.111241"},{"key":"e_1_2_8_43_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.1355308"},{"key":"e_1_2_8_44_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3685462"},{"key":"e_1_2_8_45_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/58\/6\/1663"},{"key":"e_1_2_8_46_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4736422"},{"key":"e_1_2_8_47_1","unstructured":"US Food & Drug Administration.Assessing the Credibility of Computational Modeling and Simulation in Medical Device Sub\u2010missions. US Food & Drug Administration; 2024. Accessed in September2025.https:\/\/www.fda.gov\/media\/154985\/download"},{"issue":"1","key":"e_1_2_8_48_1","article-title":"Synthetic data in radiological imaging: current state and future outlook","volume":"1","author":"Sizikova E","year":"2012","journal-title":"BJR| Artificial Intelligence"},{"key":"e_1_2_8_49_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330\u2010021\u201008197\u2010x"},{"key":"e_1_2_8_50_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4928676"},{"key":"e_1_2_8_51_1","doi-asserted-by":"publisher","DOI":"10.1117\/12.3026975"},{"key":"e_1_2_8_52_1","doi-asserted-by":"crossref","unstructured":"DustlerM BakicP IkedaDM L\u00e5ngK ZwiggelaarR Realism of mammography tissue patches simulated using perlin noise: a forced choice reading study.Proc. SPIE 11595 Medical Imaging 2021: Physics of Medical Imaging2021;11595:1303\u20131309.","DOI":"10.1117\/12.2582094"},{"key":"e_1_2_8_53_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4718576"},{"key":"e_1_2_8_54_1","doi-asserted-by":"crossref","unstructured":"TomicH DustlerM BakicPR.Towards improved control of breast density in simulated mammograms via Perlin noise parameterization. InMedical Imaging 2026: Physics of Medical Imaging.SPIE;2026:783\u2013787. doi:10.1117\/12.3088024","DOI":"10.1117\/12.3088024"},{"key":"e_1_2_8_55_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.17980"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.70715","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mp.70715","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mp.70715","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,21]],"date-time":"2026-11-21T10:29:03Z","timestamp":1795256943000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1002\/mp.70715"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,21]]},"references-count":54,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["10.1002\/mp.70715"],"URL":"https:\/\/doi.org\/10.1002\/mp.70715","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,21]]},"assertion":[{"value":"2026-03-14","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-11","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-10-21","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70715"}}